Ryan A. Koppes
Assistant Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
About
Ryan A. Koppes is an Assistant Professor in the Department of Chemical Engineering at Northeastern University, located in Boston, MA, USA. His research focuses on the intersection of neurobiology and engineering, particularly in the areas of neurite outgrowth modulation, enteric neuron excitability, and barrier function monitoring. Recent publications highlight his work on magnetic stimulation, microphysiological systems, and the influence of cell composition on biological processes.
Articles (16)
Year:
2026
Microphysiological systems hold great potential for fundamental discovery and accelerating the drug discovery pipeline through simplifying complex tissues to their first principles and enabling real‐time, high‐resolution monitoring. Hydrophilic biomaterials, such as hydrogels, are important for microphysiological system innovations due to their ability to emulate the native extracellular matrix and tunable mechanical properties. Furthermore, hydrogels can be tailored to improve tissue maturity as well as the efficacy of instrumentation. However, many biopolymers are non‐conductive, presenting complications for modeling excitable tissue environments like the heart. In this work, we show that an 8% (w/v) Gelatin Methacryloyl (GelMA) + 3.5% (v/v) Choline Acrylate hydrogel, nicknamed Gel‐Amin, can amplify extracellular voltage recordings from a culture of cardiomyocytes (CMs) from commercial microelectrode arrays. Our laser‐cut and assembly method for manufacturing 3D microphysiological systems allowed direct comparisons of CM contractile activity in Gel‐Amin compared to control GelMA cultures in a single system. This innovative material supported in vitro CM cultures with improved synchronicity and greater signal‐to‐noise ratios (SNRs), suggesting potential improvements over conventional biomaterial limitations. Here, we developed a cost‐effective in vitro cardiac tissue model that allows real‐time electrical activity monitoring.
Year:
2026
Year:
2026
Objective . The use of conductive materials for aiding peripheral nerve regeneration is a promising method to recapitulate native conductance of nerve tissue and facilitate the delivery of exogeneous stimulation for enhanced recovery. This study systematically investigated the effects of applying electrical (ES) or magnetic stimulation (MS) to neurons within new ionically conductive hydrogels. Approach . The material properties of ionically conductive Gel-Amin hydrogels (Gelatin methacryloyl (GelMA) + Choline acrylate) were compared to those of GelMA hydrogels. Neonatal rat dorsal root ganglia (DRG) were encapsulated in both hydrogel formulations, subjected to ES or MS, and evaluated for differences in neuronal extension. Peripheral glia, Schwann cells (SCs), were subjected to the same stimuli and their secretion of various neurotrophic analytes were investigated. Main results . Gel-Amin hydrogels are 4x more ionically conductive than GelMA hydrogels. The application of electrical stimulation to the encapsulated cells led to a significant decrease (76%) in DRG outgrowth when encapsulated in GelMA versus the Gel-Amin hydrogel. In contrast, MS led to directional neurite extension in a direction perpendicular to the magnetic field gradient. Significance . We present here the first report of a controlled, direct comparison of ES and MS on whole DRG in synthetic materials. The combination of ES and MS decreased total neurite outgrowth but led to more directional growth. Aspects of the material and type of stimuli were noted to reduce several cytokine secretion levels from primary SC cultures. These results highlight the importance of understanding material and biophysical interactions to enhance peripheral nerve regeneration.
Year:
2025
Neurosensory circuits of the gastrointestinal tract sense microbial and nutrient changes in the gut; however, studying these circuits in vivo is hindered by invasive techniques and ethical concerns. Here, an in vitro model of enteroendocrine cells (EECs) and calcium reporting enteric neurons (ENs) is established and validated for functional signaling. Both mechanical and sucrose stimulation of co‐cultures increased the percentage of neurons undergoing a calcium flux, indicating an action potential. Neuronal activation is blocked with either a piezo or insulin receptor blocker. At baseline, a flow only stimulus elicited 51.9% of neurons to activate in co‐culture, which is decreased to 15.1% with a piezo blocker. Piezo blocked and sucrose stimulated EECs increased neuronal activation to 43.9%, and an insulin blocker reduced response to 12.4%. Since a cell line is used to model the EEC in the previous experiments, primary rat duodenal epithelium enriched for EECs are also stimulated and found to produced measurable insulin. This work shows the ability of EECs to produce insulin and for ENs to sense insulin. These results inspire further work on how insulin production outside the pancreas effects diabetes, insulin as a neurotransmitter, and exploration of additional nutritional and microbiotic stimuli on enteroendocrine‐to‐neuronal signaling.
Year:
2025
Axonal growth is heavily influenced by topography and biophysical stimuli including magnetic and electrical fields. Despite extensive investigation, the degree of influence and the underlying genetic mechanisms remain poorly understood. Here, a novel approach to guide neurite growth is undertaken using an innovative ferromagnetic composite material – glass‐coated magnetic microwire – to furnish a synergistic combination of magnetic and topographical cues. Whole rat dorsal root ganglia (DRG) are cultured under five different conditions: control, static magnetic field, magnetic microwire, static magnetic field + glass fiber, and static magnetic field + magnetic microwire. DRG outgrowth responses under each condition, including total neurite outgrowth and directionality, are compared. The combination of both magnetic stimulation and topography significantly increases total neurite outgrowth compared to the controls. The combination of magnetic stimulation and magnetic microwire lead to a strong directional bias of growth along the microwire, double what is observed with the glass fiber. Next generation RNA sequencing of DRG exposed to static magnetic field + magnetic microwire reveals the downregulation of genes relating to the immune response, interleukin signaling, and signal transduction. These results set the stage for contemplating future biophysical stimulation for axonal guidance and improved understanding of material‐tissue interactions.
Year:
2025
Our engineered fiber optic-based sensing platform was validated for spatiotemporal monitoring of barrier function in our in-house fabricated gut-on-a-chip, offering a non-invasive approach for characterizing the on-chip microenvironment.
Year:
2025
Several recent advances in microphysiological systems (MPSs) or organ-on-chip technology have demonstrated its potential for replacing traditional in vitro and animal models in the coming years. Despite the physiological relevance and cost-effectiveness of organ chips, there are several hurdles that must be overcome for widespread adoption for biological studies. Many shortcomings of manufacturing and scalability have been overcome by a transition from PDMS to thermoplastics. However, challenges have arisen in these sealed, brittle systems related to end-point tissue analyses, harvest, and high-resolution imaging, which is particularly difficult for multi-layer organ chips. Here, we present low-cost organ chips that are fluidically sealed but demountable, fabricated using a cut-and-assemble method without the need for cleanroom technologies. We have validated the capabilities of this method by demonstrating the culture of human aortic smooth muscle cells and induced pluripotent stem cell-derived neural cells, encapsulated in gelatin methacryloyl (GelMA) hydrogel on chip, for up to 27 days. The 3D culture layer of the organ chip was removed, and high-resolution images were obtained via immunostaining. Furthermore, these organ chips facilitate rapid redesign and manufacture for alternative tissue and/or interface systems. To our knowledge, this is the first innervated organ chip with multiple removable cell culture layers, as well as the first humanized nerve-artery model that includes a three-dimensional hydrogel culture. In future work, these unique features of our platform can be utilized for investigating the crosstalk mechanisms between different cell types in co-culture. Impact Statement We present here a new method for fabricating low-cost demountable organ-on-a-chip platforms. This method leverages our recent cut & assemble method for layered 3D organ chips comprised of gas impermeable thermoplastics.
Year:
2025
Microphysiological systems (MPSs) hold great potential for fundamental discovery and accelerating the drug discovery pipeline through simplifying complex tissues to their first principles and enabling real-time, high-resolution monitoring. Hydrophilic biomaterials, such as hydrogels, are important for MPS innovations due to their ability to emulate the native extracellular matrix and tunable mechanical properties. Furthermore, hydrogels can be tailored to improve tissue maturity as well as the efficacy of instrumentation. However, many biopolymers are non-conductive, presenting complications for modeling excitable tissue environments like the heart. In this work, we show that an 8% (w/v) Gelatin Methacryloyl (GelMA) + 3.5% (v/v) Choline Acrylate hydrogel, nicknamed Gel-Amin, can amplify extracellular voltage recordings from a culture of cardiomyocytes (CMs) from commercial microelectrode arrays. Our laser cut and assemble method for manufacturing 3D MPSs allowed direct comparisons of CM signal propagation in Gel-Amin compared to control GelMA cultures in a single system. This innovative material supported in vitro CM cultures with improved synchronicity and greater signal-to-noise ratios (SNRs), suggesting potential improvements over conventional biomaterial limitations. Here, we developed a cost-effective in vitro cardiac tissue model that allows real-time electrical activity monitoring.
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2022
Collaborators (4)
Abigail Koppes
Associate Professor
Northeastern University
Manuel Vazquez Villalabeitia
Professor of Research
Instituto de Ciencia de Materiales de Madrid
Laura Lewis
Professor
Northeastern University
Xiaoyu Zhang
Scientific Associate
Northeastern University
Make your next move.
Prepare your application
Review drafts before you send them.