Vincent Boer

Has grant

Country flagDenmark

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Recent Grants

Grant: Close

Zoom coils for high resolution MR imaging

Open Date: 2016-01-01

Close Date: 2016-12-31

Articles (9)

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Purpose Accuracy investigation of volumetric navigators for motion correction, with emphasis on geometric EPI distortions at ultrahigh field. Methods High‐resolution Dixon images were collected in different head positions and reconstructed to water, fat, T 2 *, and B 0 maps. Resolution reduction was performed, and the T 2 * and B 0 maps were used to apply effects of TE and EPI distortions to simulate various volumetric water and fat navigators. Registrations of the simulated navigators were compared with registrations of the original high‐resolution images. Results Increased accuracy was observed with increased spatial resolution for non‐EPI navigators. When using EPI, the distortions had a negative effect on registration accuracy, which was most noticeable for high‐resolution navigators. Parallel imaging helped to alleviate those caveats to a certain extent, and 5‐fold acceleration gave close to similar accuracy to non‐EPI in most cases. Shortening the TE by partial Fourier sampling was shown to be mostly beneficial, except for water navigators with long readout durations. The EPI blip direction had an influence on navigator accuracy, and positive blip gradient polarities (yielding mostly image stretching frontally) typically gave the best accuracy for water navigators, whereas no clear recommendation could be made for fat navigators. Generally, fat EPI navigators had lower accuracy than water EPI navigators with otherwise similar parameters. Conclusions Echo planar imaging has been widely used for MRI navigators, but the induced distortions reduce navigator accuracy at ultrahigh field. This study can help protocol optimization and guide the complex tradeoff between resolution and EPI acceleration in navigator parameter setup.

Year:

2022

Purpose Single‐voxel MRS (SV MRS) requires robust volume localization as well as optimized crusher and phase‐cycling schemes to reduce artifacts arising from signal outside the volume of interest. However, due to local magnetic field gradients (B 0 inhomogeneities), signal that was dephased by the crusher gradients during acquisition might rephase, leading to artifacts in the spectrum. Here, we analyzed this mechanism, aiming to identify the source of signals arising from unwanted coherence pathways (spurious signals) in SV MRS from a B 0 map. Methods We investigated all possible coherence pathways associated with imperfect localization in a semi‐localized by adiabatic selective refocusing (semi‐LASER) sequence for potential rephasing of signals arising from unwanted coherence pathways by a local magnetic field gradient. We searched for locations in the B 0 map where the signal dephasing due to external (crusher) and internal (B 0 ) field gradients canceled out. To confirm the mechanism, SV‐MR spectra (TE = 31 ms) and 3D‐CSI data with the same volume localization as the SV experiments were acquired from a phantom and 2 healthy volunteers. Results Our analysis revealed that potential sources of spurious signals were scattered over multiple locations throughout the brain. This was confirmed by 3D‐CSI data. Moreover, we showed that the number of potential locations where spurious signals could originate from monotonically decreases with crusher strength. Conclusion We proposed a method to identify the source of spurious signals in SV 1 H MRS using a B 0 map. This can facilitate MRS sequence design to be less sensitive to experimental artifacts.

Year:

2022

Year:

2021

Year:

2021

Year:

2020

Collaborators (11)

andrew webb

Professor

Leiden University Medical Center

NETHERLANDS
View details

Christoph Juchem

Associate Professor

Columbia University

UNITED STATES
View details

Martin Meyerspeer

Associate Professor

Medical University of Vienna

AUSTRIA
View details

Eugene Polzik

Københavns Universitet

DENMARK
View details

Andrew Maudsley

Professor

University of Miami School of Medicine

UNITED STATES
View details

Hermien E. Kan

-

NETHERLANDS
View details

Esben Thade Petersen

Technical University of Denmark

DENMARK
View details

Itamar Ronen

-

NETHERLANDS
View details

Evita C. Wiegers

-

NETHERLANDS
View details

Kasper Jensen

Assistant Professor

University of Nottingham

UNITED KINGDOM
View details

Hans Stærkind

Københavns Universitet

DENMARK
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.