Tao Gu

Has grant

Macquarie University
Country flagAustralia

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Recent Grants

Grant: Close

Decimetre-level indoor positioning on Wi-Fi

Open Date: 2019-01-01

Close Date: 2021-12-31

Grant: Close

Non-intrusive human activity sensing with radio signals

Open Date: 2018-01-01

Close Date: 2020-12-31

Grant: Close

Wireless Sensor Network for Long-term Monitoring of Urban Microclimate

Open Date: 2012-02-02

Close Date:

Grant: Close

On-demand, Real-time Classification and Advanced Event Detection over Multiple Sensory Data Streams

Open Date: 2009-12-07

Close Date:

Articles (17)

Year:

2024

Year:

2024

Year:

2024

Year:

2023

Electrocardiogram (ECG) monitoring has been widely explored in detecting and diagnosing cardiovascular diseases due to its accuracy, simplicity, and sensitivity. However, medical- or commercial-grade ECG monitoring devices can be costly for people who want to monitor their ECG on a daily basis. These devices typically require several electrodes to be attached to the human body which is inconvenient for continuous monitoring. To enable low-cost measurement of ECG signals with off-the-shelf devices on a daily basis, in this paper, we propose a novel ECG sensing system that uses acceleration data collected from a smartphone. Our system offers several advantages over previous systems, including low cost, ease of use, location and user independence, and high accuracy. We design a two-tiered denoising process, comprising SWT and Soft-Thresholding, to effectively eliminate interference caused by respiration, body, and hand movements. Finally, we develop a multi-level deep learning recovery model to achieve efficient, real-time and user-independent ECG measurement on commercial mobile phones. We conduct extensive experiments with 30 participants (with nearly 36,000 heartbeat samples) under a user-independent scenario. The average errors of the PR interval, QRS interval, QT interval, and RR interval are 12.02 ms, 16.9 ms, 16.64 ms, and 1.84 ms, respectively. As a case study, we also demonstrate the strong capability of our system in signal recovery for patients with common heart diseases, including tachycardia, bradycardia, arrhythmia, unstable angina, and myocardial infarction.

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Collaborators (6)

Yu Zhang

Macquarie University

AUSTRALIA
View details

Ke Sun

Assistant Professor

University of Michigan

UNITED STATES
View details

Dalin Zhang

Aalborg University

DENMARK
View details

Tao Gu

Macquarie University

AUSTRALIA
View details

Zhenguo Shi

Macquarie University

AUSTRALIA
View details

Ningning HOU

Macquarie University

AUSTRALIA
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.