Yinching Chen
Assistant Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (9)
Year:
2025
Objective . Most methods for partial volume correction (PVC) of positron emission tomography (PET) data employ anatomical segmentation of images into regions of interest. This approach is not optimal for exploratory functional imaging beyond regional hypotheses. Here, we describe a novel method for unbiased voxel-wise PVC. Approach. B-spline basis functions were combined with geometric transfer matrices to enable a method (bsGTM) that provides PVC or alternatively provides smoothing with minimal regional crosstalk. The efficacy of the proposed method was evaluated using Monte Carlo simulations, human PET data, and murine functional PET data. Main results. In simulations, bsGTM provided recovery of partial volume signal loss comparable to iterative deconvolution, while demonstrating superior resilience to noise. In a real murine PET dataset, bsGTM yielded much higher sensitivity for detecting amphetamine-induced reduction of [ 11 C]raclopride binding potential. In human PET data, bsGTM smoothing enabled increased signal-to-noise ratios with less degradation of binding potentials relative to Gaussian convolution or non-local means. Significance. bsGTM offers improved performance for PVC relative to iterative deconvolution, the current method of choice for voxel-wise PVC, especially in the common PET regime of low signal-to-noise ratio. The new method provides an anatomically unbiased way to compensate partial volume errors in cases where anatomical segmentation is unavailable or of questionable relevance or accuracy.
Year:
2024
Background Aging‐associated left ventricular dysfunction promotes cardiopulmonary fibrogenic remodeling, Group 2 pulmonary hypertension (PH), and right ventricular failure. At the time of diagnosis, cardiac function has declined, and cardiopulmonary fibrosis has often developed. Here, we sought to develop a molecular positron emission tomography (PET)–magnetic resonance imaging (MRI) protocol to detect both cardiopulmonary fibrosis and fibrotic disease activity in a left ventricular dysfunction model. Methods and Results Left ventricular dysfunction was induced by transverse aortic constriction (TAC) in 6‐month‐old senescence‐accelerated prone mice, a subset of mice that received sham surgery. Three weeks after surgery, mice underwent simultaneous PET‐MRI at 4.7 T. Collagen‐targeted PET and fibrogenesis magnetic resonance (MR) probes were intravenously administered. PET signal was computed as myocardium‐ or lung‐to‐muscle ratio. Percent signal intensity increase and Δ lung‐to‐muscle ratio were computed from the pre‐/postinjection magnetic resonance images. Elevated allysine in the heart ( P =0.02) and lungs ( P =0.17) of TAC mice corresponded to an increase in myocardial magnetic resonance imaging percent signal intensity increase ( P <0.0001) and Δlung‐to‐muscle ratio ( P <0.0001). Hydroxyproline in the heart ( P <0.0001) and lungs ( P <0.01) were elevated in TAC mice, which corresponded to an increase in heart (myocardium‐to‐muscle ratio, P =0.02) and lung (lung‐to‐muscle ratio, P <0.001) PET measurements. Pressure‐volume loop and echocardiography demonstrated adverse left ventricular remodeling, function, and increased right ventricular systolic pressure in TAC mice. Conclusions Administration of collagen‐targeted PET and allysine‐targeted MR probes led to elevated PET–magnetic resonance imaging signals in the myocardium and lungs of TAC mice. The study demonstrates the potential to detect fibrosis and fibrogenesis in cardiopulmonary disease through a dual molecular PET–magnetic resonance imaging protocol.
Year:
2024
Electrocorticography (ECoG) is a critical tool in preclinical neuroscience research for studying global network activity. However, integrating ECoG with functional magnetic resonance imaging (fMRI) has posed challenges, due to metal electrode interference with imaging quality and heating around the metallic electrodes. Here, we introduce recent advancements in ECoG grid development that utilize a polymer-thick film on an organic substrate (PTFOS). PTFOS offers notable advantages over traditional ECoG grids. Firstly, it significantly reduces imaging artifacts, ensuring minimal interference with MR image quality when overlaying brain tissue with PTFOS grids. Secondly, during a 30-min fMRI acquisition, the temperature increase associated with PTFOS grids is remarkably low, measuring only 0.4 °C. These findings suggest that utilizing ECoG with PTFOS grids has the potential to enhance the safety and efficacy of neurosurgical procedures. By providing clearer imaging results and mitigating risk factors such as excessive heating during MRI scans, PTFOS-based ECoG grids represent a promising advancement in neurosurgical technology. Furthermore, we describe a cutting-edge open-source system designed for simultaneous electrophysiology and fMRI. This system stands out due to its exceptionally low input noise levels (<0.6 V peak-to-peak), robust electromagnetic compatibility (it is suitable for use in MRI environments up to 9.4 teslas), and the inclusion of user-programmable real-time signal-processing capabilities. The open-platform software is a key feature, enabling researchers to swiftly implement and customize real-time signal-processing algorithms to meet specific experimental needs. This innovative system has been successfully utilized in several rodent EEG/fMRI studies, particularly at magnetic field strengths of 4.7 and 9.4 teslas, focusing on the somatosensory system. These studies have allowed for detailed observation of neural activity and responses within this sensory system, providing insights that are critical for advancing our understanding of neurophysiological processes. The versatility and high performance of our system make it an invaluable tool for researchers aiming to integrate and analyze complex datasets from advanced imaging and electrophysiological recordings, ultimately enhancing the depth and scope of neuroscience research.
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Collaborators (4)
Lidia Gomez Cid
Distinguished Professor
Universidad Carlos III de Madrid
Louise Møller Jørgensen
Associate Professor
Copenhagen University Hospital
Iris Yuwen Zhou
Assistant Professor
Massachusetts General Hospital
Giorgio Bonmassar
Associate Professor
Massachusetts General Hospital
Make your next move.
Prepare your application
Review drafts before you send them.