Patricia Capsi Morales

Professor of Human-Centered Robotics

University of Technology Nuremberg
Country flagGermany

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (13)

Year:

2026

Year:

2026

Year:

2026

Despite the advances in bionic reconstruction of missing limbs, the control of robotic limbs is still limited and, in most cases, not felt to be as natural by users. In this study, we introduce a control approach that combines robotic design based on postural synergies and neural decoding of synergistic behavior of spinal motoneurons. We developed a soft prosthetic hand with two degrees of actuation that realizes postures in a two-dimensional linear manifold generated by two postural synergies. Through a manipulation task in nine participants without physical impairment, we investigated how to map neural commands to the postural synergies. We found that neural synergies outperformed classic muscle synergies in terms of dimensionality and robustness. Leveraging these findings, we developed an online method to map the decoded neural synergies into continuous control of the two-synergy prosthetic hand, which was tested on 11 participants without physical impairment and three prosthesis users in real-time scenarios. Results demonstrated that combined neural and postural synergies allowed accurate and natural control of coordinated multidigit actions (>90% of the continuous mechanical manifold could be reached). The target hit rate for specific hand postures was higher with neural synergies compared with muscle synergies, with the difference being particularly pronounced for prosthesis users (prosthesis users, 82.5% versus 35.0%; other participants, 79.5% versus 54.5%). This demonstration of codesign of multisynergistic robotic hands and neural decoding algorithms enabled users to achieve natural modular control to span infinite postures across a two-dimensional space and to execute dexterous tasks, including in-hand manipulation, not feasible with other approaches.

Year:

2025

The human hand is an intricate anatomical structure essential for daily activities, yet replicating its full functionality in upper-limb prostheses remains a significant challenge. Despite advances in mechanical design leading to more sophisticated and dexterous artificial hands, difficulties persist in effectively controlling these prostheses due to the limitations posed by the muscle conditions of their users. These constraints result in a limited number of control inputs and a lack of sensory feedback. To address these issues, various semi-autonomous control strategies have been proposed, which integrate sensing technologies to complement traditional myoelectric control. Inspired by human grasping physiology, we propose a shared control strategy that divides grasp control into two levels: a high-level controller, operated by the user to initiate the grasp action, and a low-level controller, which ensures stability throughout the task. This work focuses specifically on slip detection methods, introducing improvements to the low-level controller to enable more autonomous grasping behavior during object holding. The proposed slip module uses distributed 3D force sensors across the artificial hand and integrates a friction cone strategy to ensure an appropriate shear-to-normal force ratio with bandpass filtering for establishing an initial stable grasp model without prior knowledge. Experimental evaluations consist of the comparison of this novel controller with conventional state-of-the-art approaches. Results demonstrate its efficacy in preventing slippage while requiring less grasping force than previous methods. Additionally, a qualitative validation was conducted to assess its responsiveness compared to human grasping reactions to unexpected weight changes, yielding positive outcomes.

Year:

2025

Advanced myoelectric prostheses feature multiple degrees of freedom (DoFs) and sophisticated control algorithms that interpret user motor intentions as commands. While enhancing their capability to assist users in a wide range of daily activities, these control solutions still pose challenges. Among them, the need for extensive learning periods and users’ limited control proficiency. To investigate the relationship between these challenges and the limited alignment of such methods with human motor control strategies, we examine motor learning processes in two different control maps testing a synergistic myoelectric system. In particular, this work employs a DoF-wise synergies control algorithm tested in both intuitive and non-intuitive control mappings. Intuitive mapping aligns body movements with control actions to replicate natural limb control, whereas non-intuitive mapping (or non-biomimetic) lacks a direct correlation between aspects, allowing one body movement to influence multiple DoFs. The latter offers increased design flexibility through redundancy, which can be especially advantageous for individuals with motor disabilities. The study evaluates the effectiveness and learning process of both control mappings with 10 able-bodied participants. The results revealed distinct patterns observed while testing the two maps. Furthermore, muscle synergies exhibited greater stability and distinction by the end of the experiment, indicative of varied learning processes.

Year:

2025

Introduction Despite recent technological advances that have led to sophisticated bionic prostheses, attaining embodied solutions still remains a challenge. Recently, the investigation of prosthetic embodiment has become a topic of interest in the research community, which deals with enhancing the perception of artificial limbs as part of users’ own body. Surface electromyography (sEMG) interfaces have emerged as a promising technology for enhancing upper-limb prosthetic control. However, little is known about the impact of these sEMG interfaces on users’ experience regarding embodiment and their interaction with different functional levels. Methods To investigate this aspect, a comparison is conducted among sEMG configurations with different number of sensors (4 and 16 channels) and different time delay. We used a regression algorithm to simultaneously control hand closing/opening and forearm pronation/supination in an immersive virtual reality environment. The experimental evaluation includes 24 able-bodied subjects and one prosthesis user. We assess functionality with the Target Achievement Control test, and the sense of embodiment with a metric for the users perception of self-location, together with a standard survey. Results Among the four tested conditions, results proved a higher subjective embodiment when participants used sEMG interfaces employing an increased number of sensors. Regarding functionality, significant improvement over time is observed in the same conditions, independently of the time delay implemented. Conclusions Our work indicates that a sufficient number of sEMG sensors improves both, functional and subjective embodiment outcomes. This prompts discussion regarding the potential relationship between these two aspects present in bionic integration. Similar embodiment outcomes are observed in the prosthesis user, showing also differences due to the time delay, and demonstrating the influence of sEMG interfaces on the sense of agency.

Year:

2024

Wrist mobility contributes significantly to the execution of upper limb motor tasks. Despite this, current prosthetic wrists are far less advanced than other artificial joints. Typically, prosthetic wrists offer limited degrees of freedom, if any, which forces users to execute compensatory movements during task performance. This addition increases weight and complexity, two unwelcome factors in upper limb prostheses. This article presents the design of a 3-degree-of-freedom friction-lockable prosthetic wrist actuated by a single motor. The design features adaptable behavior when unlocked, promoting a gentle interaction with the environment, and enables users to adjust the hand configuration during pre-grasping phases. The proposed system was tested, combined with a hand prosthesis, and compared to a commercial rotational wrist during the execution of functional movements. Experiments involved nine able-bodied subjects and one prosthesis user. Participants also performed the experiments with their biological wrist (the intact wrist for the prosthesis user) as a control. Results showed that the lockable wrist was used actively 20% more often than the commercial solution without compromising users’ execution time. Interaction tests reveal that compensatory movements are reduced when using the proposed design, resulting in closer resemblance to the control wrist’s performance. The average satisfaction and usability scores were significantly higher for the proposed wrist, indicating its potential acceptance. Finally, the system was validated in a set of activities of daily living performed by the prosthesis user. The study contributes to the development of more intuitive and adaptable prostheses that can improve the quality of life of amputees.

Year:

2024

Year:

2024

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Collaborators (10)

Kristen Kozielski

Technical University of Munich

GERMANY
View details

Cristina Piazza

Tenure Track Assistant Professor

Technical University of Munich

GERMANY
View details

Jakob Dideriksen

Aalborg University

DENMARK
View details

Strahinja Dosen

Aalborg University

DENMARK
View details

Sandro M. Krieg

Chair

University Hospital Heidelberg

GERMANY
View details

Arthur Wagner

Technical University of Munich

GERMANY
View details

Joachim Hermsdörfer

Professor - Chair of Human Movement Science

Technical University of Munich

GERMANY
View details

Claudio Castellini

Full professor in medical robotics

University of Erlangen-Nuremberg

GERMANY
View details

Yong Kuk Kim

ETH Zurich

SWITZERLAND
View details

Liselotte Hermansson

Affiliated Professor

Örebro University Hospital

SWEDEN
View details