Zayne Belal

Assistant Professor

University of Texas Medical Branch
Country flagUnited States

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (9)

Year:

2026

Year:

2025

Year:

2025

Year:

2025

Purpose Radiotherapy-induced dysphagia can significantly impair head and neck (H&N) cancer patients’ quality of life. Despite the dose-dependent relationship between radiotherapy and dysphagia, swallowing structures are not routinely contoured due to time and labor demands. We evaluated atlas-based autosegmentation (ABAS) on MRI, identifying the optimal number of atlases required to efficiently and accurately delineate swallowing structures. Methods This study included pre-radiotherapy simulation T2-weighted MRIs from 60 H&N cancer patients enrolled in an IRB-approved observational trial. Scans were acquired on a 1.5T Siemens Aera scanner with H&N immobilization. Swallowing structures, including epiglottis, constrictors, digastric muscles, genioglossus, and others, were manually contoured for 25 atlas patients and 35 test patients. GTV-involved structures were excluded. ABAS was performed with increasing numbers of atlases (1-25) using a random-forest algorithm (ABAS-ADMIRE; Elekta) to determine the optimal atlas count. To mitigate variability from atlas selection, bootstrap resampling was implemented. Dice similarity coefficient (DSC), surface DSC (SDSC), average surface distance (ASD), and 95% Hausdorff distance (HD95) were calculated for each structure. Median computation times were calculated for each atlas count. Hsu’s MCB analysis identified the minimum atlas number statistically equivalent to the best-performing atlas range. Results Across all structures and metrics, Hsu’s analysis demonstrated that 2-4 atlases performed similarly to the best-performing atlas count. All structures except constrictors achieved median DSC>0.75 with ≥2 atlases. Computation times increased linearly with atlas count (range: ∼22-950 seconds for 1-25 atlases). These findings highlight that smaller atlas counts achieve comparable accuracy while significantly improving time efficiency. Conclusion Atlas-based autosegmentation is useful for delineating swallowing muscles in radiotherapy, especially with limited available contoured datasets. Utilizing 2-4 atlases achieves similar geometric accuracy to larger atlas counts, significantly reducing computational time without compromising clinical quality. This balance between efficiency and accuracy supports integration into workflows for better dysphagia prediction and treatment planning.

Year:

2025

Objective The purpose of this study was to optimize the technical tradeoffs associated with integrating the quantitative maps available from SyntheticMR into the head and neck adaptive radiation oncology workflow. Recent work has begun to investigate SyntheticMR in the adaptive radiation oncology workflow, however no studies have investigated the variation in acquisition parameters and their relationship to the resulting quantitative maps. Filling this gap will facilitate SyntheticMR’s translation to the adaptive radiation therapy setting in the head and neck due to the reduced bias and increase repeatability and reproducibility of its generated quantitative relaxometric biomarkers. Approach The 2D multi-echo multi-delay (MDME) sequence offered from SyntheticMR was acquired on a MR-Simulation and MR-Linac device in both a phantom and healthy volunteers. Scans were optimized across acceleration factors, slice gaps, acquired voxel sizes, repetition times, echo times, refocusing flip angles, noise-limited gradients, number of slices, and echo train lengths. Quantitative relaxometric T1, T2, and PD maps were tested for accuracy using both correlation and mean absolute bias analysis. Noise profiles were evaluated using the coefficient of variation (CoV) in uniform regions of interest. Main Results The following main findings were reported: (1) noise-limited gradients did not affect the bias or CoV, (2) increasing acceleration factor did not affect bias, but it significantly increased CoV, (3) increasing the number of slices resulted in different significant changes in the quantitative parameters between the MR-Simulator and MR-Linac, (4) reducing the echo train length led to generally reduced bias and CoV, and (5) the repeatability CoV was within previously reported literature values on similar scanners. Significance The behavior of the 2D-MDME sequence from SyntheticMR was characterized across a wide range of acquisition parameters designed for ideal head and neck imaging on both the MR-Simulation and MR-Linac devices in phantom and healthy volunteers. Significant differences existed across several acquisition parameters which should be accounted for when making adjustments for application-specific field-of-views, scan time, and desired ranges of T1, T2, and PD. Application of these findings to the development of efficient head and neck adaptive radiation therapy MRI protocols can enrich the current quantitative biomarker landscape allowing for more informed treatment adaptations.

Year:

2025

Objective Osteoradionecrosis of the jaw (ORNJ) is a chronic radiation-associated toxicity that lacks standardized classification criteria and treatment guidelines. Understanding early signs of tissue injury could help us better predict, prevent, and conservatively manage ORN. Our primary aims were to identify initial clinically-detected signs of ORN, determine the frequency of imaging-detected ORNJ, and validate the ability to classify cases using the novel system, ClinRad. Study Design A retrospective electronic health record review of 91 patients treated for head and neck cancer at The University of Texas MD Anderson Cancer Center with suspected ORN was performed by an Oral Medicine specialist to identify initial signs of ORN. Patients who received reirradiation to the head and neck or did not have enough evidence of ORN were excluded. A descriptive analysis was performed. Results 51 patients met the inclusion criteria. Half (53%) presented with imaging findings and exposed bone. Imaging findings in the absence of bone exposure were identified in 37%, of which disease progression was observed in 26%. All cases were classifiable using ClinRad. Conclusion Subclinical signs of bony changes consistent with ORN may be evident on imaging without exposed bone, supporting the use of imaging surveillance. ClinRad provided a mechanism to classify all cases at early onset. Data availability statement Anonymized data for the reported analyses is made publicly available on figshare at 10.6084/m9.figshare.28292186. Reporting guideline compliance statement In accordance with the EQUATOR Network (Enhancing the QUAlity and Transparency Of health Research) guidance, we have utilized the RECORD checklist, a guideline for the “REporting of studies Conducted using Observational Routinely-collected health data” (Benchimool El at al., 2015) The RECORD checklist is provided as a Supplementary file and available via 10.6084/m9.figshare.28292219. Data was anonymized in accordance with the EQUATOR guideline “Preparing raw clinical data for publication: guidance for journal editors, authors, and peer reviewers” (Hrynaszkiewicz I et al., 2010).

Year:

2025

Background Currently, a majority of institution-specific automatic MRI-based contouring algorithms are trained, tested, and validated on one contrast weighting (i.e., T2-weighted), however their actual performance within this contrast weighting (i.e., across different repetition times, TR, and echo times, TE) is under-investigated and poorly understood. As a result, external institutions with different scan protocols for the same contrast weighting may experience sub-optimal performance. Purpose The purpose of this study was to develop a method to evaluate the robustness of automatic contouring algorithms to varying MRI contrast weightings. Methods One healthy volunteer and one patient was scanned using SyntheticMR on the MR-Simulation device. The parotid and submandibular glands in these subjects were contoured using an automatic contouring algorithm trained on T2-weighted MRIs. For ground truth manual contours, two radiation oncology residents and one pre-resident physician were recruited and their STAPLE consensus was determined. A total of 216 different MRI TR and TE combinations were simulated across T1-, T2-, and PD-weighted contrast ranges using SyntheticMR’s post-processing software, SyMRI. Comparisons between automatic contouring algorithm contours and the ground truth were determined using the Dice similarity coefficient (DSC) and 95 th percentile Hausdorff distance (HD95). Results Notable differences in the automatic contouring model’s performance were seen across the contrast-weighted range, even within the T2-weighted range. Further, some models even performed as well or better across subsets of the T1-weighted range. The PD-weighted range saw the worst performance. The range of discrepancy in DSC and HD95 exceeded 0.2 and 3.66 mm, respectively, in some structures. In the T2-weighted contrast region where the model was trained, 100%, 40%, 24%, and 57% for the DSC in the left parotid, right parotid, left submandibular, and right submandibular gland, respectively, exceeded interobserver variability. Conclusions This study demonstrates the variable performance of MRI-based automatic contouring algorithms across varying TR and TE combinations. This methodology could be applied in future studies as a method for evaluating model sensitivity, out of distribution detection ability, and performance drift.

Year:

2025

Year:

2023

Collaborators (15)

R. Jason Stafford

Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Weihow Hsue

Assistant Professor

Cornell University

UNITED STATES
View details

Katherine Hutcheson

Associate Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Ergys Subashi

Associate Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Muhammad Walji

Chair and Professor

The University of Texas Health Science Center at Houston

UNITED STATES
View details

Natalie West

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Sudarat Kiat-Amnuay

The University of Texas Health Science Center at Houston

UNITED STATES
View details

Stephen Lai

Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Amy Moreno

Assistant Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Dan Ma

Associate Professor

Duke University

UNITED STATES
View details

Jillian Rigert

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Ken-Pin Hwang

Assistant Professor

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Abdallah Mohamed

Assistant Professor

Baylor College of Medicine

UNITED STATES
View details

Zaphanlene Kaffey

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details

Clifton D Fuller

Professor (Tenured)

The University of Texas MD Anderson Cancer Center

UNITED STATES
View details