Matthan W.A. Caan

Assistant Professor

Amsterdam UMC
Country flagNetherlands

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

About

Matthan W.A. Caan is an Assistant Professor at Amsterdam UMC, Netherlands. His research primarily focuses on advanced magnetic resonance imaging (MRI) techniques, including compressed sensing and ultra-high resolution imaging methods. Recent articles highlight his work on predicting treatment responses in major depressive disorder and developing tools for artificial intelligence applications in medical imaging.

Articles (17)

Year:

2025

Year:

2025

Year:

2025

Year:

2024

Year:

2024

Year:

2024

Purpose To obtain homogeneous signal throughout the human liver at 7 T. Flip angle (FA) shimming in 7T whole‐liver imaging was performed through parallel‐transmit k T ‐point pulses based on subject‐specific multichannel absolute maps from Fourier phase‐encoded dual refocusing echo acquisition mode (PE‐DREAM). Methods The optimal number of Fourier phase‐encoding steps for PE‐DREAM mapping was determined for a 7T eight‐channel parallel‐transmission system. FA shimming experiments were performed in the liver of 7 healthy subjects with varying body mass index. In these subjects, first shimming and Fourier PE‐DREAM mapping were performed. Subsequently, three small‐flip‐angle 3D gradient‐echo scans were acquired, comparing a circularly polarized (CP) mode, a phase shim, and a k T ‐point pulse. Resulting homogeneity was assessed and compared with estimated FA maps and distributions. Results Fourier PE‐DREAM with 13 phase‐encoding steps resulted in a good tradeoff between accuracy and scan time. Lower coefficient of variation values (average [min‐max] across subjects) of the estimated FA in the volume of interest were observed using k T ‐points (7.4 [6.6%–8.0%]), compared with phase shimming (18.8 [12.9%–23.4%], p < 0.001) and CP (43.2 [39.4%–47.1%], p < 0.001). k T ‐points delivered whole‐liver images with the nominal FA and the highest degree of homogeneity. CP and phase shimming resulted in either inaccurate or imprecise FA distributions. Here, locations having suboptimal FA in the estimated FA maps corresponded to liver areas suffering from inconsistent signal intensity and T 1 ‐weighting in the gradient‐echo scans. Conclusion Homogeneous whole‐liver 3D gradient‐echo acquisitions at 7 T can be obtained with eight‐channel k T ‐point pulses calculated based on subject‐specific multichannel absolute Fourier PE‐DREAM maps.

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Year:

2021

Year:

2020

Year:

2020

Year:

2020

Year:

2020

Year:

2020

Year:

2020

Collaborators (6)

Aart J. Nederveen

-

NETHERLANDS
View details

mario maas

Professor of Radiology

Amsterdam University Medical Centers

NETHERLANDS
View details

serge bracard

Université de Lorraine

FRANCE
View details

Michael Noseworthy

Professor

McMaster University Faculty of Engineering

CANADA
View details

francis guillemin

Université de Lorraine

FRANCE
View details

Bonnie Klimes-Dougan

University of Minnesota

UNITED STATES
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.