Ruslan Hlushchuk
Has grant
Dozent/Head of microCT research group
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Ruslan Hlushchuk is a Dozent and Head of the microCT research group at the University of Bern, Switzerland. His research areas encompass microCT-based vascular imaging, synchrotron microbeam radiotherapy, and anatomical studies related to various medical models. Recent publications include studies on the complexity of meniscus microvasculature and the non-destructive nature of μCT irradiation, among others.
Recent Grants
Grant: Close
Assessment of various implants and materials in regard to bone augmentation and osseointegration of the implants
Open Date: 2022-01-01
Close Date: 2024-12-01
Grant: Close
Microvascular imaging (microangioCT) with µAngiofil at the soft tissue-implant interface
Open Date: 2021-06-01
Close Date: 2022-05-01
Grant: Close
Acquisition of multiscale laboratory nano-CT system
Open Date: 2020-01-01
Close Date: 2020-12-01
Grant: Close
Novel microangioCT contrast agent enables 3D visualization and quantitative evaluation of the tumor vasculature down to the capillary level with the subsequent histological investigation
Open Date: 2015-09-01
Close Date: 2017-08-01
Grant: Close
Zebrafish caudal fin regeneration revisited: a novel time-efficient quantitative in vivo angiogenesis assay
Open Date: 2013-09-01
Close Date: 2014-08-01
Articles (10)
Year:
2025
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Micro‐computed tomography (μCT) is a fast and powerful technology for studying textural, physical, and chemical properties of solid objects in three dimensions. While regularly used for sample documentation and curation, it is often assumed that μCT techniques are essentially nondestructive or at least very little destructive. However, there are very few studies proving or rejecting the assumption of nondestructiveness. Here we study whether X‐ray tomographic imaging affects the noble gas budget of matrix samples from the CV3 carbonaceous chondrite Allende. We irradiated powdered and homogenized matrix samples in the Bruker SkyScan 1272 μCT instrument at three different X‐ray tube acceleration voltages of 30, 70, and 100 keV. By comparing the noble gas concentrations and especially the elemental and isotopic ratios of the irradiated samples with data for two non‐irradiated aliquots, we found no significant differences. Our study therefore demonstrates that X‐ray tomographic imaging has no measurable effect on the noble gas budget and can therefore safely be used for sample characterization prior to noble gas studies.
Year:
2023
Year:
2023
Collaborators (6)
Sabine Kaessmeyer
University of Bern
Nadia Mercader
Full Professor
University of Bern
Ingo Leya
-
Ole Seehausen
-
Karl Jacobs
Vrije Universiteit Amsterdam
Mathieu de Preux
University of Bern
Make your next move.
Prepare your application
Review drafts before you send them.