Sungju Jee
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (10)
Year:
2024
Year:
2023
Cognitive impairment is observed in 12% to 56% of stroke patients, and screening for cognitive impairment is often complex and time-consuming, with results dependent on patient compliance. Therefore, there is a need for an objective method to assess cognitive impairment regardless of patient compliance. Objective evaluation methods include electroencephalogram (EEG) and event-related potential (ERP). This study was conducted to assess intra-tester reliability of resting EEG-based spectral features and auditory/visual P300 latency/amplitude in patients with subacute ischemic stroke. Twenty patients with subacute ischemic stroke were included in the study. The resting EEG and P300 wave using an auditory and visual oddball paradigm were measured at baseline and once again in 24 hours. The following electrode positions (10–20 system) were constantly recorded: F3 (Frontal), Fz, F4, C3 (Central), Cz, C4, P3 (Parietal), Pz, P4. DAR (delta/alpha ratio) and BSI (brain symmetry index) were determined using EEG data. F3 and F4, C3 and C4 and P3 and P4 were switched according to the stroke side and classified as affected hemisphere (AH) and unaffected hemisphere (UH) after the evaluation. In ERP, the amplitude and latency of P300 were obtained. In reliability analysis of EEG-based spectral characteristics, significant reliability was observed for DAR (ICC = 0.447), BSldir (ICC = 0.713) and BSIdir theta (ICC = 0.724) (Table 4). DAR was showed a poor ICC level, and BSIdir and BSIdir theta had a moderate ICC level. Visual P300 latency showed excellent intraclass correlation coefficient (ICC) in several montages (P UH = 0.972, Pz = 0.945). In 6 montages, auditory P300 latency was reliable, while in 9 montages, visual P300 latency was reliable. In 4 montages, auditory P300 amplitude was reliable, while visual P300 amplitude was reliable in 7. The visual P300 was more reliable than the auditory P300. The ICC values for P300 latency were greater than those for amplitude. Therefore, when ERP is performed on subacute stroke patients, visual has higher reliability than auditory.
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2020
Year:
2020
Year:
2020
Collaborators (9)
Min Ho Chun
University of Ulsan College of Medicine
Jae-Young Han
Chonnam National University Medical School
Bong-Keun Jung
Professor
Seoul National University
Park Dae-Sung
Konyang University
Won Kee Chang
Assistant Professor
-
Sora Baek
-
Sung-Hwa Ko
Assistant Professor
Pusan National University School of Medicine
Yeong Wook Kim
Assistant professor
Chungnam National University School of Medicine
Oh Pum Kwon
Seoul National University College of Medicine
Make your next move.
Prepare your application
Review drafts before you send them.