Your Twin learns with you

30% off annual Pro20% off monthly Pro

Ends in00h00m00s

Utsav Shrestha

Scientist I

University of Wisconsin-Madison
Country flagUnited States

Research Interests

Explore related searches

Articles (9)

Year:

2026

Year:

2026

Year:

2025

Year:

2025

Year:

2024

Year:

2024

Year:

2024

R 2 *‐MRI has emerged as a noninvasive alternative to liver biopsy for assessment of hepatic iron content (HIC). Multispectral fat–water R 2 * modeling techniques such as the nonlinear least squares (NLSQ) fitting and autoregressive moving average (ARMA) models have been proposed for the accurate assessment of iron overload by also considering fat, which can otherwise confound R 2 *‐based HIC measurements in conditions of coexisting iron overload and steatosis. However, the R 2 * estimation by these multispectral models has not been systematically investigated for various acquisition methods in iron overload only conditions and across the full clinically relevant range of HICs (0–40 mg Fe/g dry liver weight). The purpose of this study is to evaluate the R 2 * accuracy and precision of multispectral models for various multiecho gradient echo (GRE) and ultrashort echo time (UTE) imaging acquisitions by constructing virtual iron overload models based on true histology and synthesizing MRI signals via Monte Carlo simulations at 1.5 T and 3 T, and comparing their results with monoexponential model and published in vivo R 2 *–HIC calibrations. The signals were synthesized with T E1 = 1.0 ms for GRE and T E1 = 0.1 ms for UTE acquisition for varying echo spacing, Δ T E (0.1, 0.5, 1, 2 ms), and maximum echo time, TE max (2, 4, 6, 10 ms). An iron‐doped phantom study is also conducted to validate the simulation results in experimental GRE ( T E1 = 1.2 ms, Δ T E = 0.72 ms, TE max = 6.24 ms) and UTE ( T E1 = 0.1 ms, Δ T E = 0.5 ms, TE max = 6.1 ms) acquisitions. For GRE acquisitions, the multispectral ARMA and NLSQ models produced higher slopes (0.032–0.035) compared with the monoexponential model and published in vivo R 2 *–HIC calibrations (0.025–0.028). However, for UTE acquisition for shorter echo spacing (≤0.5 ms) and longer maximum echo time, TE max (≥6 ms), the multispectral and monoexponential signal models produced similar R 2 *–HIC slopes (1.5 T, 0.028–0.032; 3 T, 0.014–0.016) and precision values (coefficient of variation < 25%) across the full clinical spectrum of HICs at both 1.5 T and 3 T. The phantom analysis also showed that all signal models demonstrated a significant improvement in R 2 * estimation for UTE acquisition compared with GRE, confirming our simulation findings. Future work should investigate the performance of multispectral fat–water models by simulating liver models in coexisting conditions of iron overload and steatosis for accurate R 2 * and fat quantification.

Year:

2023

Year:

2023

Collaborators (4)

Aaryani Tipirneni‐Sajja

Associate Professor

University of Houston System

UNITED STATES
View details

Cara Morin

Assistant Professor

Cincinnati Children's Hospital Medical Center

UNITED STATES
View details

SOM BISWAS

University of Tennessee Health Science Center

UNITED STATES
View details

Mark Bolding

The University of Alabama

UNITED STATES
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.