Rubén Gómez Rioja
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (10)
Objectives Contamination of blood samples from patients receiving intravenous fluids is a common error with potential risk to the patient. Algorithms based on the presence of aberrant results have been described but have the limitation that not all infusion fluids have the same composition. Our objective is to develop an algorithm based on the detection of the dilution observed on the analytes not usually included in infusion fluids. Methods A group of 89 cases was selected from samples flagged as contaminated. Contamination was confirmed by reviewing the clinical history and comparing the results with previous and subsequent samples. A control group with similar characteristics was selected. Eleven common biochemical parameters not usually included in infusion fluids and with low intraindividual variability were selected. The dilution in relation to the immediate previous results was calculated for each analyte and a global indicator, defined as the percentage of analytes with significant dilution, was calculated. ROC curves were used to define the cut-off points. Results A cut-off point of 20 % of dilutional effect requiring also a 60 % dilutional ratio achieved a high specificity (95 % CI 91–98 %) with an adequate sensitivity (64 % CI 54–74 %). The Area Under Curve obtained was 0.867 (95 % CI 0.819–0.915). Conclusions Our algorithm based on the global dilutional effect presents a similar sensitivity but greater specificity than the systems based on alarming results. The implementation of this algorithm in the laboratory information systems may facilitate the automated detection of contaminated samples.
Year:
2023
Objectives Most errors in laboratory medicine occur in the pre- and post-analytical phases of the total testing process (TTP). In 2014, the Spanish Society of Laboratory Medicine (SEQC ML ) started the current Preanalytical Phase EQA Programme, with the objective of providing a tool for the improvement of the preanalytical phase. The aim of this study was to review the evolution of quality indicators (QI) and the comparability of established performance specifications (PS) with other EQA programmes. Methods In the SEQC ML programme, participants were asked to register rejections of the main specimens and the causes for rejections. Data collected from 2014 to 2017, and then reviewed biennially (2018–2019), was used to calculate the percentiles; p25, p50, p75, and p90 for every round, and their means were set as PS. These PS were compared with the results of other programmes. Results The evolution of QI results for 2018–2019 period showed general maintenance or improvement, e.g., a significant decrease in the number of serum samples with a haemolytic index ≥0.5 g/L, except for EDTA and citrate samples handle, maybe for an improvement in detection. The comparison with PS for the QI of the IFCC Working Group “Laboratory Errors and Patient Safety” and the Key Incident Management and Monitoring System (KIMMS) programme of the RCPA showed comparable results, supporting the validity of the established specifications. Conclusions The PS obtained are a helpful tool for benchmarking and to identify processes of the preanalytical phase whose improvement should be set as a priority.
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2020
Collaborators (2)
Seán J Costelloe
-
Mercedes Ibarz
-
Make your next move.
Prepare your application
Review drafts before you send them.