Pierre-Jean Cottinet

Full Professor

Institut National des Sciences Appliquées de Lyon
Country flagFrance

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (20)

Year:

2026

Year:

2026

Flexible force sensor arrays have gained significant interest in recent years for healthcare applications, particularly with the rising prevalence of wearable devices. However, several challenges must be overcome before their widespread adoption. This study presents a flexible piezoelectric array tailored for low frequency applications, such as tactile sensing and cardiovascular monitoring. The proposed array is fabricated using a fast and cost‐effective screen‐printing process integrating flexible electromagnetic interference (EMI) shielding. Its structure is intentionally designed to accurately measure forces across complex surfaces, with miniaturized interface electronics capable of processing up to 128 piezoelectric signals simultaneously. By dividing the device into two distinct sections, the design of the EMI shielding strikes a balance between flexibility and effectiveness. The impact on the electromechanical performance is minimal, with a slight decrease in sensitivity of only 25%, while the benefits to signal quality are significant. Notably, measurement noise is eliminated up to 10 kHz, well above the relevant frequency ranges for the targeted applications. Other electromechanical couplings such as triboelectricity and flexoelectricity are also effectively mitigated. The limitations of this study are discussed, and a novel sensor structure is proposed as a perspective, offering exceptional performance with a sensitivity in compression of 700 pC N −1 .

Year:

2026

Mitral valve repair (MVr) is the preferred surgical treatment for primary mitral regurgitation; however, its success is limited by the lack of validated, accurate, and objective parameters for assessing the complete restoration of physiological mitral valve (MV) mechanics. Consequently, to address this challenge, intraoperative assessment of mitral valve coaptation pressure (MCP) has emerged as a promising approach. This study presents the first precise transcatheter measurement of MCP in animal hearts. Data were obtained using two custom‐made force sensors: a 3Fr piezoresistive pressure catheter and a 15Fr flexible piezoelectric sensor. Experiments were conducted in both ex vivo (excised pig hearts activated by a pump) and in vivo (transseptal approach in a living pig) models. In a living pig with a healthy MV under normal hemodynamic conditions (peak systolic left ventricular pressure of 100 mmHg), the MCP ranged from 200 to 300 mmHg (25–40 kPa). Ex vivo experiments demonstrated that MCP was affected by transmitral pressure, mitral function changes (i.e., regurgitation), and MV morphology. These findings provide valuable insights into MV biomechanics and establish a solid foundation for developing medical devices to guide MVr procedures.

Year:

2026

This study offers a detailed exploration of the dielectrophoretic structuring of filler size hybrid thermally conductive composites, emphasizing the impact of filler size hybridization on the thermal and mechanical properties of PDMS‐Al 2 O 3 composites. By comparing the performance of monodisperse and hybrid composites, we highlight the advantages of size hybridization in optimizing composite properties. The results indicate significant improvements in thermal conductivity and mechanical stiffness due to enhanced filler packing density and more efficient structuring. Our investigation into various compositions and size ratios reveals optimal thermal properties at specific hybridization levels, suggesting key parameters for superior composite performance. These results demonstrate the advantage of combining size hybridization with dielectrophoretic structuring to design advanced composites for thermal management, while emphasizing the need for future studies to tackle environmental concerns and investigate alternative polymer matrices.

Year:

2025

Year:

2025

This work presents a comprehensive study on the synthesis and application of Al2O3 fibers derived from an ammonium aluminum carbonate hydroxide (AACH) precursor. Through a hydrothermal route, the influence of critical synthesis parameters, including aluminum nitrate and urea concentrations, reaction temperature and time, and stirring conditions, on fiber morphology and aspect ratio was systematically investigated. The as-synthesized AACH fibers were subsequently converted into thermodynamically stable α-alumina fibers via controlled annealing. These high-aspect ratio alumina fibers were incorporated into polydimethylsiloxane (PDMS) to produce electrically insulating, thermally conductive composites. The thermal performance of fiber-filled composites was benchmarked against that of particle-filled counterparts, with the former exhibiting significantly enhanced thermal conductivity. Furthermore, the dielectrophoretic alignment of alumina fibers led to an additional increase in thermal conductivity, underlining the importance of high-aspect ratio fillers. This study uniquely combines the controlled synthesis of alumina fibers with their incorporation and alignment in a polymer matrix, presenting a novel and effective approach for engineering anisotropic, thermally conductive, and electrically insulating composite materials. Dielectrophoretic alignment of α-Al2O3 fibers synthesized through optimized hydrothermal conditions and incorporated into PDMS composites deliver over 95 % higher thermal conductivity than spherical fillers.

Year:

2025

This work presents a comparative study on the ageing of supercapacitors and a method for monitoring their state of health (SoH) through mechanical deformation. This study aims to evaluate the accelerated ageing behaviours of these systems under specific cycling conditions and temperatures, allowing the establishment of a correlation between SoH and casing deformation in supercapacitors. Experimental ageing tests revealed supercapacitors displayed an initial “burning” phase followed by a linear ageing trend. Strain gauges were employed to measure the mechanical deformation of supercapacitor casings, providing real-time insights into their SoH. Capacitance fading in supercapacitors was modelled using Brunauer–Emmett–Teller (BET) theory, hypothesizing that gas adsorption during ageing significantly contributes to performance decline. Model predictions were validated against experimental data, demonstrating a clear correlation between capacitance fading, internal resistance, remaining energy, and casing deformation. This work highlights the potential of mechanical deformation monitoring as a practical and non-invasive approach for assessing the SoH of supercapacitors.

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Collaborators (7)

Jean-Fabien Capsal

Associate Professor

Institut National des Sciences Appliquées de Lyon

FRANCE
View details

Minh-Quyen Le

Associate Professor

Institut National des Sciences Appliquées de Lyon

FRANCE
View details

Pascal Venet

Full Professor

Université Claude Bernard Lyon 1

FRANCE
View details

Kerem Ege

Assistant Professor ( HDR)

-

FRANCE
View details

Guilhem Rival

Assistant Professor

-

FRANCE
View details

Christine Revenant

Commissariat à l’énergie atomique et aux énergies alternatives Direction CEA Tech

FRANCE
View details

Alaa Hijazi

associate professor

Institut National des Sciences Appliquées de Lyon

FRANCE
View details