Dzung Dao

Has grant

Professor & Head of Mechanical Engineering Discipline, Director of Mechatronics Engineering Program

Griffith University - Gold Coast Campus
Country flag
Australia

Research Interests

Explore related searches

Contact this professor

LinkedIn
ORCID
Google Scholar
Academic Page

Recent Grants

Grant: Close

A femtosecond laser micromachining facility for a wide range of materials

Open Date: 2019-01-01

Close Date: 2020-01-01

Grant: Close

A tailored suite of instruments to characterize the mechanical, tribological and rheological properties of materials

Open Date: 2019-01-01

Close Date: 2019-12-01

Grant: Close

Advanced Laser Facility

Open Date: 2019-01-01

Close Date: 2019-12-01

Grant: Close

Xe-plasma dual beam for advanced future materials

Open Date: 2018-01-01

Close Date: 2019-01-01

Grant: Close

Magnetofluidic sample handling for enhanced point-of-care diagnosis

Open Date: 2018-01-01

Close Date: 2021-01-01

Articles (17)

Mouthguard-Type Wearable Sensor for Monitoring Salivary Turbidity to Assess Oral Hygiene

Salivary turbidity is a promising indicator for evaluating oral hygiene. This study proposed a wearable mouthguard-type sensor for continuous and unconstrained measurement of salivary turbidity. The sensor evaluated turbidity by measuring the light transmittance of saliva with an LED and a phototransistor sealed inside a double-layered mouthguard. The sensor was also embedded with a Bluetooth wireless module, enabling the wireless measurement of turbidity. The mouthguard materials (polyethylene terephthalate-glycol and ethylene-vinyl acetate) and the wavelength of the LED (405 nm) were experimentally determined to achieve high sensitivity in salivary turbidity measurement. The turbidity quantification characteristic of the proposed sensor was evaluated using a turbidity standard solution, and the sensor was capable of turbidity quantification over a wide dynamic range of 1–4000 FTU (formazine turbidity unit), including reported salivary turbidity (400–800 FTU). In vitro turbidity measurement using a saliva sample showed 553 FTU, which is equivalent to the same sample measured with a spectrophotometer (576 FTU). Moreover, in vivo experiments also showed results equivalent to that measured with a spectrophotometer, and wireless measurement of salivary turbidity was realized using the mouthguard-type sensor. Based on these results, the proposed mouthguard-type sensor has promising potential for the unconstrained continuous evaluation of oral hygiene.

Year:

2024

Collaborators (13)

Koji Toma

Shibaura Institute of Technology

JAPAN

Kenta ICHIKAWA

Assistant Professor

Institute of Science Tokyo

JAPAN

Huaizhong Li

Griffith University

AUSTRALIA

Ninh Dinh

Griffith University

AUSTRALIA

Kohji Mitsubayashi

Tokyo Medical and Dental University

JAPAN

Sima Dimitrijev

Professor

Griffith University

AUSTRALIA

Viet Thanh Nguyen

Associate Lecturer

University of Southern Queensland

AUSTRALIA

Kenta Iitani

Assistant Professor

Tokyo Medical and Dental University

JAPAN

Takeshi Hashishin

Kumamoto University

JAPAN

Toan Dinh

University of Southern Queensland

AUSTRALIA

Takahiro Arakawa

Associate Professor

University of Tokyo

JAPAN

Maksym Rybachuk

Lecturer (Full-time, tenured)

Griffith University

AUSTRALIA

Yong Zhu

Associate Professor

Griffith University

AUSTRALIA
Social connections

How do I reach out?

Sign in for free to see their profile details and contact information.

Meet Kite AI