Christos Michail
Associate Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
About
Christos Michail is an Assistant Professor at the University of West Attica, Greece. His research primarily focuses on the development and evaluation of scintillators and radiation detectors in medical imaging, with recent publications exploring their properties under X-ray radiation. He has also investigated various aspects of image quality and optimization in nuclear medicine imaging technologies.
Articles (24)
Year:
2026
Year:
2026
Year:
2026
Year:
2026
Year:
2025
Year:
2025
Year:
2025
Cone-beam computed tomography (CBCT) has emerged in recent years as an adequate alternative to mammography and tomosynthesis due to the several advantages over traditional mammography, including its ability to provide 3D images, its reduced radiation dose, and its ability to image dense breasts more effectively and conduct more effective breast compressions, etc. Furthermore, CBCT is capable of providing images with high sensitivity and specificity, allowing a more accurate evaluation, even of dense breasts, where mammography and tomosynthesis may lead to a false diagnosis. Clinical and experimental CBCT systems rely on cesium iodine (CsI:Tl) scintillators for X-ray energy conversion. This study comprises an investigation among different novel CBCT detector technologies, consisting either of scintillators (BGO, LSO:Ce, LYSO:Ce, LuAG:Ce, CaF2:Eu, LaBr3:Ce) or semiconductors (Silicon, CZT) in order to define the optimum detector design for a future experimental setup, dedicated to breast imaging. For this purpose, a micro-CBCT system was adapted, using GATE v9.2.1, consisting of the aforementioned various detection schemes. Two phantom configurations were selected: (a) an aluminum capillary positioned at the center of the field of view in order to calculate the system’s spatial resolution and (b) a breast phantom consisting of spheres of different materials, such that their characteristics are close to the breast composition. Breast phantom contrast-to-noise ratios (CNRs) were extracted from the phantom’s tomographic images. The images were reconstructed with filtered back projection (FBP) and ordered subsets expectation-maximization (OSEM) algorithms. The semiconductors acted satisfactorily in low-density matter, while LYSO:Ce, LaBr3:Ce, and LuAG:Ce presented adequate CNRs for all the different spheres’ densities. The energy converters that are presented in this study were evaluated for their performance against the standard CsI:Tl crystal.
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Collaborators (6)
Ioannis Valais
Professor
University of West Attica
Athanasios Bakas
Assosiate Professor
University of West Attica
Stratos David
Assistant Professor
University of West Attica
Dionysios Linardatos
Professor (Asst)
University of West Attica
Nektarios Kalyvas
Associate Professor & Professor
University of West Attica
Vasiliki Peppa
National and Kapodistrian University of Athens
Make your next move.
Prepare your application
Review drafts before you send them.