Ziying Yin
Has grant
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Recent Grants
Grant: Close
MRI-based quantitative characterization of impaired myofascial interface properties in myofascial pain syndrome
Open Date: 2022-09-19
Close Date: 2025-08-31
Grant: Open
MRE elastography-based detection of impaired skull-brain decoupling after repetitive subconcussive sports impact
Open Date: 2019-09-15
Close Date: 2030-04-30
Articles (9)
Purpose Active lesion expansion is clinically important because it can indicate disease progression and influence management and treatment planning. However, sequential imaging is often unavailable, and rapid growth can only be inferred from indirect findings such as active perilesional tissue injury. This study aimed to implement and test the feasibility of an MR elastography (MRE)‐based technique for assessing the expansile nature of mass lesions by detecting stiffness changes caused by mechanical strain manifestations in adjacent tissues. Methods A tissue strain mapping (TSM) algorithm was developed using spatial–temporal directional filtering to reveal the presence of perilesional latent strain that is not apparent in conventional MRE inversions. The technical feasibility was tested in tissue‐simulating phantoms containing a mass that was progressively expanded. Preliminary feasibility for clinical application was also demonstrated in representative in vivo examples. Resulting TSM maps were compared with conventional MRE stiffness maps. Results In the phantom experiments, TSM revealed the presence of local strain at the periphery of the expanding mass, with the effect increasing proportionally to the degree of expansion. Conventional MRE did not demonstrate comparable localized stiffening patterns. In vivo examples showed similar perilesional strain features that were not apparent on conventional MRE maps. Conclusion The feasibility of the proposed MRE‐based TSM technique was demonstrated in phantom and preliminary in vivo studies. These findings suggest that the technique is a promising tool for assessing the expansile nature of mass lesions and motivate further development of the TSM processing and exploration of potential clinical applications.
Year:
2026
Background Magnetic resonance elastography (MRE) quantifies tissue viscoelasticity, offering insights into intracranial meningiomas. MRE‐derived parameters, including the storage modulus ( G ') and the magnitude of the complex modulus (| G *|), may aid neurosurgical planning, but their repeatability remains unexplored in brain tumors. Purpose/Hypothesis To evaluate the repeatability of G ' and | G *| in meningiomas, the influence of tumor volume and spatial location on variability, and ranking stability across paired elastograms. Study Type Prospective. Population/Subjects Seventeen paired MRE scans from 16 patients with meningiomas (mean age 64 ± 12 years, 10 females) scheduled for resection. Field Strength/Sequence MRE was performed on a 3 T system using a single‐shot spin‐echo echo‐planar imaging (SE‐EPI) sequence. Assessment Tumors were segmented on contrast‐enhanced T1‐weighted images; distance and volume metrics were extracted. Regions of interest were applied to G ' and | G *| elastograms. Repeatability was evaluated using the coefficient of variation (CV%). Ranking stability was assessed by comparing median G ' or | G *| values. Statistical Tests The difference in CV% was assessed using the Wilcoxon signed rank test. Linear regression assessed the effect of tumor volume and distance from the external occipital protuberance (EOP) on CV%. The Wilcoxon signed‐rank test evaluated ranking stability and scan‐rescan CV%. Statistical significance was defined as p < 0.05. Results The difference in CV% G' (14.89 ± 12.32) and CV% | G *| (13.88 ± 12.60) was not significant ( p = 0.61). Tumor volume inversely correlated with CV% ( G ': β = −0.75 | G *|: β = −0.59). Tumor‐EOP distance had no significant effect ( G ': p = 0.58, | G *|: p = 0.23). Rankings remained stable ( G ': p = 0.82, | G *|: p = 0.71). Data Conclusion MRE‐derived parameters are repeatable in intracranial meningiomas, with G ' and | G *| being equally stable. Larger tumors yielded more consistent estimates. Preserved ranking stability supports the use of MRE in preoperative planning. Evidence Level 2. Technical Efficacy Stage 2.
Year:
2025
Purpose To evaluate the test–retest repeatability of a rapid, free‐breathing two‐dimensional (2D) MR elastography (MRE) technique and to assess the reliability of the liver‐stiffness measurements compared with conventional breath‐hold MREs. Methods Fifteen and 115 participants were enrolled in the technical repeatability and measurement equivalence assessment cohorts, respectively. All participants underwent rapid free‐breathing and conventional breath‐hold 2D MRE (twice in repeatability cohort) on 1.5T scanners. Both methods have four phase offsets over one harmonic motion cycle at 60 Hz; one and 10 cycles were collected and processed in breath‐hold and free‐breathing MREs, respectively. The liver stiffness measurements of free‐breathing (LS F ) and breath‐hold MRE (LS B ) were calculated from manually drawn regions of interest. The repeatability coefficients and Spearman correlation were used to assess technical repeatability and measurement agreement between LS F and LS B . Univariable and multivariable linear regressions were performed to identify potential influencing factors, including age, sex, body mass index, and fat fraction, in the measurement agreement between LS B and LS F . Results The repeatability coefficient of free‐breathing 2D MRE is comparable to breath‐hold MRE (LS F : 20.8%, LS B : 20.4%). LS F showed a strong agreement and significant correlation with LS B (LS F = 1.01 × LS B , ρ = 0.94, p < 0.001). The measurement agreement between LS F and LS B was only significantly affected by sex ( p = 0.047) after adjusting for confounding factors of age, body mass index, and fat fraction. Conclusions The nongated, free‐breathing, multislice 2D MRE technique can provide reliable liver stiffness measurements compared with conventional breath‐hold 2D MRE. It could provide a comfortable alternative method with reliable liver stiffness measurements for patients who have difficulty in suspending respiration.
Year:
2025
Purpose While standard MR elastography (MRE) uses harmonic mechanical waves, there are some applications in which imaging and analysis of transient mechanical motion are of interest. Wavelet MRE has been developed for detecting broadband motion from transient excitation. The goal of this study was to evaluate the accuracy and efficiency of wavelet MRE for transient displacement detection in brain MRE applications. Methods Transient motion was induced in a gel phantom, while MRE images were acquired using bipolar motion‐encoding gradient (MEG) at multiple frequencies (20–200 Hz). Displacements were estimated using (1) combinations of multiple MEGs forming the wavelet MRE and (2) deconvolution from a single MEG. These estimated displacements were used to calculate the MRE phase for each MEG. Correlation ( r 2 ) between the calculated and acquired phases was evaluated. Three healthy volunteers were scanned twice in a clinical scanner using wavelet MRE with an occipital impact. Time‐resolved brain translation, rotation, and maximal principal strain were calculated. Repeatability was assessed both qualitatively and through Pearson correlation. Results Wavelet MRE outperformed standard MRE in displacement estimation, showing higher correlations between calculated and acquired phase, even with fewer phase offsets. In the volunteer study, consistent temporal motion dynamics and spatial maximal principal strain distributions across repeated scans demonstrated the repeatability of wavelet MRE. Conclusion This study validated the accuracy and efficiency of wavelet MRE for broadband motion detection and demonstrated its feasibility and repeatability in vivo. This technique shows promise for advancing our understanding of the injury risks and mechanisms associated with sports‐related head trauma.
Year:
2025
Purpose Abnormal restrictions at myofascial interfaces are a key factor in chronic low back pain (CLBP) with myofascial pain syndrome (MPS), but no established imaging method exists for quantitative assessment. This pilot study evaluated the clinical feasibility of MR elastography (MRE)‐based slip interface imaging (SII) for visualizing myofascial mobility in CLBP‐MPS patients versus age−/sex‐/BMI‐matched healthy participants. A new SII biomarker, maximal normalized displacement discontinuity (), was introduced, and the previously developed normalized octahedral shear strain (NOSS) map was used for comparison. Preliminary assessments of vibration‐frequency effects, repeatability, and group differences in inter‐muscular mobility were conducted. Methods MRE was conducted at 30, 60, and 90 Hz to compare with NOSS for visualizing inter‐muscular slip interfaces at the quadratus lumborum‐erector spinae (QL‐ES) and erector spinae‐multifidus (ES‐M) muscle boundaries at L3‐L4. Repeatability of and NOSS was assessed at 30 Hz (identified as the best‐performing frequency) using within‐subject coefficients of variation and a linear mixed‐effects model from within‐ and between‐day scans. Clinical feasibility was then assessed via Wilcoxon rank‐sum tests in six CLBP‐MPS patients and matched controls. Results at 30 Hz exhibited superior delineation of slip interfaces compared to higher frequencies and NOSS. demonstrated significantly lower variation and better repeatability than NOSS. Healthy participants showed continuous, well‐defined slip interfaces, whereas CLBP‐MPS patients displayed disrupted interfaces with significant mobility reduction at L4 ES‐M. Conclusion SII with lower vibration frequency and map enhances visualization of lower back myofascial mobility and shows potential for assessing differences between healthy individuals and CLBP‐MPS patients.
Year:
2025
Year:
2025
Year:
2025
Brain tumors alter the viscoelastic equilibrium of surrounding tissue, but how these changes shape the mechanics of tumor–brain coupling remains unclear. This study introduces mechanical instability mapping, a voxelwise measure of imbalance between elastic storage and viscous dissipation derived from magnetic resonance elastography (MRE). Twenty-eight patients (15 meningiomas, 13 glioblastomas) were analyzed using standardized 3 T MRE and tumor segmentation. Quantitative descriptors of instability topology—including skeleton length and branch-point densities, and radial persistence (radial-AUC)—were compared across WHO I, WHO II, and glioblastoma groups. Glioblastomas showed diffuse, branched instability fields with significantly higher skeleton and branch-point densities and lower radial-AUC compared with WHO I meningiomas, which exhibited compact, radially coherent patterns; WHO II meningiomas were intermediate. Group-average probability maps confirmed a transition from coherent to fragmented instability with increasing malignancy. These findings demonstrate that peritumoral mechanical topology reflects the degree of viscoelastic coupling at the tumor–brain interface. Instability mapping thereby extends conventional stiffness-based MRE metrics, offering a quantitative framework for assessing interface integrity and heterogeneity that may aid in elasticity-guided treatment strategies and biomechanical phenotyping of brain tumors. Statement of significance Intracranial tumors can disrupt the mechanical equilibrium of the brain, yet how these changes govern tissue deformation, invasion, and surgical behavior remains unclear. Here we introduce mechanical instability mapping —a framework that quantifies the spatial organization of viscoelastic imbalance around tumors using magnetic resonance elastography. Distinct topological patterns of instability differentiate benign from malignant lesions: meningiomas preserve coherent elastic coupling, whereas glioblastomas display fragmented, dissipative fields indicative of invasive, mechanically decoupled growth. These findings identify a new biomechanical signature of tumor–brain interaction and establish instability topology as a quantitative link between imaging, histopathology, and operative mechanics, with potential applications in elasticity-guided neurosurgery, biomechanical phenotyping, and MR-based histopathology.
Year:
2025
Purpose Abnormal adherence at functional myofascial interfaces is hypothesized as an important phenomenon in myofascial pain syndrome. This study aimed to investigate the feasibility of MR elastography (MRE)–based slip interface imaging (SII) to visualize and assess myofascial mobility in healthy volunteers. Methods SII was used to assess local shear strain at functional myofascial interfaces in the flexor digitorum profundus (FDP) and thighs. In the FDP, MRE was performed at 90 Hz vibration to each index, middle, ring, and little finger. Two thigh MRE scans were performed at 40 Hz with knees flexed and extended. The normalized octahedral shear strain (NOSS) maps were calculated to visualize myofascial slip interfaces. The entropy of the probability distribution of the gradient NOSS was computed for the two knee positions at the intermuscular interface between vastus lateralis and vastus intermedius, around rectus femoris, and between vastus intermedius and vastus medialis. Results NOSS map depicted distinct functional slip interfaces in the FDP for each finger. Compared to knee flexion, clearer slip interfaces and larger gradient NOSS entropy at the vastus lateralis–vastus intermedius interface were observed during knee extension, where the quadriceps are not passively stretched. This suggests the optimal position for using SII to visualize myofascial slip interface in skeletal muscles is when muscles are not subjected to any additional force. Conclusion The study demonstrated that MRE‐based SII can visualize and assess myofascial interface mobility in extremities. The results provide a foundation for investigating the hypothesis that myofascial pain syndrome is characterized by changes in the mobility of myofascial interfaces.
Year:
2024
Collaborators (5)
Jan Saip Aunan-Diop
Mayo Clinic
Kristin Zhao
Full Professor
Mayo Clinic
Frantz Rom Poulsen
Consultant/professor
Odense Universitetshospital
Jiahui Li
Assistant professor
Mayo Clinic
Bo Mussmann
Associate professor / 1. amanuensis
OsloMet – Oslo Metropolitan University
Make your next move.
Prepare your application
Review drafts before you send them.