Amirhossein Sanaat
Researcher
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (21)
Introduction Providing tools for comprehensively evaluating scintigraphy images could enhance transthyretin amyloid cardiomyopathy (ATTR-CM) diagnosis. This study aims to automatically detect and score ATTR-CM in total body scintigraphy images using deep learning on multi-tracer, multi-scanner, and multi-center datasets. Methods In the current study, we employed six datasets (from 12 cameras) for various tasks and purposes. Dataset #1 (93 patients, 99m Tc-MDP) was used to develop the 2D-planar segmentation and localization models. Dataset #2 (216 patients, 99m Tc-DPD) was used for the detection (grade 0 vs. grades 1, 2, and 3) and scoring (0 and 1 vs. grades 2 and 3) of ATTR-CM. Datasets #3 (41 patients, 99m Tc-HDP), #4 (53 patients, 99m Tc-PYP), and #5 (129 patients, 99m Tc-DPD) were used as external centers. ATTR-CM detection and scouring were performed by two physicians in each center. Moreover, Dataset #6 consisting of 3215 patients without labels, was employed for retrospective model performance evaluation. Different regions of interest were cropped and fed into the classification model for the detection and scoring of ATTR-CM. Ensembling was performed on the outputs of different models to improve their performance. Model performance was measured by classification accuracy, sensitivity, specificity, and AUC. Grad-CAM and saliency maps were generated to explain the models’ decision-making process. Results In the internal test set, all models for detection and scoring achieved an AUC of more than 0.95 and an F1 score of more than 0.90. For detection in the external dataset, AUCs of 0.93, 0.95, and 1 were achieved for datasets 3, 4, and 5, respectively. For the scoring task, AUCs of 0.95, 0.83, and 0.96 were achieved for these datasets, respectively. In dataset #6, we found ten cases flagged as ATTR-CM by the network. Out of these, four cases were confirmed by a nuclear medicine specialist as possibly having ATTR-CM. GradCam and saliency maps showed that the deep-learning models focused on clinically relevant cardiac areas. Conclusion In the current study, we developed and evaluated a fully automated pipeline to detect and score ATTR-CM using large multi-tracer, multi-scanner, and multi-center datasets, achieving high performance on total body images. This fully automated pipeline could lead to more timely and accurate diagnoses, ultimately improving patient outcomes.
Year:
2025
Deep learning applications have permeated acute ischemic stroke imaging, particularly for stroke lesion segmentation; however, challenges remain, including the need for standardized protocols and test sets, larger public datasets, and performance validation in real-world settings.
Year:
2025
Year:
2025
Introduction Multiplexed PET imaging revolutionized clinical decision-making by simultaneously capturing various radiotracer data in a single scan, enhancing diagnostic accuracy and patient comfort. Through a transformer-based deep learning, this study underscores the potential of advanced imaging techniques to streamline diagnosis and improve patient outcomes. Patients and Methods The research cohort consisted of 120 patients spanning from cognitively unimpaired individuals to those with mild cognitive impairment, dementia, and other mental disorders. Patients underwent various imaging assessments, including 3D T1-weighted MRI, amyloid PET scans using either 18 F-florbetapir (FBP) or 18 F-flutemetamol (FMM), and 18 F-FDG PET. Summed images of FMM/FBP and FDG were used as proxy for simultaneous scanning of 2 different tracers. A SwinUNETR model, a convolution-free transformer architecture, was trained for image translation. The model was trained using mean square error loss function and 5-fold cross-validation. Visual evaluation involved assessing image similarity and amyloid status, comparing synthesized images with actual ones. Statistical analysis was conducted to determine the significance of differences. Results Visual inspection of synthesized images revealed remarkable similarity to reference images across various clinical statuses. The mean centiloid bias for dementia, mild cognitive impairment, and healthy control subjects and for FBP tracers is 15.70 ± 29.78, 0.35 ± 33.68, and 6.52 ± 25.19, respectively, whereas for FMM, it is −6.85 ± 25.02, 4.23 ± 23.78, and 5.71 ± 21.72, respectively. Clinical evaluation by 2 readers further confirmed the model's efficiency, with 97 FBP/FMM and 63 FDG synthesized images (from 120 subjects) found similar to ground truth diagnoses (rank 3), whereas 3 FBP/FMM and 15 FDG synthesized images were considered nonsimilar (rank 1). Promising sensitivity, specificity, and accuracy were achieved in amyloid status assessment based on synthesized images, with an average sensitivity of 95 ± 2.5, specificity of 72.5 ± 12.5, and accuracy of 87.5 ± 2.5. Error distribution analyses provided valuable insights into error levels across brain regions, with most falling between −0.1 and +0.2 SUV ratio. Correlation analyses demonstrated strong associations between actual and synthesized images, particularly for FMM images (FBP: Y = 0.72X + 20.95, R 2 = 0.54; FMM: Y = 0.65X + 22.77, R 2 = 0.77). Conclusions This study demonstrated the potential of a novel convolution-free transformer architecture, SwinUNETR, for synthesizing realistic FDG and FBP/FMM images from summation scans mimicking simultaneous dual-tracer imaging.
Year:
2025
Purpose Low-dose CT protocols are widely used for emergency imaging, follow-ups, and attenuation correction in hybrid PET/CT and SPECT/CT imaging. However, low-dose CT images often suffer from reduced quality depending on acquisition and patient attenuation parameters. Deep learning (DL)-based organ segmentation models are typically trained on high-quality images, with limited dedicated models for noisy CT images. This study aimed to develop a DL pipeline for organ segmentation on ultra-low-dose CT images. Materials and methods 274 CT raw datasets were reconstructed using Siemens ReconCT software with ADMIRE iterative algorithm, generating full-dose (FD-CT) and simulated low-dose (LD-CT) images at 1%, 2%, 5%, and 10% of the original tube current. Existing FD-nnU-Net models segmented 22 organs on FD-CT images, serving as reference masks for training new LD-nnU-Net models using LD-CT images. Three models were trained for bony tissue (6 organs), soft-tissue (15 organs), and body contour segmentation. The segmented masks from LD-CT were compared to FD-CT as standard of reference. External datasets with actual LD-CT images were also segmented and compared. Results FD-nnU-Net performance declined with reduced radiation dose, especially below 10% (5 mAs). LD-nnU-Net achieved average Dice scores of 0.937 ± 0.049 (bony tissues), 0.905 ± 0.117 (soft-tissues), and 0.984 ± 0.023 (body contour). LD models outperformed FD models on external datasets. Conclusion Conventional FD-nnU-Net models performed poorly on LD-CT images. Dedicated LD-nnU-Net models demonstrated superior performance across cross-validation and external evaluations, enabling accurate segmentation of ultra-low-dose CT images. The trained models are available on our GitHub page.
Year:
2025
Year:
2025
Background Cardiac perfusion PET is commonly used to assess ischemia and cardiovascular risk, which enables quantitative measurements of myocardial blood flow (MBF) through kinetic modeling. However, the estimation of kinetic parameters is challenging due to the noisy nature of short dynamic frames and limited sample data points. Purpose This work aimed to investigate the errors in MBF estimation in PET through a simulation study and to evaluate different parameter estimation approaches, including a deep learning (DL) method. Materials and Methods Simulated studies were generated using digital phantoms based on cardiac segmentations from 55 clinical CT images. We employed the irreversible 2‐tissue compartmental model and simulated dynamic 13 N‐ammonia PET scans under both rest and stress conditions (220 cases each). The simulations covered a rest K 1 range of 0.6 to 1.2 and a stress K 1 range of 1.2 to 3.6 (unit: mL/min/g) in the myocardium. A transformer‐based DL model was trained on the simulated dataset to predict parametric images (PIMs) from noisy PET image frames and was validated using 5‐fold cross‐validation. We compared the DL method with the voxel‐wise nonlinear least squares (NLS) fitting applied to the dynamic images, using either Gaussian filter (GF) smoothing (GF‐NLS) or a dynamic nonlocal means (DNLM) algorithm for denoising (DNLM‐NLS). Two patients with coronary CT angiography (CTA) and fractional flow reserve (FFR) were enrolled to test the feasibility of applying DL models on clinical PET data. Results The DL method showed clearer image structures with reduced noise compared to the traditional NLS‐based methods. In terms of mean absolute relative error (MARE), as the rest K 1 values increased from 0.6 to 1.2 mL/min/g, the overall bias in myocardium K 1 estimates decreased from approximately 58% to 45% for the NLS‐based methods while the DL method showed a reduction in MARE from 42% to 18%. For stress data, as the stress K 1 decreased from 3.6 to 1.2 mL/min/g, the MARE increased from 30% to 70% for the GF‐NLS method. In contrast, both the DNLM‐NLS (average: 42%) and the DL methods (average: 20%) demonstrated significantly smaller MARE changes as stress K 1 varied. Regarding the regional mean bias (±standard deviation), the GF‐NLS method had a bias of 6.30% (±8.35%) of rest K 1 , compared to 1.10% (±8.21%) for DNLM‐NLS and 6.28% (±14.05%) for the DL method. For the stress K 1 , the GF‐NLS showed a mean bias of 10.72% (±9.34%) compared to 1.69% (±8.82%) for DNLM‐NLS and −10.55% (±9.81%) for the DL method. Significance This study showed that an increase in the tracer uptake rate (K 1 ) corresponded to improved accuracy and precision in MBF quantification, whereas lower tracer uptake resulted in higher noise in dynamic PET and poorer parameter estimates. Utilizing denoising techniques or DL approaches can mitigate noise‐induced bias in PET parametric imaging.
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Collaborators (9)
Mohammad Saber Azimi
Researcher
Óbuda University
Mark Lubberink
Professor
Uppsala University
BIN JIANG
Stanford University
Nathalie Ginovart
Full Professor
University of Geneva
Maarten G. Lansberg
Professor
Stanford University
isaac shiri
Head of Artificial Intelligence in Cardiovascular Medicine
Groupe INSA
Nancy Pham
Assistant Professor
Stanford University Medical Center
Habib Zaidi
Full Professor & Head of PET Instrumentation and Neuroimaging Lab
University Hospital of Geneva
Andrew Boehringer
University of Geneva
Make your next move.
Prepare your application
Review drafts before you send them.