Shomei Ryozawa

Country flagJapan

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (8)

Endoscopic sphincterotomy (EST) is challenging for patients with surgically altered anatomy (SAA). The blades of conventional sphincterotomes designed for SAA do not always face the correct direction of EST. We aimed to evaluate the efficacy and safety of a novel rotatable sphincterotome for EST in patients undergoing Roux‐en‐Y gastrectomy during balloon enteroscopy‐assisted endoscopic retrograde cholangiopancreatography (BE‐ERCP). Patients with Roux‐en‐Y gastrectomy who underwent BE‐ERCP and EST using a novel rotatable sphincterotome between April 2024 and February 2025 were analyzed. Overall, 30 patients were attempted EST with a novel rotatable sphincterotome. EST, including adjustment of the blade to the correct incision direction, was successfully performed in all patients. The median time to complete EST was 3 min. Adverse events occurred in one case of mild post‐ERCP pancreatitis. There was no bleeding or perforation associated with EST. No significant differences were observed in the success rate of EST, time to complete EST, or adverse event rate between the experienced endoscopists and trainee fellows. The use of a novel rotatable sphincterotome for EST during BE‐ERCP was technically feasible and safe in patients who underwent Roux‐en‐Y gastrectomy, which may help standardize EST in patients with SAA.

Year:

2025

Objectives Texture and color enhancement imaging (TXI) reportedly improves the identification of the papilla of Vater for selective biliary cannulation compared with white light imaging (WLI). This multicenter study evaluated the efficacy of short‐type single‐balloon enteroscopy (SBE)‐assisted biliary cannulation using a new‐generation image‐enhanced endoscopy processing system equipped with TXI in patients who underwent Roux‐en‐Y gastrectomy. Methods Patients with Roux‐en‐Y gastrectomy with a native papilla, and underwent short SBE‐assisted biliary cannulation during endoscopic retrograde cholangiopancreatography‐related procedures between January 2019 and April 2023 were retrospectively reviewed. Outcomes of biliary cannulation using TXI and WLI were compared. The primary outcome was time to successful biliary cannulation. Results Thirty‐three patients underwent biliary cannulation with TXI and 98 underwent WLI. The biliary cannulation success rates and median time to successful biliary cannulation with TXI and WLI were 93.9% (95% confidence interval [CI] 79.8–99.3%) and 83.7% (95% CI 74.8–90.4%), respectively ( P = 0.14), and 10 min (interquartile range [IQR] 2.5–23.5) and 18 min (IQR 9.75–24), respectively ( P = 0.04). Biliary cannulation with TXI required a shorter cannulation time than that required with WLI. Adverse event rates with TXI and WLI did not differ significantly ( P = 0.58). Multivariate linear regression analysis showed that the use of TXI and short length of oral protrusion were associated with a shorter successful biliary cannulation time. Conclusion Short SBE‐assisted biliary cannulation was effective and safe on TXI in patients who underwent Roux‐en‐Y gastrectomy, and achieved shorter successful biliary cannulation time.

Year:

2024

The consensus‐based TOKYO criteria were proposed as a standardized reporting system for endoscopic transpapillary biliary drainage. The primary objective was to address issues arising from the inconsistent reporting of stent outcomes across studies, which has complicated the comparability and interpretation of study results. However, the original TOKYO criteria were not readily applicable to recent modalities of endoscopic biliary drainage such as biliary drainage based on endoscopic ultrasound or device‐assisted endoscopy. There are increasing opportunities for managing hilar biliary obstruction and benign biliary strictures through endoscopic drainage. Biliary ablation has been introduced to manage benign and malignant biliary strictures. In addition, the prolonged survival times of cancer patients have increased the importance of evaluating overall outcomes during the period requiring endoscopic biliary drainage rather than solely focusing on the patency of the initial stent. Recognizing these unmet needs, a committee has been established within the Japan Gastroenterological Endoscopy Society to revise the TOKYO criteria for current clinical practice. The revised criteria propose not only common reporting items for endoscopic biliary drainage overall, but also items specific to various conditions and interventions. The term “stent‐demanding time” has been defined to encompass the entire duration of endoscopic biliary drainage, during which the overall stent‐related outcomes are evaluated. The revised TOKYO criteria 2024 are expected to facilitate the design and reporting of clinical studies, providing a goal‐oriented approach to the evaluation of endoscopic biliary drainage.

Year:

2024

Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions.Methods: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S).Results: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03).Conclusions: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.

Year:

2024

Year:

2021

Year:

2021

Year:

2021

Year:

2020

Collaborators (15)

Toshio Fujisawa

Associate Professor

Juntendo University

JAPAN
View details

Hiroyuki Isayama

-

JAPAN
View details

Hironari Kato

-

JAPAN
View details

Ichiro Yasuda

Director and Professor

University of Toyama

JAPAN
View details

Mamoru Takenaka

Kindai University Hospital

JAPAN
View details

Yousuke Nakai

University of Tokyo

JAPAN
View details

Saburo Matsubara

Associate Professor

Saitama Medical University

JAPAN
View details

Itaru Naitoh

Nagoya University Graduate School of Medicine

JAPAN
View details

Kazuo Hara

Director

Aichi Cancer Center

JAPAN
View details

Yoshihide Kanno

Sendai City Medical Center

JAPAN
View details

Takao Itoi

-

JAPAN
View details

Hiroshi Kawakami

University of Miyazaki

JAPAN
View details

Hirofumi Kogure

Nihon University School of Medicine

JAPAN
View details

Masayuki Kitano

Professor

Wakayama Medical University

JAPAN
View details

Atsushi Irisawa

Dokkyo Medical University

JAPAN
View details