Valencia Koomson
Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
About
Valencia Koomson is an Assistant Professor at Tufts University in the United States. Her research encompasses a variety of innovative topics including microfluidics, electrical impedance measurement, and applications of artificial intelligence in health management. Recent publications explore advancements in elastomeric valves, dual-slope near-infrared spectroscopy, and mobile applications for obesity self-management.
Articles (11)
Year:
2026
Year:
2025
A microfluidic device has been designed to electrically measure average intercellular connectivity in a cell monolayer. This proof-of-concept design uses elastomeric microvalves to isolate cells across three microfluidic chambers, creating a direct microscale analog of benchtop sucrose gap physiology rigs. The device operation has been verified for normal rat kidney cells (NRK-49F) using a chemical gap junction blocker, 2-aminoethoxydiphenyl borate (2-APB). At 410 Hz, the system measured an averaged network impedance magnitude between 730 and 930 kΩ and demonstrated the ability to distinguish a significant increase of 6.51 kΩ and 0.464° due to 2-APB perfusion.
Year:
2025
Gap junction connectivity is crucial to intercellular communication and plays a key role in many critical processes in developmental biology. However, direct analysis of gap junction connectivity in populations of developing cells has proven difficult due to the limitations of patch clamp and dye diffusion based technologies. We re-examine a microfluidic technique based on the principle of laminar flow, which aims to electrically measure gap junction connectivity. In the device, the trilaminar flow of a saline sheathed sucrose solution establishes distinct regions of electrical conductivity in the extracellular fluid spanning an NRK-49F cell monolayer. In theory, the sucrose gap created by laminar flow provides sufficient electrical isolation to detect electrical current flows through the gap junctional network. A novel calibration approach is introduced to account for stream width variation in the device, and elastomeric valves are integrated to improve the performance of gap junction blocker assays. Ultimately, however, this approach is shown to be ineffective in detecting changes in gap junction impedance due to the gap junction blocker, 2-APB. A number of challenges associated with the technique are identified and analyzed in depth and important improvements are described for future iterations.
Year:
2025
Year:
2024
Real-time and non-invasive measurements of tissue concentrations of oxyhemoglobin (HbO2) and deoxyhemoglobin (HbR) are invaluable for research and clinical use. Frequency-domain near-infrared spectroscopy (FD-NIRS) enables non-invasive measurement of these chromophore concentrations in human tissue. We present a small form factor, dual-wavelength, miniaturized FD-NIRS instrument for absolute optical measurements, built around a custom application-specific integrated circuit and a dual-slope/self-calibrating (DS/SC) probe. The modulation frequency is 55 MHz, and the heterodyning technique was used for intensity and phase readout, with an acquisition rate of 0.7 Hz. The instrument consists of a 14 × 17 cm2 printed circuit board (PCB), a Raspberry Pi 4, an STM32G491 microcontroller, and the DS/SC probe. The DS/SC approach enables this instrument to be selective to deeper tissue and conduct absolute measurements without calibration. The instrument was initially validated using a tissue-mimicking solid phantom, and upon confirming its suitability for in vivo, a vascular occlusion experiment on a human subject was conducted. For the phantom experiments, an average of 0.08° phase noise and 0.10% standard deviation over the mean for the intensities was measured at a source–detector distance of 35 mm. The absorption and reduced scattering coefficients had average precisions (variation of measurement over time) of 0.5% and 0.9%, respectively, on a window of ten frames. Results from the in vivo experiment yielded the expected increase in HbO2 and HbR concentration for all measurement types tested, namely SC, DS intensity, and DS phase.
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2021
Collaborators (2)
Juanita Mathews
Staff Scientist II
Tufts University
Angelo Sassaroli
Tufts University
Make your next move.
Prepare your application
Review drafts before you send them.