Marius Keller

University Hospital Tübingen
Country flagGermany

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (10)

Background: Left atrioventricular valve (LAVV) stenosis following an atrioventricular septal defect (AVSD) repair is a rare but potentially life-threatening complication. While echocardiographic quantification of diastolic transvalvular pressure gradients is paramount in the evaluation of a newly corrected valve function, it is hypothesized that these measured gradients are overestimated immediately following a cardiopulmonary bypass (CPB) due to the altered hemodynamics when compared to postoperative valve assessments using awake transthoracic echocardiography (TTE) upon recovery after surgery. Methods: Out of the 72 patients screened for inclusion at a tertiary center, 39 patients undergoing an AVSD repair with both intraoperative transesophageal echocardiograms (TEE, performed immediately after a CPB) and an awake TTE (performed prior to hospital discharge) were retrospectively selected. The mean (MPGs) and peak pressure gradients (PPGs) were quantified using a Doppler echocardiography and other measures of interest were recorded (e.g., a non-invasive surrogate of the cardiac output and index (CI), left ventricular ejection fraction, blood pressures and airway pressures). The variables were analyzed using the paired Student’s t-tests and Spearman’s correlation coefficients. Results: The MPGs were significantly higher in the intraoperative measurements when compared to the awake TTE (3.0 ± 1.2 vs. 2.3 ± 1.1 mmHg; p < 0.01); however, the PPGs did not significantly differ (6.6 ± 2.7 vs. 5.7 ± 2.8 mmHg; p = 0.06). Although the assessed intraoperative heart rates (HRs) were also higher (132 ± 17 vs. 114 ± 21 bpm; p < 0.001), there was no correlation found between the MPG and the HR, or any other parameter of interest, at either time-point. In a further analysis, a moderate to strong correlation was observed in the linear relationship between the CI and the MPG (r = 0.60; p < 0.001). During the in-hospital follow-up period, no patients died or required an intervention due to LAVV stenosis. Conclusions: The Doppler-based quantification of diastolic transvalvular LAVV mean pressure gradients using intraoperative transesophageal echocardiography seems to be prone to overestimation due to altered hemodynamics immediately after an AVSD repair. Thus, the current hemodynamic state should be taken into consideration during the intraoperative interpretation of these gradients.

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2021

Year:

2021

Year:

2021

Year:

2021

Collaborators (5)

Harry Magunia

University Hospital Tübingen

GERMANY
View details

Michael Koeppen

University Hospital Tübingen

GERMANY
View details

Mario Lescan

-

GERMANY
View details

Valbona Mirakaj

Head of Division of Molecular Intensive Care Medicine

Eberhard Karls Universität Tübingen

GERMANY
View details

Michael Hofbeck

Head of Department

-

GERMANY
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.