Andrew Houston
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (2)
Bulk isotope ratios (δ13C-CH4 and δD-CH4) are used as tracers to help determine the contribution of methane (CH4) sources and sinks to the atmospheric burden. The multiply substituted (clumped) isotopologues are now potentially available as additional tracers to improve these distinctions in the global understanding of the CH4 budget. Measurement of Δ13CH3D and Δ12CH2D2, however, is more challenging than measurements of bulk isotopes and requires more advanced instrumentation. Our ongoing project, POLYGRAM (www.polygram.ac.uk), is developing the sampling strategy, sample preparation, mass spectrometry, and modelling work to begin monitoring these new isotopologue ratios.Use of a custom-built automated preconcentrator is a key step in our approach during sample preparation, as HR-IRMS requires ultra-pure CH4 samples to measure the multiply substituted isotopologues. For ambient air studies we obtain 150 ml samples (1 bar) containing around 1% amount fraction of CH4, which can then be easily transported and further purified for final analysis. Importantly this separation technique is automated, free of liquid cryogen, and requires minimal manual intervention. We have also developed the system to be flexible and allow for preparation from any natural sources containing less than 1% CH4. We will present the validation of the method as well as a discussion to support the motivation for future development of monitoring Δ13CH3D and Δ12CH2D2 in the global atmosphere.
Year:
2025
The multiply-substituted isotopologues of methane are of significant interest due to their increased ability to distinguish between methane formation and destruction processes, in comparison to singly-substituted isotopologues, as shown previously by Thiagarajan et al.(2022) and Sivan et al.(2022). Methane isotopologues, unlike the isotopologues of carbon dioxide, do not easily transition towards thermodynamic equilibrium in the atmosphere and therefore, ambient air methane isotopologues, offer constraints on the atmospheric methane sources and sinks (Chung and Arnold, 2021). These processes potentially offer new insight into the causes of variation in methane concentrations in the last two decades.We present developments in the separation of the components of air, using a helium-cooled cryostat. Working on both pre-concentrated air mixtures and laboratory created gas mixtures, we extract methane from the contaminants and other atmospheric gases using the cryostat, applicable to a minimum methane concentration of ~1% (Stolper et al., 2015), then we analyse using a TFS Ultra HR-IRMS. We demonstrate that our cryostat separations successfully extract methane and krypton from laboratory gas mixtures containing the components of atmospheric air, without causing methane fractionation.We also present further developments in measuring and calibrating the isotopologues of methane by high-resolution mass spectrometry. We successfully created thermodynamically equilibrated samples of methane in the 250-500oC range using a nickel catalyst and are working on the 1-250oC range using a γ-Al2O3 catalyst (Eldridge et al., 2019). It is essential to have an extensive calibration curve to best constrain the effects of scale compression on the calculated deltas and therefore reduce sources of further error, hence the extension of this calibration range.Further work will add additional reference and sample points to the absolute reference frame created by the equilibrated samples, optimise the cryogenic/gas chromatographic purification methods for more complex gas mixtures, and optimise the IRMS workflow to reduce the necessary air sample sizes. References:Chung, E. and Arnold, T., 2021. Potential of clumped isotopes in constraining the global atmospheric methane budget. Global Biogeochemical Cycles, 35(10), p.e2020GB006883. Eldridge, D.L., Korol, R., Lloyd, M.K., Turner, A.C., Webb, M.A., Miller III, T.F. and Stolper, D.A., 2019. Comparison of Experimental vs Theoretical Abundances of 13CH3D and 12CH2D2 for Isotopically Equilibrated Systems from 1 to 500 C. ACS Earth and Space Chemistry, 3(12), pp.2747-2764. Liu, Q., Li, J., Jiang, W., Li, Y., Lin, M., Liu, W., Shuai, Y., Zhang, H., Peng, P. and Xiong, Y., 2024. Application of an absolute reference frame for methane clumped-isotope analyses. Chemical Geology, p.121922. Sivan, M., Röckmann, T., Slomp, C.P., van der Veen, C. and Popa, M.E., 2022, May. Isotopic characterization of methane: insights from clumped isotope (13CDH3 and CD2H2) measurements. In EGU General Assembly Conference Abstracts (pp. EGU22-4029). Stolper, D.A., Martini, A.M., Clog, M., Douglas, P.M., Shusta, S.S., Valentine, D.L., Sessions, A.L. and Eiler, J.M., 2015. Distinguishing and understanding thermogenic and biogenic sources of methane using multiply substituted isotopologues. Geochimica et Cosmochimica Acta, 161, pp.219-247. Thiagarajan, N., Pedersen, J.H., Brunstad, H., Rinna, J., Lepland, A. and Eiler, J., 2022. Clumped isotope constraints on the origins of reservoir methane from the Barents Sea. Petroleum Geoscience, 28(2), pp.petgeo2021-037.
Year:
2025
Collaborators (4)
Christopher Rennick
Senior Scientist
National Physical Laboratory
Sara Defratyka
University of Edinburgh
Matthieu Clog
University of Glasgow
Tim Arnold
Associate Professor
Lund University
Make your next move.
Prepare your application
Review drafts before you send them.