Matthan W.A. Caan
Assistant Professor
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Matthan W.A. Caan is an Assistant Professor at Amsterdam UMC, Netherlands. His research primarily focuses on advanced magnetic resonance imaging (MRI) techniques, including compressed sensing and ultra-high resolution imaging methods. Recent articles highlight his work on predicting treatment responses in major depressive disorder and developing tools for artificial intelligence applications in medical imaging.
Articles (17)
Year:
2025
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Purpose To obtain homogeneous signal throughout the human liver at 7 T. Flip angle (FA) shimming in 7T whole‐liver imaging was performed through parallel‐transmit k T ‐point pulses based on subject‐specific multichannel absolute maps from Fourier phase‐encoded dual refocusing echo acquisition mode (PE‐DREAM). Methods The optimal number of Fourier phase‐encoding steps for PE‐DREAM mapping was determined for a 7T eight‐channel parallel‐transmission system. FA shimming experiments were performed in the liver of 7 healthy subjects with varying body mass index. In these subjects, first shimming and Fourier PE‐DREAM mapping were performed. Subsequently, three small‐flip‐angle 3D gradient‐echo scans were acquired, comparing a circularly polarized (CP) mode, a phase shim, and a k T ‐point pulse. Resulting homogeneity was assessed and compared with estimated FA maps and distributions. Results Fourier PE‐DREAM with 13 phase‐encoding steps resulted in a good tradeoff between accuracy and scan time. Lower coefficient of variation values (average [min‐max] across subjects) of the estimated FA in the volume of interest were observed using k T ‐points (7.4 [6.6%–8.0%]), compared with phase shimming (18.8 [12.9%–23.4%], p < 0.001) and CP (43.2 [39.4%–47.1%], p < 0.001). k T ‐points delivered whole‐liver images with the nominal FA and the highest degree of homogeneity. CP and phase shimming resulted in either inaccurate or imprecise FA distributions. Here, locations having suboptimal FA in the estimated FA maps corresponded to liver areas suffering from inconsistent signal intensity and T 1 ‐weighting in the gradient‐echo scans. Conclusion Homogeneous whole‐liver 3D gradient‐echo acquisitions at 7 T can be obtained with eight‐channel k T ‐point pulses calculated based on subject‐specific multichannel absolute Fourier PE‐DREAM maps.
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2020
Year:
2020
Year:
2020
Year:
2020
Year:
2020
Year:
2020
Collaborators (6)
Aart J. Nederveen
-
mario maas
Professor of Radiology
Amsterdam University Medical Centers
serge bracard
Université de Lorraine
Michael Noseworthy
Professor
McMaster University Faculty of Engineering
francis guillemin
Université de Lorraine
Bonnie Klimes-Dougan
University of Minnesota
Make your next move.
Prepare your application
Review drafts before you send them.