Shingen Owada
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (5)
Year:
2026
Background We aimed to quantify the incidence of atrial fibrillation (AF) in patients with cryptogenic stroke globally, as well as separately in patients in and outside of Japan, using an implantable loop recorder from a prospective, observational, Reveal LINQ Registry. Methods and Results Patients developing cryptogenic stroke and monitored by implantable loop recorder for searching AF were studied. The primary end point was incidence of AF within 36 months after insertion. Secondary end points were recurrent ischemic stroke/transient ischemic attack and AF‐related treatment strategies. A total of 271 patients (61.6±14.3 years, 170 men, 60 from Japan) were enrolled from 12 countries. AF was detected in 28.2% at 36 months. The median time from enrollment to AF detection was 7.9 months. During the first 12 months, the AF detection rate slope was relatively steeper in the Japanese subgroup versus non‐Japanese patients. However, by 3 years, the cumulative incidence of AF detection did not differ between groups. Age was the only variable associated with AF detection (hazard ratio, 1.05 [95% CI, 1.02–1.07] per year), trending higher in older age groups. Of the 271 patients, 11 (4.1%) developed recurrent ischemic stroke/transient ischemic attack; AF was detected by implantable loop recorder in only 1 of these patients. Patients with detected AF were more commonly taking oral anticoagulation than those without AF at the last follow‐up (64.7% versus 25.3%, P <0.001). Conclusions The rate of AF detection was similar to other studies in stroke populations monitored by implantable loop recorders, including CRYSTAL‐AF (Cryptogenic Stroke and Underlying Atrial Fibrillation), STROKE‐AF (Stroke of Unknown Cause and Underlying Atrial Fibrillation) and PER‐DIEM (Post‐Embolic Rhythm Detection With Implantable Versus External Monitoring). Patients with detected AF more commonly initiated anticoagulation than those without AF.
Year:
2024
Background It is established that pulmonary vein isolation using the POLARx™ (Boston Scientific, Marlborough, MA, USA) cryoballoon is a rapid, safe, and effective approach. The new POLARx™ FIT (Boston Scientific), which is expandable from 28 to 31 mm in diameter, is currently available. However, there is limited evidence available regarding the treatment of atrial fibrillation in this setting. In this article, we report a case series of cryoballoon ablation in patients with atrial fibrillation using POLARx™ FIT. Case summary This case series describes a comparison of obstruction in three patients with pulmonary veins of different shapes and diameters undergoing cryoballoon ablation and pulmonary vein isolation with a 31 mm diameter balloon. Discussion Cryoballoon ablation using the 31 mm mode of POLARx™ FIT has the potential to provide safe and stable pulmonary vein isolation with good occlusion for a variety of pulmonary vein geometries. In this case series, the 31 mm mode of the POLARx™ FIT resulted in better pulmonary vein occlusion than the 28 mm mode in patients with large left atria and large pulmonary veins, including the left common pulmonary vein. This approach may be considered a first-line therapy option of cryoballoon ablation in patients with atrial fibrillation.
Year:
2023
Year:
2020
Year:
2020
Collaborators (11)
Andrea Natale
Docenti di ruolo di Ia fascia
University of Rome Tor Vergata
Ritsushi Kato
-
Teruyuki Hirano
Professor and Chairman
Kyorin University
Hirofumi Tomita
-
Kyoko Soejima
-
Hiroshi Morita
Professor
-
Reisuke Yoshizawa
Assistant professor
Iwate Medical University
Scott Kasner
Professor, Clinician-Educator
University of Pennsylvania
Alpesh N Amin
University of California, Irvine
Yohei Kawasaki
Professor
Chiba University
Teiichi Yamane
-
Make your next move.
Prepare your application
Review drafts before you send them.