Christopher Rennick
Senior Scientist
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (21)
Year:
2026
Year:
2026
Year:
2025
We present a protocol to improve confidence in reported radon activity concentrations, facilitating direct site-to-site comparisons and integration with co-located greenhouse gas (GHG) measurements within a network of three independently managed observatories in the UK. Translating spot measurements of atmospheric GHG amount fractions into regional flux estimates (“top-down” analysis) is usually performed with atmospheric transport models (ATMs), which calculate the sensitivity of regional emissions to changes in observed GHGs at a finite number of locations. However, the uncertainty of regional emissions is closely linked to ATM uncertainties. Radon, emitted naturally from the land surface, can be used as a tracer of atmospheric transport and mixing to independently evaluate the performance of such models. To accomplish this, the radon measurements need to have a comparable precision to the GHGs at the modelled temporal resolution. Australian Nuclear Science and Technology Organisation (ANSTO) dual-flow-loop two-filter radon detectors provide output every 30 min. The measurement accuracy at this temporal resolution depends on the characterization and removal of instrumental background, the calibration procedure, and response time correction. Consequently, unless these steps are standardized, measurement precision may differ between sites. Here we describe standardized approaches regarding (1) instrument maintenance, (2) quality control of the raw data stream, (3) determination and removal of the instrumental background, (4) calibration methods, and (5) response time correction (by deconvolution). Furthermore, we assign uncertainties for each reported 30 min radon estimate (assuming these steps have been followed) and validate the final result through comparison of diurnal and sub-diurnal radon characteristics with co-located GHG measurements. While derived for a network of UK observatories, the proposed standardized protocol could be equally applied to two-filter dual-flow-loop radon observations across larger networks, such as the Integrated Carbon Observation System (ICOS) or the Global Atmosphere Watch (GAW) baseline network.
Year:
2025
To establish robust calibration and measurement capabilities (CMCs) for atmospheric methane (CH 4 ) stable isotope ratios, National Metrology Institutes (NMIs) and Designated Institutes (DIs) need a comprehensive understanding of the underlying measurement techniques, reference materials (RMs), calibration hierarchies, value assignment, uncertainty evaluation, and inter-laboratory comparison activities. This review, developed by the CH 4 Task Team within the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) Gas Analysis Working Group (GAWG) and the Isotope Ratio Working Group (IRWG), provides key insights for developing these capabilities at NMIs/DIs. The World Meteorological Organization (WMO) recommended network compatibility goals for atmospheric methane stable isotope ratio monitoring, expressed as isotope delta values, are 0.02‰ for the stable carbon isotope delta ( δ 13 C) value and 1‰ for the stable hydrogen isotope delta ( δ 2 H) value, with extended targets of 0.2‰ for δ 13 C and 5‰ for δ 2 H. Global inter-laboratory comparisons have revealed offsets of up to 0.5‰ for δ 13 C and 13‰ for δ 2 H measurements, substantially exceeding the WMO targets. To address these discrepancies, steady progress is being made, particularly by expert isotope laboratories, with increasing engagement from NMIs/DIs. Improved measurement techniques and the use of common RMs are bringing measurements closer to the WMO goals. This overview not only reviews the components necessary for establishing NMI/DI CMCs but also provides actionable recommendations to further align global measurements, including the development of standardized protocols, adoption of the VPDB carbon isotope delta scale for atmospheric data harmonization, and international comparison studies to support NMI/DIs in their CMC claims. These actions are critical for achieving long-term consistency and advancing global standards for atmospheric methane stable isotope ratio measurements.
Year:
2025
Satellite remote sensing of global greenhouse gas (GHG) concentrations provides invaluable information about GHG sources and sinks, supporting efficient climate mitigation policies. Recently, the accuracy targets of upcoming GHG satellite missions have become increasingly stringent (2 ppb of CH4; 1 ppm of CO2).Up to now, calibration and traceability of satellite GHG observations relies on two networks of ground-based remote sensing stations: the Total Carbon Column Observing Network (TCCON) and the COllaborative Carbon Column Observing Network (COCCON). Both networks are able to observe the same quantity as the satellite instruments: column-averaged dry-air mole fraction of CO2 and CH4. They also observe N2O, which will likely become another key GHG to be monitored in the future. For traceability, both networks rely on regular aircraft and balloon measurements with in-situ instruments that are traceable to the WMO scale for GHGs.The 24GRD06 MetCTG project aims at greatly improving the accuracy of underlying spectral line parameters for the satellite GHG retrievals and validating the accuracy with in situ and ground-based observations. This will establish traceability to SI and improve data comparability and trustworthiness among GHG satellite missions. It will also improve consistency among ground-based sites and considerably reduce the need for costly aircraft calibrations.The project joins the European metrology community with the TCCON and COCCON communities to provide the best ground-based reference for current and future GHG satellite missions.Acknowledgments: The project (24GRD06 MetCTG) receives funding from the European Partnership on Metrology, co-financed from the European Union’s Horizon Europe Research and Innovation Programme and by the Participating States.
Year:
2025
Bulk isotope ratios (δ13C-CH4 and δD-CH4) are used as tracers to help determine the contribution of methane (CH4) sources and sinks to the atmospheric burden. The multiply substituted (clumped) isotopologues are now potentially available as additional tracers to improve these distinctions in the global understanding of the CH4 budget. Measurement of Δ13CH3D and Δ12CH2D2, however, is more challenging than measurements of bulk isotopes and requires more advanced instrumentation. Our ongoing project, POLYGRAM (www.polygram.ac.uk), is developing the sampling strategy, sample preparation, mass spectrometry, and modelling work to begin monitoring these new isotopologue ratios.Use of a custom-built automated preconcentrator is a key step in our approach during sample preparation, as HR-IRMS requires ultra-pure CH4 samples to measure the multiply substituted isotopologues. For ambient air studies we obtain 150 ml samples (1 bar) containing around 1% amount fraction of CH4, which can then be easily transported and further purified for final analysis. Importantly this separation technique is automated, free of liquid cryogen, and requires minimal manual intervention. We have also developed the system to be flexible and allow for preparation from any natural sources containing less than 1% CH4. We will present the validation of the method as well as a discussion to support the motivation for future development of monitoring Δ13CH3D and Δ12CH2D2 in the global atmosphere.
Year:
2025
Methane (CH4) has a global warming potential 28-36 times that of carbon dioxide over a 100-year period [1]. Different sources of CH4 have distinct isotopic signatures, with CH4 from biological sources having a lighter signature than those from fossil sources [2]. Greenhouse gas (GHG) emissions are typically reported using bottom-up methods (based on data such as emission factors) that are verified using top-down methods (based on atmospheric transport models (ATMs) and observations) which infer fluxes, often through Bayesian methods [3]. Isotope ratio data are generally used in atmospheric models to understand individual contributions of various CH4 sources, globally and regionally. However, there is uncertainty regarding isotopic signatures due to large temporal variabilities and regional specificities [4].Methane isotope ratio source signature information is typically gained through discrete mobile measurement campaigns, with the aim of capturing the emissions directly from the sources, through downwind transection of plumes as closely as possible to the source [5]. These measurements fill databases that are used for atmospheric modelling [2,6,7].Continuous measurements of CH4 isotope ratios are also carried out at from varying sampling heights [7,8,9] (ranging from tens to hundreds of meters) with the lower heights, closer to emissions sources, capturing more local influences and higher heights capturing more regional emissions. While they offer the advantage of being continuous, they are further away from the emission sources, therefore have larger uncertainties.Understanding the information that can be gained from continuous CH4 isotope ratio measurements at different sampling heights and locations will be an important factor to consider when using observational data in inversion frameworks, in terms of accurately quantifying source signatures. We present results of mean isotopic signatures from continuous measurements, resolved using the Keeling approach and compare to modelled data to understand the inferred source contributions.Continuous measurements of CH4 isotope ratios have been carried out at 10 European atmospheric GHG monitoring stations. This study focuses on two sites: Heathfield (an inland, 100 m a.g.l tall tower) and Krakow (an urban, 35 m a.g.l site). We present CH4 isotope ratio datasets from these sites and aim to use them to interpret isotopic signatures in the surrounding areas.[1] IPCC 2021. Cambridge University Press.[2] Sherwood et al. 2017. Earth Syst. Sci. Data. 9, 639-656.[3] Manning et al. 2021. Atmos. Chem. Phys. 21, 12739-12755.[4] Ramsden et al. 2022. Atmos. Chem. Phys. 22, 3911-3929.[5] Bakkaloglu et al. 2022. Atmos. Environ. 276, 119021.[6] Menoud et al. 2020. Tellus B. 72, 1823733.[7] Menoud et al. 2022. Earth Syst. Sci. Data. 14, 4365-4386.[8] Röckmann et al. 2016, Atmos. Chem. Phys. 16, 10469-10487.[9] Rennick et al. 2021. Anal. Chem. 93, 10141-10141.
Year:
2025
Bulk isotopic signatures (δ13C-CH4 and δD-CH4) are widely used for determination of methane source types and relative contributions. For example, these measurements are implemented as additional tracers in top-down studies. However, for some sources, for example certain fossil fuels sources in Europe and waste sector, the bulk isotopic signatures are overlapping, thus some methane sources remain indistinguishable1–4.The multiply substituted (clumped) isotopes can be used as additional tracers to better distinguish methane sources, and potentially, better understand methane sinks. Measurement of methane clumped isotopes, Δ13CH3D and Δ12CH2D2 is more challenging than measurements of bulk isotopes and requires more advanced instruments 3,5–8. Currently, a NERC project called POLYGRAM aims to develop the sample preparation (automated preconcentration) and measurement infrastructure to measure atmospheric air samples using High Resolution - Isotope Ratio Mass Spectrometer (HR-IRMS), to determine clumped isotopes from air samples collected at the world-recognised global monitoring sites at Cape Point, South Africa and station Zeppelin, Svalbard. Moreover, the project also aims to determine the clumped isotopes ratios of methane sources, like wetlands, agriculture or coal mines, as currently clumped isotopes database is constrained.Use of custom-built preconcentrator is a key step in the measurement chain, as HR-IRMS requires ultra-pure methane samples to measure clump isotopes. For ambient air studies, our aim is to obtain, at ambient pressure, a 150 ml sample containing at least 1% of methane from hundreds of litres of ambient air, where CH4 mole fraction is less than 2 ppm. To achieve it, we aim to concentrate methane in our sample by up to 62500 times. Additionally, we develop our preconcentrator to prepare samples containing at least 1% of methane from gas samples containing
Year:
2025
Given its unique properties as a radioactive chemically inert gas, radon can act as a valuable atmospheric tracer, for evaluating the performance of atmospheric transport models to calculate the sources of trace gases to the atmosphere. A radon flux map is the scientific starting point for simulating atmospheric radon concentrations using atmospheric transport models. As such, it is important to assess the available high resolution radon flux maps to ensure that simulated concentrations can be accurately interpreted. The spatial fluxes of radon primarily depend on soil and rock types, while temporal variations are influenced by soil moisture content.The recent advancements in generating two high-resolution radon flux maps for Europe using two different soil moisture reanalysis, GLDAS Noah and the ERA5 maps1, have significantly enhanced our understanding of radon flux dynamics. Yet, the radon flux values diverge notably between these two maps and sometimes these variations can be substantial, with differences as large as the absolute radon flux itself.In our work, two available versions of European radon flux maps are coupled with two Lagranian particle dispersion models – the Met Office’s Numerical Atmospheric Modelling Environment (NAME) and the FLEXPART model – are used to simulate radon concentrations measured at four tall tower sites in the United Kingdom: Heathfield, Ridge Hill, Tacolneston and Weybourne. We calculate the differences between the modelled radon concentrations to the observed radon concentrations at these sites and use this to investigate the sensitivity of two radon flux maps: GLDAS Noah and ERA5. References: 12022: https://doi.org/10.18160/2ST9-3NAD
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Collaborators (22)
Thomas Röckmann
Utrecht University
BIBHASVATA DASGUPTA
Utrecht University
DAVID LOWRY
Reader
Royal Holloway, University of London
Stephan Henne
Senior Scientist
Empa
Jonathan Tennyson
Massey Professor of Phyics
University College London
Karina Adcock
University of East Anglia
Ute Karstens
Lund University
Andrew Houston
University of Glasgow
Dietrich Feist
Deutsches Zentrum für Luft- und Raumfahrt Institut für Physik der Atmosphäre
Yuri Artioli
Marine Ecosystem modeller
Plymouth Marine Laboratory
Sara Defratyka
University of Edinburgh
Andre Butz
Full professor
Heidelberg University
Kieran Stanley
Academic , Senior Research Fellow
University of Bristol
Anita Ganesan
Academic , Professor of Atmospheric Chemistry
University of Bristol
Jia Chen
Technical University of Munich
Matthieu Clog
University of Glasgow
Joseph Pitt
Academic , Senior Research Associate
University of Bristol
Christoph Nehrbass-Ahles
Senior Scientist
National Physical Laboratory
Sangil Lee
Principal Scientist
Korea Research Institute of Standards and Science
Angelina Wenger
University of Bristol
Leigh Fleming
University of East Anglia
Tim Arnold
Associate Professor
Lund University
Make your next move.
Prepare your application
Review drafts before you send them.