Sina Straub
Has grant
Research Scientist
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Recent Grants
Grant: Close
MR image reconstruction for non-Cartesian data and quantitative susceptibility maps using generalized sampling
Open Date: 2017-01-01
Close Date:
Articles (11)
Year:
2026
Year:
2026
Quantitative susceptibility mapping (QSM) is a tool for mapping tissue susceptibility. Using QSM for functional brain mapping, it is possible to directly quantify blood‐oxygen‐level‐dependent (BOLD) susceptibility changes. This study presents a submillimeter functional QSM (fQSM) approach compared to BOLD fMRI from data acquired with 3D gradient‐echo echo planar imaging (EPI) at ultra‐high field. Complex EPI data were acquired in nine healthy subjects with varying temporal and spatial resolutions and used for BOLD fMRI and for fQSM. Right‐hand finger tapping experiments were performed as well as one measurement with intentional subject movement. Susceptibility maps were computed using 3D path‐based unwrapping, the variable‐kernel sophisticated harmonic artifact reduction for phase data, and the streaking artifact reduction for QSM algorithm. Functional data analysis included general linear modeling and computation of z ‐scores. Submillimeter data were denoised using NOise reduction with DIstribution Corrected (NORDIC), which improved z ‐scores in the motor cortex for fQSM and fMRI. An expected increase in BOLD fMRI signal and corresponding decrease in magnetic susceptibility was observed in sensorimotor areas during active periods. For all experiments, fQSM showed smaller activation regions compared with fMRI. The percentage of high negative t ‐values localized in the cortex was higher for fQSM (52%) than for positive or negative t ‐values for fMRI (45%). For the scans with intentional motion, movement exceeded the size of a voxel, but paradigm dependent signal evolution could be recovered using motion correction. In conclusion, this study demonstrates the feasibility of submillimeter whole‐brain fQSM with voxel volume of 0.53 μL. In comparison to traditional BOLD fMRI, fQSM provided improved localization of brain activation within the cortex, especially in submillimeter 3D EPI sequences.
Year:
2025
Purpose Accurate electrode placement is essential for studies using transcranial direct current stimulation (tDCS) since it determines whether – and to which extent - the intended brain region was modulated. Precise electrode placement also reduces between-subject variability. Using in-scanner tDCS, accuracy and precision of electrode placement can be determined. Previous studies manually segmented electrode positions from structural MRI, a process that is time-consuming and prone to error. We therefore developed an algorithm that automatedly extracts electrode coordinates from structural MRI. Methods We applied this algorithm to 49 datasets acquired at diferent field strengths (3 T and 7 T), with two image resolutions and electrode montages (bifrontal or ring-shaped) targeting the dorsolateral prefrontal cortex. We validated its accuracy by comparing the automatedly extracted coordinates with manual annotations from two independent readers. We then used the actual and intended electrode coordinates to simulate how electrode placement deviations influenced the resulting electric field. Results For all setups and scanners, the median localization error of the algorithm was 2.3 mm. It was within 1 mm of the variability between human readers (2.7 mm), indicating human-level reliability. Large deviations (> 20 mm) from intended positions led to substantial changes in the electric field - up to 35% for the ring-shaped montage -highlighting the need for placement verification in tDCS studies. Conclusion The proposed algorithm obviates the need for manual electrode segmentation and allows an objective evaluation of electrode placement accuracy and precision for in-scanner tDCS. It may be used to relate electrode position errors to stimulation efects, thereby supporting reproducible tDCS research.
Year:
2025
This article provides recommendations for implementing QSM for clinical brain research. It is a consensus of the International Society of Magnetic Resonance in Medicine, Electro‐Magnetic Tissue Properties Study Group. While QSM technical development continues to advance rapidly, the current QSM methods have been demonstrated to be repeatable and reproducible for generating quantitative tissue magnetic susceptibility maps in the brain. However, the many QSM approaches available have generated a need in the neuroimaging community for guidelines on implementation. This article outlines considerations and implementation recommendations for QSM data acquisition, processing, analysis, and publication. We recommend that data be acquired using a monopolar 3D multi‐echo gradient echo (GRE) sequence and that phase images be saved and exported in Digital Imaging and Communications in Medicine (DICOM) format and unwrapped using an exact unwrapping approach. Multi‐echo images should be combined before background field removal, and a brain mask created using a brain extraction tool with the incorporation of phase‐quality‐based masking. Background fields within the brain mask should be removed using a technique based on SHARP or PDF, and the optimization approach to dipole inversion should be employed with a sparsity‐based regularization. Susceptibility values should be measured relative to a specified reference, including the common reference region of the whole brain as a region of interest in the analysis. The minimum acquisition and processing details required when reporting QSM results are also provided. These recommendations should facilitate clinical QSM research and promote harmonized data acquisition, analysis, and reporting.
Year:
2024
Parkinson’s disease (PD) is a prevalent neurodegenerative disorder that presents a diagnostic challenge due to symptom overlap with other disorders. Neuromelanin (NM) imaging is a promising biomarker for PD, but adoption has been limited, in part due to subpar performance at standard MRI field strengths. We aimed to evaluate the diagnostic utility of ultra-high field 7T NM-sensitive imaging in the diagnosis of PD versus controls and essential tremor (ET), as well as NM differences among PD subtypes. A retrospective case-control study was conducted including PD patients, ET patients, and controls. 7T NM-sensitive 3D-GRE was acquired, and substantia nigra pars compacta (SNpc) volumes, contrast ratios, and asymmetry indices were calculated. Statistical analyses, including general linear models and ROC curves, were employed. Twenty-one PD patients, 13 ET patients, and 18 controls were assessed. PD patients exhibited significantly lower SNpc volumes compared to non-PD subjects. SNpc total volume showed 100% sensitivity and 96.8% specificity (AUC = 0.998) for differentiating PD from non-PD and 100% sensitivity and 95.2% specificity (AUC = 0.996) in differentiating PD from ET. Contrast ratio was not significantly different between PD and non-PD groups ( p = 0.07). There was also significantly higher asymmetry index in SNpc volume in PD compared to non-PD cohorts ( p < 0.001). NM signal loss in PD predominantly involved the inferior, posterior, and lateral aspects of SNpc. Akinetic-rigid subtype showed more significant NM signal loss compared to tremor dominant subtype ( p < 0.001). 7T NM imaging demonstrates potential as a diagnostic tool for PD, including potential distinction between subtypes, allowing improved understanding of disease progression and subtype-related characteristics.
Year:
2024
OBJECTIVE The aim of this study was to compare outcomes of direct targeting in deep brain stimulation (DBS) for essential tremor using 7T MRI versus 3T MRI. The authors hypothesized that 7T MRI direct targeting would be noninferior to 3T MRI in early tremor outcomes. METHODS A retrospective study was conducted on patients undergoing unilateral thalamic DBS for essential tremor between 2021 and 2023. Two matched cohorts were assessed, one using 7T MRI and the other using 3T MRI for surgical planning. The primary endpoint was the percentage improvement in the Fahn-Tolosa-Marin Tremor Rating Scale (TRS) scores. Additionally, the authors assessed optimized programming settings and variance in electrode position on postoperative imaging. Demographic and clinical data were compared using the nonparametric Mann-Whitney U-test. The squared Euclidean distance of each contact from the group mean centroid was calculated and averaged across the entire cohort to provide the variance (i.e., the mean squared distance) of electrode contact position. RESULTS A total of 34 patients were analyzed, with 17 in each cohort. There were no significant differences in demographic information or mean surgical dates between the groups. There were no differences in intraoperative target repositioning or adverse events. The 7T group had a significantly greater TRS improvement than the 3T group (64.9% ± 11.4% vs 50.9% ± 16.4%, p = 0.004). Patients in the 7T cohort also had a lower mean stimulation current compared with those in the 3T cohort (2.0 ± 0.8 mA vs 2.7 ± 0.9 mA, p = 0.01). Image evaluation revealed that although the mean electrode position was comparable between 7T and 3T, the 7T electrode positioning was more clustered, indicating a lower variance in the final electrode location. The mean Euclidean distance between the individual electrode tips and the group centroid was significantly less at 7T than at 3T (1.82 ± 0.68 mm vs 2.75 ± 0.81 mm, p = 0.001). CONCLUSIONS Despite concerns for increased artifacts and distortions at 7T, the authors show that these effects can be mitigated with an appropriate workflow, leading to improved surgical outcomes with direct targeting using 7T MRI. Their results suggest similar accuracy but greater precision in targeting with 7T MRI compared with 3T MRI, resulting in lower stimulation currents and improved tremor reduction. Future studies are needed to assess outcomes related to 7T MRI in targeting other subcortical structures.
Year:
2024
Objectives Detection of infratentorial demyelinating lesions in multiple sclerosis (MS) presents a challenge in magnetic resonance imaging (MRI), a difficulty that is further heightened in 7 T MRI. This study aimed to assess the efficacy of a novel MRI approach, lesion-attenuated magnetization-prepared gradient echo acquisition (LAMA), for detecting demyelinating lesions within the posterior fossa and upper cervical spine on 7 T MRI and contrast its performance with conventional double-inversion recovery (DIR) and T2-weighted turbo spin echo sequences. Materials and Methods We conducted a retrospective cross-sectional study in 42 patients with a confirmed diagnosis of MS. All patients had 7 T MRI that incorporated LAMA, 3D DIR, and 2D T2-weighted turbo spin echo sequences. Three readers assessed lesion count in the brainstem, cerebellum, and upper cervical spinal cord using both DIR and T2-weighted images in one session. In a separate session, LAMA was analyzed alone. Contrast-to-noise ratio was also compared between LAMA and the conventional sequences. Lesion counts between methods were assessed using nonparametric Wilcoxon signed rank test. Interrater agreement in lesion detection was estimated by intraclass correlation coefficients. Results LAMA identified a significantly greater number of lesions than DIR + T2 (mean 6.4 vs 3.0; P < 0.001). LAMA also exhibited better interrater agreement (intraclass correlation coefficient [95% confidence interval], 0.75 [0.41–0.88] vs 0.61 [0.35–0.78]). The contrast-to-noise ratio for LAMA (3.7 ± 0.9) significantly exceeded that of DIR (1.94 ± 0.7) and T2 (1.2 ± 0.7) (all P 's < 0.001). In cases with no lesions detected using DIR + T2, at least 1 lesion was identified in 83.3% with LAMA. Across all analyzed brain regions, LAMA consistently detected more lesions than DIR + T2. Conclusions LAMA significantly improves the detection of infratentorial demyelinating lesions in MS patients compared with traditional methods. Integrating LAMA with standard magnetization-prepared 2 rapid acquisition gradient echo acquisition provides a valuable tool for accurately characterizing the extent of MS disease.
Year:
2024
Year:
2024
Layer fMRI is an increasingly utilized technique that provides insights into the laminar organization of brain activity. However, both blood-oxygen-level-dependent (BOLD) fMRI and vascular space occupancy data (VASO) have certain limitations, such as bias towards larger cortical veins in BOLD fMRI and high specific absorption rate in VASO. This study aims to explore the feasibility of whole-brain laminar functional quantitative susceptibility mapping (fQSM) compared to laminar BOLD fMRI and VASO at ultra-high field. Data were acquired using 3D EPI techniques. Complex data were denoised with NORDIC and susceptibility maps were computed using 3D path-based unwrapping, the variable-kernel sophisticated harmonic artifact reduction as well as the streaking artifact reduction for QSM algorithms. To assess layer-specific activation, twenty layers were segmented in the somatosensory and motor cortices, obtained from a finger tapping paradigm, and further averaged into six anatomical cortical layers. The magnitude of signal change and z-scores were compared across layers for each technique. fQSM showed the largest activation-dependent mean susceptibility decrease in Layers II/III in M1 and Layers I/ II in S1 with up to -1.3 ppb while BOLD fMRI showed the strongest mean signal increase in Layer I. Our data suggest that fQSM demonstrates less bias towards activation in superficial layers compared to BOLD fMRI. Moreover, activation-based susceptibility change was comparable to VASO data. Studying whole-brain, layer-dependent activation with submillimeter fQSM is feasible, and reduces bias towards venous drainage effects on the cortical surface compared to BOLD fMRI, thereby enabling better localization of laminar activation.
Year:
2024
Year:
2023
Collaborators (11)
Yi Wang
Weill Cornell Medical College
Jongho Lee
Professor
Seoul National University
Zungho Zun
Assistant Professor
Weill Cornell Medicine
Pascal Spincemaille
Associate Professor of Physics Research in Radiology
Weill Cornell Medical College
Michael Orth
Associate Professor
University of Bern
Erik Middlebrooks
Professor & Consultant
Mayo Clinic
Xu Li
Associate Professor
Johns Hopkins University School of Medicine
Mauro Costagli
Ricercatore Convenzionato
Ospedale Policlinico San Martino
Philip W Tipton
Associate Professor
University of Tennessee
Chunlei Liu
Associate Professor
University of California, Berkeley
Martin Prince
Professor
Columbia University Vagelos College of Physicians and Surgeons
Make your next move.
Prepare your application
Review drafts before you send them.