Ján Semjon
Research Interests
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (9)
This paper presents the development and validation of a cost-efficient and uncomplicated real-time localization system (RTLS) for use in mobile robotics, specifically within indoor and storage environments. By harnessing ultrasonic waves to measure distances from three beacons, the system provides stable and reliable localization. This method utilizes the time-of-flight (TOF) principle, allowing for accurate distance calculations with simple microcontrollers. The system is designed to update the robot’s position at a frequency of at least 10 times per second, ensuring smooth navigation. Our trilateration-based approach allows for the precise determination of the robot’s position with a notable standard deviation accuracy of up to 15 mm. The aim was to design a simple yet sufficiently accurate system and verify its precision through experimental measurements. The experimental results demonstrate the system’s efficacy and lay a solid foundation for advancing this technology. Furthermore, the cost for the components required to build this indoor localization system (ILS) with three beacons and one tag is remarkably low, under EUR 80.
Year:
2024
Technical solutions based on biological models are the subject of research by a wide range of experts and mainly concern their mechanical use. When designing a suitable actuator, they use the physical methods of biological representatives, of which a large group consists of actuators generally referred to as artificial muscles, while another group uses compressed air as an energy carrier. In order to perform the measurements described in this article, a test mechanism based on the opposing arrangement of a pair of pneumatic muscles was constructed. Measurements on the test mechanism were made at set constant pressures in the range of 0.4 MPa to 0.6 MPa, while at each pressure, measurements were made for the counterload range from 0 N to 107.87 N. The measured values were recorded using a microcontroller and subsequently processed into graphic outputs. As part of the measurements, a comparative measurement of the same opposite arrangement of a pair of linear double-acting pneumatic actuators with a single-sided piston rod was also performed. The experiment and measurements were carried out in order to determine the suitability of using pneumatic artificial muscles in the selected arrangement for the implementation of a mechanism imitating the human arm. The target parameters of the experiment were the reaction speed of the course of force when filling the muscle under load and the reaction of the mechanism to a change in the set pressure in the pneumatic system. The summary of the comparison of the measured results is the content of the discussion in this article.
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2020
Collaborators (5)
Dominik Heczko
VSB - Technical University of Ostrava
Petr Oščádal
VSB - Technical University of Ostrava
Ivan Virgala
-
Peter Marcinko
-
Tomáš Kot
VSB - Technical University of Ostrava
Make your next move.
Prepare your application
Review drafts before you send them.