Thuy D. Do

University Hospital Heidelberg
Country flagGermany

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (10)

Purpose: To assess the diagnostic accuracy of BMI-adapted, low-radiation and low-iodine dose, dual-source aortic CT for endoleak detection in non-obese and obese patients following endovascular aortic repair. Methods: In this prospective single-center study, patients referred for follow-up CT after endovascular repair with a history of at least one standard triphasic (native, arterial and delayed phase) routine CT protocol were enrolled. Patients were divided into two groups and allocated to a BMI-adapted (group A, BMI < 30 kg/m2; group B, BMI ≥ 30 kg/m2) double low-dose CT (DLCT) protocol comprising single-energy arterial and dual-energy delayed phase series with virtual non-contrast (VNC) reconstructions. An in-patient comparison of the DLCT and routine CT protocol as reference standard was performed regarding differences in diagnostic accuracy, radiation dose, and image quality. Results: Seventy-five patients were included in the study (mean age 73 ± 8 years, 63 (84%) male). Endoleaks were diagnosed in 20 (26.7%) patients, 11 of 53 (20.8%) in group A and 9 of 22 (40.9%) in group B. Two radiologists achieved an overall diagnostic accuracy of 98.7% and 97.3% for endoleak detection, with 100% in group A and 95.5% and 90.9% in group B. All examinations were diagnostic. The DLCT protocol reduced the effective dose from 10.0 ± 3.6 mSv to 6.1 ± 1.5 mSv (p < 0.001) and the total iodine dose from 31.5 g to 14.5 g in group A and to 17.4 g in group B. Conclusion: Optimized double low-dose dual-source aortic CT with VNC, arterial and delayed phase images demonstrated high diagnostic accuracy for endoleak detection and significant radiation and iodine dose reductions in both obese and non-obese patients compared to the reference standard of triple phase, standard radiation and iodine dose aortic CT.

Year:

2024

Reduced iodine loads for computed tomography (CT)-based vascular assessment prior to transcatheter aortic valve implantation (TAVI) may be feasible in conjunction with a spectral detector CT scanner. This prospective single-center study considered 100 consecutive patients clinically referred for pre-TAVI CT. They were examined on a dual-layer detector CT scanner to obtain an ECG-gated cardiac scan and a non-ECG-gated aortoiliofemoral scan. Either a standard contrast media (SCM) protocol using 80 mL Iohexol 350 mgI/mL (iodine load: 28 gI) or a body-mass-index adjusted reduced contrast media (RCM) protocol using 40–70 mL Iohexol 350 mgI/mL (iodine load: 14–24.5 gI) were employed. Conventional images and virtual monoenergetic images at 40–80 keV were reconstructed. A threshold of 250 HU was set for sufficient attenuation along the arterial access pathway. A qualitative assessment used a five-point Likert scale. Sufficient attenuation in the thoracic aorta was observed for all patients in both groups using conventional images. In the abdominal, iliac, and femoral segments, sufficient attenuation was observed for the majority of patients when using virtual monoenergetic images (SCM: 96–100% of patients, RCM: 88–94%) without statistical difference between both groups. Segments with attenuation measurements below the threshold remained qualitatively assessable as well. Likert scores were ‘excellent’ for virtual monoenergetic images 50 keV and 55 keV in both groups (RCM: 1.2–1.4, SCM: 1.2–1.3). With diagnostic image quality maintained, it can be concluded that reduced iodine loads of 14–24.5 gI are feasible for pre-TAVI vascular assessment on a spectral detector CT scanner.

Year:

2024

Year:

2024

Year:

2024

Year:

2022

Purpose Report of experience from a single institution in treating postoperative lymphatic leakage (PLL) applying conventional transpedal lymphangiography (TL). Materials and Methods 453 patients with the initial diagnosis of PLL receiving TL between 03/1993 and 09/2018 were identified in the database. Only patients with confirmed PLL were included in the study. The technical success, safety, and treatment success of TL were evaluated. Independent predictors of TL treatment failure were examined using univariate and multivariate logistic regression analysis. Results 355 consecutive patients (218 men, 137 women; median age of 62 years) who underwent TL for PLL (e. g., chylothorax) after ineffective conservative treatment were included. The median time between causal surgery and TL was 27 days. The median technical success rate of TL was 88.5 %, with a median volume of Lipiodol of 10.0 ml. No complication of TL was recorded. Three groups were defined according to the different clinical courses: group A (41/355, 11.5 %) – TL with technical failure; group B (258/355, 72.7 %) – “therapeutic” TL alone with technical success; and group C (56/355, 15.8 %) – “diagnostic” TL with simultaneously invasive treatment (incl. surgical revision and percutaneous sclerotherapy). Treatment success rate and median time to treatment success were higher in group C than in group B, but without significant differences (64.3 % vs. 61.6 %, p = 0.710; six vs. five days, p = 0.065). Univariate and multivariate logistic regression analyses for group B confirmed drainage volume (> 500 ml/d) and Lipiodol extravasation as independent predictors of TL clinical failure (odds ratios [ORs] of 2.128 and 2.372 [p = 0.005 and p = 0.003, respectively]). Conclusion TL is technically reliable, safe, and effective in treating PLL. When conservative treatment fails, TL can be regarded as the next treatment option. Key Points: Citation Format

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Collaborators (3)

Matthias A. Fink

University Hospital Heidelberg

GERMANY
View details

Maximilian Kittel

Ruprecht-Karls-Universität Heidelberg Medizinische Fakultät Mannheim

GERMANY
View details

Christof M. Sommer

University Hospital Heidelberg

GERMANY
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.