Essam Elsaed

Teaching and research staff

University of Tampere
Country flagFinland

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (7)

Year:

2026

Year:

2025

Year:

2024

The necessity for greater energy conservation in hydraulic machinery is highlighted by escalating fuel costs and heightened ecological awareness. Utilizing independent metering to enhance the energy utilization of hydraulic actuators is one effective strategy, yet the market is short on efficient reversible proportional valves that can perform this function. For handling modest flow rates up to 150 Liters per minute, the digital hydraulic method utilizing fast direct operated on/off solenoid valves shows promise; however, solutions for managing larger flows remain vague. This research explores the application of pilot-operated solenoid valves in digital hydraulic systems designed for substantial flow volumes. It establishes a model grounded in physical principles to examine how various factors influence the valve reaction speed. A unique valve design was established, derived from an existing valve but with a modified structure. The findings indicate that the pressure difference, viscosity of the fluid and pilot plunger dynamics are crucial determinants of the valve response time. Incorporating a stroke limiter proves significant in harmonizing the response times across valves with varying flow rates, while the traditional methods of deploying serial orifices is deemed unsuitable. A glance from the results shows that at a ΔP of 10 bar, the valve with an 8 mm attached serial orifice has an opening response of 65 ms, while the stroke limited valve achieves 40 ms. This significant advantage slightly narrows at higher pressures, stabilizing at 100 bar. During closing, the stroke limiter is remarkably 60% faster at 10bar, and both configurations settle at 40 ms at 200 bar.

Year:

2024

Digital hydraulics offers advantages over traditional proportional valves but lacks high flow rate performance. This study proposes a solution based on operated on/off valves. The proposed system achieved a flow rate of nearly 350 LPM at nominal operating pressure with a roughly 25 ms fast response time. A novel dual flow solution is also presented and analyzed. These breakthroughs demonstrate the innovative feasibility of implementing pilot-operated, stroke-limited on/off valves in digital hydraulics. The results show that more possible discrete flow rates were achievable using the dual discrete flow method. In conclusion, the grouping of these valves and digital control approach enhances fluid power systems resolution, opening new possibilities for wider adoption, and improved performance in digital hydraulic systems.

Year:

2024

Year:

2023

Year:

2020

Collaborators (1)

Matti Linjama

University of Tampere

FINLAND
View details