Young-hak SONG
Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (12)
Year:
2026
The thermal energy storage (TES) system in data centers can be applied to cooling energy reduction by utilizing natural cooling sources through free cooling operation when integrated with a water-side economizer (WSE) system. Furthermore, the use of model predictive control (MPC), which has been widely applied to enhance the charging and discharging performance of TES, can further improve cooling energy reduction by refining the free cooling–based charging operation. However, the high nonlinearity of the integrated system, with multiple devices interacting dynamically, reduces prediction accuracy, thereby limiting the effectiveness of MPC. To address this issue, this study developed and applied an MPC strategy combined with the XGBoost machine learning model, known for its superior predictive performance, to a WSE system integrated with TES. The grid-search method was incorporated into the MPC strategy to precisely control the free cooling operation of the integrated system by adjusting the chilled water set-point temperature and TES operating states. Comparative analysis between the proposed AI-based MPC and a conventional rule-based control demonstrated that, under stable indoor temperature conditions during the intermediate season, the chilled water set-point temperature increased by approximately 3-4 °C. As a result, the proposed method achieved 11%, 4.2% respectively reduction in chillers and whole system in total cooling energy use during the intermediate and winter seasons.
Year:
2026
Year:
2025
The energy reduction in chillers has been considered an important factor in the energy efficiency improvements of cooling systems, and water-side free cooling is regarded as the key of chiller free cooling technology. Therefore, this research aims to develop a control methodology for the extension of the free cooling operation time in order to improve the efficiency of water cooling-type chillers based on a WSE (water-side economizer) system for a data center and review the proper control conditions through an energy usage analysis of the entire system. The suggested methodology is an increase in the chilled water supply and return temperature according to the increase in the CARH (Computer Room Air Handler) fan air flow and a decrease in the chilled water flow. A case study was conducted according to the application of control through an EnergyPlus simulation. The results of the simulation show that energy usage was reduced by 8.1% under 120% CRAH fan capacity and 100% chilled water flow conditions. When applying the control plan, the free cooling period was extended according to the increased CRAH fan capacity and decreased chilled water flow. However, the increase in the CRAH fan energy must be considered. Also, in the case of a reduction in the chilled water flow, it is necessary to consider a point that can guarantee the cooling treatment heat rate in the heat exchanger.
Year:
2024
In the aftermath of the COVID-19 pandemic, the urgent need for the rapid deployment of healthcare facilities propelled the rise of modular construction using an infill approach. In these modular, negative-pressure wards, the design of indoor airflow and pressure plays a crucial role in meeting the ventilation strategies required for isolation facilities. Accordingly, this paper focuses on modular negative-pressure wards employing an infill construction method and proposes an appropriate spatial pressure distribution to address the problem of air tightness degradation due to leakage. This study analyzed the indoor airflow and pressure distribution of a unit module corresponding to an infill. It aimed to examine whether the pressure difference with the adjacent room is maintained and to assess its effectiveness in isolating contaminated air. First, the airflow rate of the heating, ventilation, and air conditioning system in the unit module was calculated to ensure that it would meet the performance criteria of the negative-pressure ward. Afterward, based on the calculated rate, the study assessed the airflow and room-specific pressure within a typical floor, encompassing both the unit module and associated nursing support facilities. Here, the airflow in the external corridor of the typical floor was divided into two cases according to the pressure distribution: negative pressure and atmospheric pressure. The calculation results were compared using a computational fluid dynamics tool. The analysis results confirm that the air isolation performance is adequate as the pressure difference between adjacent rooms in the unit module and the typical floor was maintained at 2.5 Pa. Additionally, the indoor airflow in the negative-pressure isolation room formed a stable flow at a slow speed of 0.1–0.2 m/s, minimizing the possibility of air contamination from outside the isolation room. In particular, Case B of the typical floor design proposes a method to optimize the pressure distribution in the modular negative-pressure ward by designing the ventilation flow rate at atmospheric pressure level. Thus, this study emphasizes that atmospheric pressure design is appropriate when designing pressure in areas where negative-pressure control is difficult and can contribute to the design and improvement of similar medical facilities in the future.
Year:
2024
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2021
Year:
2020
Year:
2020