Nico Verdonschot

Has grant

University of Twente
Country flagNetherlands

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Recent Grants

Grant: Close

Improving bone-preserving effect following total hip arthroplasty by using a femoral stem made of Ti-33.6Nb-4Sn with a Young's modulus gradation(Fostering Joint International Research)

Open Date: 2016-04-25

Close Date: 2017-12-31

Grant: Close

A novel biomechanically based fracture scoring method to improve clinical decision making in patients with cancer and femoral bone metastases

Open Date: 2013-09-01

Close Date: 2017-09-01

Grant: Close

Biomechanical diagnostic, pre-planning and outcome tools to improve musculoskeletal surgery

Open Date: 2013-05-01

Close Date: 2018-04-30

Grant: Close

Improving safety and predictability of complex musculo-skeletal surgery using a patient-specific navigation system

Open Date: 2010-03-01

Close Date: 2014-08-31

Grant: Close

External activation of resorbable materials

Open Date: 2005-09-23

Close Date: 2006-05-31

Articles (11)

This paper introduces a method for measuring 3D tibiofemoral kinematics using a multi-channel A-mode ultrasound system under dynamic conditions. The proposed system consists of a multi-channel A-mode ultrasound system integrated with a conventional motion capture system (i.e., optical tracking system). This approach allows for the non-invasive and non-radiative quantification of the tibiofemoral joint’s six degrees of freedom (DOF). We demonstrated the feasibility and accuracy of this method in the cadaveric experiment. The knee joint’s motions were mimicked by manually manipulating the leg through multiple motion cycles from flexion to extension. To measure it, six custom ultrasound holders, equipped with a total of 30 A-mode ultrasound transducers and 18 optical markers, were mounted on various anatomical regions of the lower extremity of the specimen. During experiments, 3D-tracked intra-cortical bone pins were inserted into the femur and tibia to measure the ground truth of tibiofemoral kinematics. The results were compared with the tibiofemoral kinematics derived from the proposed ultrasound system. The results showed an average rotational error of 1.51 ± 1.13° and a translational error of 3.14 ± 1.72 mm for the ultrasound-derived kinematics, compared to the ground truth. In conclusion, this multi-channel A-mode ultrasound system demonstrated a great potential of effectively measuring tibiofemoral kinematics during dynamic motions. Its improved accuracy, nature of non-invasiveness, and lack of radiation exposure make this method a promising alternative to incorporate into gait analysis and prosthetic kinematic measurements later.

Year:

2024

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Collaborators (2)

Jasper Homminga

University of Twente

NETHERLANDS
View details

Bangyu Lan

University of Twente

NETHERLANDS
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.