Erik Korevaar
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (5)
Objective. Due to the magnetic hysteresis effect, it normally takes more time to switch the energy layer upward compared to downward in proton arc therapy (PAT), e.g. 5.5 s for energy layer switching upwards and 0.7 s for energy layer switching downwards. Therefore, previous studies have focused on reducing the number of energy jumps (NEJ) as a main direction. However, it is possible to reduce the energy layer switching time, for instance, by using magnetic field feedback in the energy layer switching system (ELSS) of the proton therapy system (PTS), especially for small energy jumps. Thus, we propose a new energy selection optimization strategy to improve the treatment delivery efficiency based on a fast ELSS, which allows energy jumps within a pre-defined threshold energy layer optimization (ELO-EJT). Approach. The ELO-EJT algorithm is based on two sequential steps: ELO and plan-quality re-optimization. The ELO problem was solved using the proximal forward–backward splitting method. The optimization problem of plan-quality re-optimization was solved by the alternating direction method of multipliers. Eight clinical cases were tested on the open-source treatment planning system matRad (German Cancer Research Center DKFZ), assessing plan quality and treatment delivery efficiency to evaluate the ELO-EJT algorithm. Main results. The ELO-EJT algorithm could achieve similar plan quality compared with the spot-scanning proton arc therapy _seq algorithm, which is based on the energy layer sorting and re-distribution mechanisms. Meanwhile, it reduces the beam delivery time without the need to limit energy jumps. More specifically, it reduces BDT by 23.93 ± 4.12% (from 123.95 ± 11.94 s to 94.14 ± 8.82 s). Significance. A new ELO strategy could effectively reduce the treatment delivery time by minimizing the NEJ exceeding a threshold NEJ T , which paves the way for the clinical application of spot-scanning PAT.
Year:
2025
Objective. Radiotherapy in nasopharyngeal cancer (NPC) patients presents challenges due to proximity of many anatomical structures to the target volume. Furthermore, inter-fractional changes must be considered to assure target coverage. Proton arc therapy (PAT) potentially reduces healthy tissue dose compared to IMPT and VMAT. The impact of PAT on dose to organs-at-risk (OARs), predicted acute-and late radiation toxicities and robust target coverage to inter-fraction changes in NPC patients were investigated. Approach. Robustly optimized PAT plans were compared to clinical VMAT and IMPT plans for 10 NPC patients treated with 70.00 Gy to the primary target (CTV 7000) and 54.25 Gy to the prophylactic lymph nodal area (CTV 5425). Integral body dose and mean and max in 0.03cc dose ( D mean and max D0.03cc) in OARs were compared. Normal tissue complication probability (NTCP) values for 22 acute and late radiation-induced toxicities were evaluated. A PAT ‘base approach’ and nine PAT planning approaches to improve PAT inter-fraction robust target coverage were investigated. Target coverage was evaluated on in total 54 weekly repeated CT images (rCTs). Main results. PAT integral dose reduced by on average 55% and 15% compared with clinical VMAT and IMPT, respectively. Compared to IMPT, average D mean and max D0.03cc were significantly reduced in all evaluated neurological structures. Compared to IMPT, in the PAT plans D mean was reduced most in the arytenoids, PCM medius and brainstem by on average 8.0 Gy, 6.4 Gy and 6.1 Gy, respectively and all evaluated NTCP’s for both acute and late timepoint were significantly reduced. Compared with IMPT, PAT base approach target coverage on rCTs was worse. Approaches to improve PAT inter-fraction target coverage were successful, while maintaining the reduction in NTCP compared to IMPT. Significance. Compared to IMPT and VMAT, PAT reduces healthy tissue dose and subsequent estimated toxicity risks in NPC patients. PAT planning approaches to improve inter-fraction robustness were employed successfully, while NTCP benefits of PAT were maintained.
Year:
2025
Year:
2023
Year:
2021
Year:
2021
Collaborators (2)
Arjen van der Schaaf
Scientific Staff
University Medical Center Groningen
Christina T Muijs
Associate professor
University Medical Center Groningen
Make your next move.
Prepare your application
Review drafts before you send them.