Ergys Subashi

Associate Professor

The University of Texas MD Anderson Cancer Center
Country flagUnited States
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (4)

Background and Purpose The extraction of quantitative biomarkers on the MR-Linac, which have been shown to be promising in the head and neck, remains a significant gap due to the strict time constraints. Therefore, the purpose of this study was to assess the technical feasibility of magnetic resonance fingerprinting (MRF) to simultaneously extract quantitative T1, T2, R2*, PDFF, and triglyceride composition in the head and neck on the MR-Linac. Materials and Methods Inversion-prepared, multi-echo, golden angle radial, variable flip angle, MRF data were acquired on a 1.5T MR-Linac. The data were corrected for phase errors in the bipolar multi-echo acquisition followed by low rank reconstruction with total variation regularization. A dictionary of signals parameterized by T1/T2 was calculated with an extended phase graph algorithm. Singular images were constructed using a signal subspace from the dictionary and the first singular images were then jointly fit for R2* and PDFF using the off-resonance information from an independent B0 map. The complete set of B0/T2*-corrected fat-water separated water singular images were fit for T1/T2. Triglyceride composition was computed using the multi-echo complex readout. Three phantoms and three healthy volunteers were assessed for accuracy, repeatability, and reproducibility against validated reference sequences across five days using a test-retest setup. Results All coefficients of determination were at least 0.9 against reference sequences in standard phantoms across all quantitative values. The repeatability and reproducibility averaged under 5% in phantoms and under 10% in healthy volunteers. Discussion The proposed MRF acquisition demonstrated the potential to replace the current time-intensive sequences on the 1.5T MR-Linac, thus increasing the adoption of specialized quantitative imaging biomarker approaches at high temporal density in the head and neck. Graphical Abstract

Year:

2025

Background Quantitative mapping of the longitudinal relaxation rate (R1=1/T1) is a major building block for several multiparametric MRI protocols intended for adaptive radiation therapy planning. The implementation of these protocols is challenging in anatomical sites that experience large physiological motion. Purpose To implement and validate a motion-resolved quantitative T1 mapping method on a 1.5T MR-Linac that combines non-Cartesian k-space sampling trajectories with compressed sensing (CS) reconstruction techniques. Methods Four 3D non-Cartesian k-space trajectories were evaluated: radial and stack-of-stars sampling using half- and full-spoke coverage. A variable flip angle acquisition was performed using the spoiled gradient-echo sequence, and T1 mapping was validated using two standard phantoms. Gradient delay timing was optimized empirically to minimize trajectory-induced artifacts. Eight compressed sensing reconstruction strategies were tested using spatial and spatiotemporal regularization operators. Reconstructions were evaluated across multiple implementation parameters and ranked based on spatial resolution, bias, and variability. In vivo studies included one healthy volunteer and one patient undergoing radiotherapy to a target in the kidney. Motion-resolved imaging was performed using respiratory self-gating and phase-sorted reconstruction. Results All non-Cartesian trajectories demonstrated high repeatability and low longitudinal bias in phantom studies, with coefficients of variation below 3.3%. Radial half-spoke sampling achieved the shortest scan times and highest agreement with Cartesian benchmarks. Reconstruction methods incorporating spatiotemporal regularization maintained spatial resolution and quantitative accuracy across undersampling factors up to 20-fold. In human subjects, non-Cartesian T1 mapping provided improved accuracy and reduced variability in mobile abdominal tissues compared to Cartesian acquisitions, particularly in the kidney cortex and medulla, where motion artifacts led to overestimation and higher variance in the reference method. Conclusions T1 mapping using non-Cartesian trajectories and compressed sensing reconstruction is feasible on a 1.5T MR-Linac. The proposed approach enables accurate, motion-resolved quantitative imaging within clinically practical acquisition times. These results support integration of quantitative T1 mapping into adaptive MR-guided radiotherapy workflows and establish a foundation for future development of multiparametric imaging and response-adaptive treatment strategies.

Year:

2025

Objective The purpose of this study was to optimize the technical tradeoffs associated with integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. Recent work has begun to investigate SyntheticMR in the adaptive radiation oncology workflow, however no studies have investigated the variation in acquisition parameters and their relationship to the resulting quantitative maps. Filling this gap will facilitate SyntheticMR’s translation to the adaptive radiation therapy setting in the head and neck due to the reduced bias and increase repeatability and reproducibility of its generated quantitative relaxometric biomarkers. Approach The 2D multi-echo multi-delay (MDME) sequence offered from SyntheticMR was acquired on a MR-Simulation and MR-Linac device in both a phantom and healthy volunteers. Scans were optimized across acceleration factors, slice gaps, acquired voxel sizes, repetition times, echo times, refocusing flip angles, noise-limited gradients, number of slices, and echo train lengths. Quantitative relaxometric T1, T2, and PD maps were tested for accuracy using both correlation and mean absolute bias analysis. Noise profiles were evaluated using the coefficient of variation (CoV) in uniform regions of interest. Main Results The following main findings were reported: (1) noise-limited gradients did not affect the bias or CoV, (2) increasing acceleration factor did not affect bias, but it significantly increased CoV, (3) increasing the number of slices resulted in different significant changes in the quantitative parameters between the MR-Simulator and MR-Linac, (4) reducing the echo train length led to generally reduced bias and CoV, and (5) the repeatability CoV was within previously reported literature values on similar scanners. Significance The behavior of the 2D-MDME sequence from SyntheticMR was characterized across a wide range of acquisition parameters designed for ideal head and neck imaging on both the MR-Simulation and MR-Linac devices in phantom and healthy volunteers. Significant differences existed across several acquisition parameters which should be accounted for when making adjustments for application-specific field-of-views, scan time, and desired ranges of T1, T2, and PD. Application of these findings to the development of efficient head and neck adaptive radiation therapy MRI protocols can enrich the current quantitative biomarker landscape allowing for more informed treatment adaptations.

Year:

2025

Objective The purpose of this study was to investigate the technical feasibility of integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. While SyntheticMR has been investigated for diagnostic applications, no studies have investigated its feasibility and potential for MR-Simulation or MR-Linac workflow. Demonstrating the feasibility of using this technique will facilitate rapid quantitative biomarker extraction which can be leveraged to guide adaptive radiation therapy decision making. Approach Two phantoms, two healthy volunteers, and one patient were scanned using SyntheticMR on the MR-Simulation and MR-Linac devices with scan times between four to six minutes. Images in phantoms and volunteers were conducted in a test/retest protocol. The correlation between measured and reference quantitative T1, T2, and PD values were determined across clinical ranges in the phantom. Distortion was also studied. Contours of head and neck organs-at-risk (OAR) were drawn and applied to extract T1, T2, and PD. These values were plotted against each other, clusters were computed, and their separability significance was determined to evaluate SyntheticMR for differentiating tumor and normal tissue. Main Results The Lin’s Concordance Correlation Coefficient between the measured and phantom reference values was above 0.98 for both the MR-Sim and MR-Linac. No significant levels of distortion were measured. The mean bias between the measured and phantom reference values across repeated scans was below 4% for T1, 7% for T2, and 4% for PD for both the MR-Sim and MR-Linac. For T1 vs. T2 and T1 vs. PD, the GTV contour exhibited perfect purity against neighboring OARs while being 0.7 for T2 vs. PD. All cluster significance levels between the GTV and the nearest OAR, the tongue, using the SigClust method was p < 0.001. Significance The technical feasibility of SyntheticMR was confirmed. Application of this technique to the head and neck adaptive radiation therapy workflow can enrich the current quantitative biomarker landscape.

Year:

2024

Collaborators (10)

R. Jason Stafford

Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Brian Taylor

Associate Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Natalie West

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Jihong Wang

professor/director of imaging

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Dan Ma

Associate Professor

Duke University

UNITED STATES
View details

Jinzhong Yang

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Ken-Pin Hwang

Assistant Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Abdallah Mohamed

Assistant Professor

Baylor College of Medicine

UNITED STATES
View details

Zayne Belal

Assistant Professor

University of Texas Medical Branch

UNITED STATES
View details

Clifton D Fuller

Professor (Tenured)

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details