Matthias A. Fink

University Hospital Heidelberg
Country flag
Germany

Research Interests

Explore related searches

Contact this professor

LinkedIn
ORCID
Google Scholar

Articles (11)

BMI-Adapted Double Low-Dose Dual-Source Aortic CT for Endoleak Detection after Endovascular Repair: A Prospective Intra-Individual Diagnostic Accuracy Study

Purpose: To assess the diagnostic accuracy of BMI-adapted, low-radiation and low-iodine dose, dual-source aortic CT for endoleak detection in non-obese and obese patients following endovascular aortic repair. Methods: In this prospective single-center study, patients referred for follow-up CT after endovascular repair with a history of at least one standard triphasic (native, arterial and delayed phase) routine CT protocol were enrolled. Patients were divided into two groups and allocated to a BMI-adapted (group A, BMI < 30 kg/m2; group B, BMI ≥ 30 kg/m2) double low-dose CT (DLCT) protocol comprising single-energy arterial and dual-energy delayed phase series with virtual non-contrast (VNC) reconstructions. An in-patient comparison of the DLCT and routine CT protocol as reference standard was performed regarding differences in diagnostic accuracy, radiation dose, and image quality. Results: Seventy-five patients were included in the study (mean age 73 ± 8 years, 63 (84%) male). Endoleaks were diagnosed in 20 (26.7%) patients, 11 of 53 (20.8%) in group A and 9 of 22 (40.9%) in group B. Two radiologists achieved an overall diagnostic accuracy of 98.7% and 97.3% for endoleak detection, with 100% in group A and 95.5% and 90.9% in group B. All examinations were diagnostic. The DLCT protocol reduced the effective dose from 10.0 ± 3.6 mSv to 6.1 ± 1.5 mSv (p < 0.001) and the total iodine dose from 31.5 g to 14.5 g in group A and to 17.4 g in group B. Conclusion: Optimized double low-dose dual-source aortic CT with VNC, arterial and delayed phase images demonstrated high diagnostic accuracy for endoleak detection and significant radiation and iodine dose reductions in both obese and non-obese patients compared to the reference standard of triple phase, standard radiation and iodine dose aortic CT.

Year:

2024

Collaborators (5)

Andreas M. Bucher

University Hospital

GERMANY

Hans-Ulrich Kauczor

Heidelberg University

GERMANY

Thuy D. Do

University Hospital Heidelberg

GERMANY

Constantin Seibold

Karlsruher Institut für Technologie

GERMANY

Pascal Probst

Heidelberg University

GERMANY
Social connections

How do I reach out?

Sign in for free to see their profile details and contact information.

Meet Kite AI