Arturs Meijers
Head of clinical medical physics
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (5)
Year:
2026
Purpose: To present results from the trial radiotherapy quality assurance (RTQA) programme of the centres involved in the randomised phase-III PROton versus photon Therapy for esophageal Cancer – a Trimodality strategy (PROTECT)-trial, investigating the clinical effect of proton therapy (PT) vs. photon therapy (XT) for patients with oesophageal cancer. Materials and methods: The pre-trial RTQA programme consists of benchmark target and organ at risk (OAR) delineations as well as treatment planning cases, a facility questionnaire and beam output audits. Continuous on-trial RTQA with individual case review (ICR) of the first two patients and every fifth patient at each participating site is performed. Patient-specific QA is mandatory for all patients. On-site visits are scheduled after the inclusion of the first two patients at two associated PT and XT sites. Workshops are arranged annually for all PROTECT participants. Results: Fifteen PT/XT sites are enrolled in the trial RTQA programme. Of these, eight PT/XT sites have completed the entire pre-trial RTQA programme. Three sites are actively including patients in the trial. On-trial ICR was performed for 22 patients. For the delineation of targets and OARs, six major and 11 minor variations were reported, and for six patients, there were no remarks. One major and four minor variations were reported for the treatment plans. Three site visits and two annual workshops were completed. Interpretation: A comprehensive RTQA programme was implemented for the PROTECT phase III trial. All centres adhered to guidelines for pre-trial QA. For on-trial QA, major variations were primarily seen for target delineations (< 30%), and no treatment plans required re-optimisation.
Year:
2025
Year:
2024
Background and purpose Rare but severe toxicities of the optic apparatus have been observed after treatment of intracranial tumours with proton therapy. Some adverse events have occurred at unusually low dose levels and are thus difficult to understand considering dose metrics only. When transitioning from double scattering to pencil beam scanning, little consideration was given to increased dose rates observed with the latter delivery paradigm. We explored if dose rate related metrics could provide additional predicting factors for the development of late visual toxicities. Materials and methods Radiation-induced intracranial visual pathway lesions were delineated on MRI for all index cases. Voxel-wise maximum dose rate (MDR) was calculated for 2 patients with observed optic nerve toxicities (CTCAE grade 3 and 4), and 6 similar control cases. Additionally, linear energy transfer (LET) related dose enhancing metrics were investigated. Results For the index cases, which developed toxicities at low dose levels (mean, 50 Gy RBE ), some dose was delivered at higher instantaneous dose rates. While optic structures of non-toxicity cases were exposed to dose rates of up to 1 to 3.2 Gy RBE /s, the pre-chiasmatic optic nerves of the 2 toxicity cases were exposed to dose rates above 3.7 Gy RBE /s. LET-related metrics were not substantially different between the index and non-toxicity cases. Conclusions Our observations reveal large variations in instantaneous dose rates experienced by different volumes within our patient cohort, even when considering the same indications and beam arrangement. High dose rate regions are spatially overlapping with the radiation induced toxicity areas in the follow up images. At this point, it is not feasible to establish causality between exposure to high dose rates and the development of late optic apparatus toxicities due to the low incidence of injury.
Year:
2024
Year:
2023
Collaborators (7)
Jens Zimmerman
Karolinska University Hospital
Hanna Rahbek Mortensen
Associate Professor
Aarhus University
Javier Burguete
Catedrático (Full Professor)
Universidad de Navarra
Ditte Sloth Møller
Head of Medical Physics
Aarhus University
Antje Knopf
Prof for applied data sciences and decision support systems
University of Bern
L. Hoffmann
VIP, Associate Professor
Aarhus University Hospital
Christina T Muijs
Associate professor
University Medical Center Groningen
Make your next move.
Prepare your application
Review drafts before you send them.