Yana Biruk
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (10)
Year:
2025
This paper reports a study into the possibility of using LED systems of ultraviolet radiation for air ionization and disinfection of air and indoor surfaces in the presence of people. It has been established that UV LED lamps with 120° opening angles have parameters under which radiation intensity does not exceed 30 J/m2 at distances of 2 meters. Based on experimental data, a methodology for designing the placement of lamps in the room was devised, which meets the requirements of the SBM-2015 standard and the European Directive 2006/25/EU. The use of LED emitters with a total intensity of up to 25 J/m2 increases the concentration of aero ions. The background concentrations were 140‒180 cm-3 (positive) and 160‒190 cm-3 (negative). The minimum permissible level is 500 cm-3. As a result of irradiation, the concentrations were 1100‒1460 cm-3 (positive) and 1260‒1470 cm-3 (negative). The influence of the recirculator-air purifier on the concentration of aero ions has not been established. The ionization process began immediately after turning on the irradiation systems in the entire volume of the premises (4‒5 meters from the source). The dynamic equilibrium of aero ion concentrations was established within 10‒15 minutes after the irradiation was switched on. The presence of a large number of people (up to 0.97 m2 per person) did not affect the concentration of aero ions. Under the combined effect of ultraviolet radiation and a recirculator-air purifier, the number of mold fungi colonies decreased by 20 times. Under the influence of only ultraviolet radiation – by 2.3 times. The decrease in the number of microbes under the combined effect was 1.6 times, and under the effect of only ultraviolet radiation – 2.8 times
Year:
2023
Year:
2023
A set of measures and means to control the electromagnetic situation of the environment in the territories of urban development, in buildings and individual premises has been substantiated and developed. The simulation tools show the ability to rationalize the parameters of overhead lines with voltages of 220 kV and below, which will reduce the electromagnetic load in the territories. Modeling the propagation of fields from underground high-voltage lines has established that the values of magnetic fields compared to overhead lines are lower up to 30 times. Models of propagation of electromagnetic fields of very high and ultrahigh frequency were built. Sources of electromagnetic fields of non-production origin in industrial buildings have been investigated. Uncompensated currents in power networks with nonlinear electric consumers generate magnetic fields by induction of 0.35−1.20 μT, which exceeds the maximum permissible levels of operation of computer equipment. Leakage currents on grounded metal structures generate magnetic fields with 1.52−6.75 μT. Simulation of the propagation of electric and magnetic fields of components of personal computers of controlled ranges according to the MPRII standard was carried out. Models of propagation of the magnetic field of industrial frequency around electric motors and generators with their cross sections were built. On the basis of such models, design schemes for placing equipment in production areas are selected or places of safe stay and movement of personnel are selected. The expediency of using shielding to reduce field levels to safe values due to coating surfaces with liquid protective mixtures was shown. Metal-containing composition based on water-dispersion paint makes it possible to reduce the level of magnetic field of industrial frequency by 2.5−2.6 times, electric field by 1.6−1.7 times, electromagnetic field of industrial frequency – by 1.2−1.3 times.
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2021
Collaborators (2)
Oksana Tykhenko
Doctor of Engineering Sciences, Professor
-
Larysa Levchenko
Professor
national technical university of ukraine “igor sikorsky kyiv polytechnic institute”
Make your next move.
Prepare your application
Review drafts before you send them.