Robert Eberle

University of Innsbruck
Country flagAustria

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (5)

Year:

2025

Year:

2024

Occupational shoulder exoskeletons need to provide meaningful torques to achieve the desired support, thereby high pressures can occur within the physical human–machine interface (pHMI) of exoskeletons that may lead to discomfort, pain, or soft tissue injuries. This pilot study investigates the effects of occurring circumferential pressures within the pHMI in three different shoulder exoskeletons on the tissue oxygenation underneath the interfaces in resting position and dynamic use of the exoskeletons in 12 healthy subjects using near-infrared spectroscopy. Similar to standard Vascular Occlusion Tests, the tissue oxygen decreases while wearing the exoskeletons at rest (−2.1 (1.4) %/min). Dynamic use of the exoskeleton enhances the decrease in tissue oxygen (−7.3 (4.1) %/min) significantly and leads to greater resaturation after reopening the interface compared to resting position. This can be a sign of restricted blood supply to the upper extremity while wearing the exoskeleton. The shape and width of the circular interfaces showed no effect on the tissue oxygenation during use. Tissue oxygenation can be established as an additional safety criterion of exoskeletal pHMIs. The design of pHMI of shoulder exoskeletons should be reconsidered, e.g., in terms of open structures or the elasticity of closure straps to avoid occlusion effects.

Year:

2023

Year:

2022

Year:

2022

Collaborators (3)

Robert Weidner

University of Innsbruck

AUSTRIA
View details

Maurice Mohr

University of Innsbruck

AUSTRIA
View details

Dieter Heinrich

Assistant Professor

University of Innsbruck

AUSTRIA
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.