Yoshitaka Bito
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (15)
Year:
2026
Year:
2026
Purpose Diffusion‐weighted imaging (DWI) and intravoxel incoherent motion (IVIM) imaging are well‐established approaches for evaluating cerebrospinal fluid (CSF) flow in subarachnoid and perivascular spaces, and have recently been applied to study ventricular CSF flow. However, DWI does not directly measure flow velocity, and the physical implications of DWI measurements are unclear. This study aimed to provide a theoretical interpretation of the DWI and IVIM imaging of CSF flow velocity fields. Theory The general semi‐analytical form of the signal attenuations caused by fluid flow and the resultant apparent diffusion coefficient were derived from the Bloch–Torrey equation for arbitrary values. Methods The fundamental properties of the signal attenuation in laminar flow velocity fields were investigated. A Monte Carlo simulation of the IVIM parameter estimation was performed based on these signal attenuations, taking background noise into consideration. Results The developed theoretical framework indicates that signal attenuations in DWI detect intravoxel flow velocity standard deviations ranging from approximately 0.1 to 10 mm/s within the range of practical scan parameter settings. The lower bounds of the DWI flow profiles appeared where the flow effect was an order of magnitude lower than the molecular diffusion effects, even when increased. The IVIM fitting parameters reflected the flow effects of the signal attenuations despite an inconsistency with the original IVIM model assumptions. Conclusion The physical implications of signal attenuation in DWI have been theoretically clarified. This framework provides a useful basis for understanding CSF flow dynamics and considering appropriate imaging settings.
Year:
2025
Year:
2025
Purpose To investigate the utility of intracellular enhancement (ICE) technique which suppresses signals from the extracellular space for the evaluation of hepatic function on gadoxetic acid-enhanced hepatobiliary-phase (HBP) images. Methods We subjected 67 patients with suspected neoplastic hepatic lesions to gadoxetic acid-enhanced HBP imaging with and without ICE [i-HBP, conventional-HBP (c-HBP)]. A radiologist calculated the liver/spleen contrast (LSC) [LSC = signal intensity (SI) of liver/SI of spleen]. Receiver-operating analysis was used to evaluate the diagnostic value of the LSC on i-HBP- (i-LSC) and c-HBP images (c-LSC) to differentiate between Child-Pugh classes A and B. Results Of the 67 patients, 57 were in Child-Pugh class A and 10 were in class B. For their differentiation, the area under the curve value of i-LSC was higher than of c-LSC (0.81 vs. 0.68). Conclusions ICE technique can improve the accuracy of estimating hepatic function on HBP images. Graphical abstract
Year:
2025
We aimed to evaluate the accuracy and repeatability of the T 1, T 2*, and proton density (PD) values obtained by quantitative parameter mapping (QPM) using the ISMRM/NIST MRI system phantom and compared them with computer simulations. We compared the relaxation times and PD obtained through QPM with the reference values of the ISMRM/NIST MRI system phantom and conventional methods. Furthermore, we evaluated the presence or absence of influences other than noise in T 1 and T 2* values obtained by QPM by comparing the obtained coefficient of variation (CV) with simulation results. The T 1, T 2*, and PD values by QPM showed a strong correlation with the measured values and the referenced values. The simulated CVs of QPM calculated for each sphere showed similar trends to those of the actual scans.
Year:
2024
Year:
2024
Purpose To evaluate deep learning-reconstructed (DLR)–fluid-attenuated inversion recovery (FLAIR) images generated from undersampled data, compare them with fully sampled and rapidly acquired FLAIR images, and assess their potential for white matter hyperintensity evaluation. Materials and methods We examined 30 patients with white matter hyperintensities, obtaining fully sampled FLAIR images (standard FLAIR, std-FLAIR). We created accelerated FLAIR (acc-FLAIR) images using one-third of the fully sampled data and applied deep learning to generate DLR–FLAIR images. Three neuroradiologists assessed the quality (amount of noise and gray/white matter contrast) in all three image types. The reproducibility of hyperintensities was evaluated by comparing a subset of 100 hyperintensities in acc-FLAIR and DLR–FLAIR images with those in the std-FLAIR images. Quantitatively, similarities and errors of the entire image and the focused regions on white matter hyperintensities in acc-FLAIR and DLR–FLAIR images were measured against std-FLAIR images using structural similarity index measure (SSIM), regional SSIM, normalized root mean square error (NRMSE), and regional NRMSE values. Results All three neuroradiologists evaluated DLR–FLAIR as having significantly less noise and higher image quality scores compared with std-FLAIR and acc-FLAIR ( p < 0.001). All three neuroradiologists assigned significantly higher frontal lobe gray/white matter visibility scores for DLR–FLAIR than for acc-FLAIR ( p < 0.001); two neuroradiologists attributed significantly higher scores for DLR–FLAIR than for std-FLAIR ( p < 0.05). Regarding white matter hyperintensities, all three neuroradiologists significantly preferred DLR–FLAIR ( p < 0.0001). DLR–FLAIR exhibited higher similarity to std-FLAIR in terms of visibility of the hyperintensities, with 97% of the hyperintensities rated as nearly identical or equivalent. Quantitatively, DLR–FLAIR demonstrated significantly higher SSIM and regional SSIM values than acc-FLAIR, with significantly lower NRMSE and regional NRMSE values ( p < 0.0001). Conclusions DLR–FLAIR can reduce scan time and generate images of similar quality to std-FLAIR in patients with white matter hyperintensities. Therefore, DLR–FLAIR may serve as an effective method in traditional magnetic resonance imaging protocols.
Year:
2024
Year:
2024
Purpose Under-sampled scans with iterative reconstruction and high-frequency preserving transform (Us-IRHF) can increase the acquisition speed without degrading the image quality by recovering image information from under-sampled data. We investigate the clinical applicability of high spatial resolution magnetic resonance cholangiopancreatography (MRCP) images without extending the scanning time using Us-IRHF. Methods A slit phantom was scanned with conventional- (without Us-IRHF), Us-IR- (without HF), and Us-IRHF scanning. The matrix size was 320 × 320 for Us-IR- and Us-IRHF- and 288 × 208 for conventional scanning. Modulation transfer function (MTF) focused on the 1.0 lp/cm gauge for each scanning was calculated. For clinical study we acquired respiratory-triggered 3D MRCP scans with and without Us-IRHF (U + -, U − MRCP) in 41 patients. The matrix size was 320 × 320 for U + - and 288 × 208 for U − MRCP. The acquisition time and the relative duct-to-periductal contrast ratios (RCs) for the right- and left intrahepatic bile-, the common bile-, and the main pancreatic duct were recorded. Visualization of each duct and overall image quality was scored on 5-point confidence scales. For visualization of each duct the score ranged from 1 (not visible) to 5 (visible with excellent details), for the image quality, it ranged from 1 (undiagnostic) to 5 (excellent). Superiority for the qualitative visualization score and non-inferiority for the RC values with prespecified margins were assessed. Results Phantom study showed that compared to the conventional- and Us-IR (without HF) images, the MTF for the Us-IRHF image revealed the highest response. For clinical study, the mean acquisition time was 161 s for U + - and 165 s for U − MRCP. For all ducts, the RC value of U + MRCP was non-inferior to U − MRCP and the qualitative visualization score assigned to U + MRCP was superior to U − MRCP. Conclusion Us-IRHF improved the image quality of high spatial resolution MRCP without extending the scanning time.
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Collaborators (9)
Daisuke Kato
Assistant Professor
Hokkaido University
Hiroaki Hayashi
Professor
Kanazawa University
Kohsuke Kudo
Professor
Hokkaido University Graduate School of Medicine
Frank Pilleul
Université Claude Bernard Lyon 1
Yuko Nakamura
National Institutes of Health
Tomohiro Otani
Associate Professor
Osaka University
Olivier Beuf
Director / Senior Research Director
Centre National de la Recherche Scientifique (CNRS)
Shigeki Yamada
Associate Professor
Nagoya University
Noriko Nishioka
Hokkaido University Hospital
Make your next move.
Prepare your application
Review drafts before you send them.