Nektarios Kalyvas

Associate Professor & Professor

University of West Attica
Country flagGreece

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

About

Dr. Nektarios Kalyvas is an Associate Professor at the University of West Attica in Greece. His research focuses on advanced scintillator materials and their applications in nuclear medicine and biomedical imaging, as evidenced by his recent articles examining the properties and optimization of various scintillators under x-ray and radiation exposure conditions. He is actively involved in developing novel detector configurations for enhancing image quality in medical imaging technologies.

Articles (26)

Year:

2026

Year:

2026

Year:

2026

Year:

2026

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Cone-beam computed tomography (CBCT) has emerged in recent years as an adequate alternative to mammography and tomosynthesis due to the several advantages over traditional mammography, including its ability to provide 3D images, its reduced radiation dose, and its ability to image dense breasts more effectively and conduct more effective breast compressions, etc. Furthermore, CBCT is capable of providing images with high sensitivity and specificity, allowing a more accurate evaluation, even of dense breasts, where mammography and tomosynthesis may lead to a false diagnosis. Clinical and experimental CBCT systems rely on cesium iodine (CsI:Tl) scintillators for X-ray energy conversion. This study comprises an investigation among different novel CBCT detector technologies, consisting either of scintillators (BGO, LSO:Ce, LYSO:Ce, LuAG:Ce, CaF2:Eu, LaBr3:Ce) or semiconductors (Silicon, CZT) in order to define the optimum detector design for a future experimental setup, dedicated to breast imaging. For this purpose, a micro-CBCT system was adapted, using GATE v9.2.1, consisting of the aforementioned various detection schemes. Two phantom configurations were selected: (a) an aluminum capillary positioned at the center of the field of view in order to calculate the system’s spatial resolution and (b) a breast phantom consisting of spheres of different materials, such that their characteristics are close to the breast composition. Breast phantom contrast-to-noise ratios (CNRs) were extracted from the phantom’s tomographic images. The images were reconstructed with filtered back projection (FBP) and ordered subsets expectation-maximization (OSEM) algorithms. The semiconductors acted satisfactorily in low-density matter, while LYSO:Ce, LaBr3:Ce, and LuAG:Ce presented adequate CNRs for all the different spheres’ densities. The energy converters that are presented in this study were evaluated for their performance against the standard CsI:Tl crystal.

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2020

Year:

2020

Collaborators (5)

Christos Michail

Associate Professor

University of West Attica

GREECE
View details

Ioannis Valais

Professor

University of West Attica

GREECE
View details

Athanasios Bakas

Assosiate Professor

University of West Attica

GREECE
View details

Dionysios Linardatos

Professor (Asst)

University of West Attica

GREECE
View details

Vasiliki Peppa

National and Kapodistrian University of Athens

GREECE
View details