Angelo Sassaroli

Tufts University
Country flagUnited States

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (14)

Year:

2026

Year:

2026

Self-calibrating and dual-slope measurements have been used in the field of diffuse optics for robust assessment of absolute values or temporal changes in the optical properties of highly scattering media and biological tissue. These measurements employ optical probes with a minimum of two source positions and a minimum of two detector positions. This work focuses on a quantitative analysis of the impact of errors in these source and detector positions on the assessment of optical properties. We considered linear, trapezoidal, and rectangular optode arrangements and theoretical computations based on diffusion theory for semi-infinite homogeneous media. We found that uncertainties in optodes’ positions may have a greater impact on measurements of absolute scattering versus absorption coefficients. For example, a 4.1% and 19% average error in absolute absorption and scattering, respectively, can be expected by displacing every optode in a linear arrangement by 1 mm in any direction. The impact of optode position errors is typically smaller for measurements of absorption changes. In each geometrical arrangement (linear, trapezoid, rectangular), we identify the direction of the position uncertainty for each optode that has minimal impact on the optical measurements. These results can guide the optimal design of optical probes for self-calibrating and dual-slope measurements.

Year:

2025

The limits of applicability of scaling relations to generate new simulations of photon migration in scattering media by re-scaling an existing Monte Carlo simulation are investigated both for the continuous wave and the time domain case. We analyzed the convergence properties in various scenarios by numerical methods, trying to derive practical guidelines for the judicious use of this approach, as well as a deeper understanding of the physics behind such relations. In the case of scaling of the absorption coefficient, the convergence is always rigorous both for the forward and inverse problems, relying on the derivatives with respect to the absorption coefficient. Also, the regenerated simulation inherits the very same noise of the original Monte Carlo simulation. In the case of scaling of the scattering coefficient, the situation is more critical. For forward problems, even for just a 10% uniform increase in scattering, appreciable deviations are observed whenever a high number of scattering interactions is involved. We tested a practical criterion based on the number of scattering events in the original simulation to judge the convergence of the scaling factors. For inverse problems, the scaling relations provide accurate regenerated simulations apart from the noise level that is increased with respect to the initial simulation, although anyway lower than the noise level obtained by implementing the direct calculation. The results of this study are important whenever an increase of Monte Carlo code throughput is mandatory, e.g. , for fast data analysis of diffuse data, or in machine-learning scenarios, when generating huge datasets is needed.

Year:

2024

Monte Carlo (MC) simulations are the gold standard for describing various transport phenomena and have largely contributed to the understanding of these processes. However, while their implementation for classical transport governed by exponential step‐length distributions is well‐established, widely accepted approaches are still lacking for the more general class of anomalous transport phenomena. In this work, a set of rules for performing MC simulations in anomalous diffusion media is identified, which is also applicable in the case of finite‐size geometries and/or heterogeneous inclusions. The results are presented in the context of radiative transfer, however their implications extend to all types of anomalous transport. The proposed set of rules exhibits full compatibility with the pathlength invariance property for random trajectories, and with the important radiometric concept of fluence. Additionally, it reveals the counter‐intuitive possibility of introducing interfaces between independent subdomains with identical properties, which arise from the fact that non‐exponential step‐length distributions have a “memory” that can in principle be reset when traversing a boundary. These results have far‐reaching consequences not just for the physical interpretation of the corrections required to handle these discontinuities, but also for their experimental verification, due to their expected effects on the observable pathlength distributions.

Year:

2024

Year:

2024

Year:

2024

Real-time and non-invasive measurements of tissue concentrations of oxyhemoglobin (HbO2) and deoxyhemoglobin (HbR) are invaluable for research and clinical use. Frequency-domain near-infrared spectroscopy (FD-NIRS) enables non-invasive measurement of these chromophore concentrations in human tissue. We present a small form factor, dual-wavelength, miniaturized FD-NIRS instrument for absolute optical measurements, built around a custom application-specific integrated circuit and a dual-slope/self-calibrating (DS/SC) probe. The modulation frequency is 55 MHz, and the heterodyning technique was used for intensity and phase readout, with an acquisition rate of 0.7 Hz. The instrument consists of a 14 × 17 cm2 printed circuit board (PCB), a Raspberry Pi 4, an STM32G491 microcontroller, and the DS/SC probe. The DS/SC approach enables this instrument to be selective to deeper tissue and conduct absolute measurements without calibration. The instrument was initially validated using a tissue-mimicking solid phantom, and upon confirming its suitability for in vivo, a vascular occlusion experiment on a human subject was conducted. For the phantom experiments, an average of 0.08° phase noise and 0.10% standard deviation over the mean for the intensities was measured at a source–detector distance of 35 mm. The absorption and reduced scattering coefficients had average precisions (variation of measurement over time) of 0.5% and 0.9%, respectively, on a window of ten frames. Results from the in vivo experiment yielded the expected increase in HbO2 and HbR concentration for all measurement types tested, namely SC, DS intensity, and DS phase.

Year:

2024

Year:

2023

Year:

2023

Year:

2023

Year:

2022

Year:

2021

Year:

2021

Collaborators (4)

Sergio Fantini

Tufts University

UNITED STATES
View details

Giulia Guidetti

Deputy Director, Silklab

Tufts University

UNITED STATES
View details

Antonio Pifferi

Professore Ordinario

Politecnico di Milano

ITALY
View details

Valencia Koomson

Professor

Tufts University

UNITED STATES
View details