Wesley Culberson

Associate Professor

University of Wisconsin-Madison
Country flagUnited States

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

About

Wesley Culberson is an Associate Professor at UW–Madison, United States. His research areas include radiation dosimetry, electron irradiation, and proton therapy techniques, focusing on enhancing treatment accuracy and patient safety. Recent contributions to the field encompass studies on high dose rate irradiation effects and advanced imaging methods in radiotherapy.

Articles (8)

Year:

2025

Year:

2024

Year:

2023

Background Quality assurance measurement of IMRT/VMAT treatment plans is resource intensive, and other more efficient methods to achieve the same confidence are desirable. Purpose We aimed to analyze treatment plans in the context of the treatment planning systems that created them, in order to predict which ones will fail a standard quality assurance measurement. To do so, we sought to create a tool external to the treatment planning system that could analyze a set of MLC positions and provide information that could be used to calculate various evaluation metrics. Methods The tool was created in Python to read in DICOM plan files and determine the beam fluence fraction incident on each of seven different zones, each classified based on the RayStation MLC model. The fractions, termed grid point fractions, were validated by analyzing simple test plans. The average grid point fractions, over all control points for 46 plans were then computed. These values were then compared with gamma analysis pass percentages and median dose differences to determine if any significant correlations existed. Results Significant correlation was found between the grid point fraction metrics and median dose differences, but not with gamma analysis pass percentages. Correlations were positive or negative, suggesting differing model parameter value sensitivities, as well as potential insight into the treatment planning system dose model. Conclusions By decomposing MLC control points into different transmission zones, it is possible to create a metric that predicts whether the analyzed plan will pass a quality assurance measurement from a dose calculation accuracy standpoint. The tool and metrics developed in this work have potential applications in comparing clinical beam models or identifying their weak points. Implementing the tool within a treatment planning system would also provide more potential plan optimization parameters.

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2020

Collaborators (2)

Daniel Hyer

Associate Professor

Iowa State University

UNITED STATES
View details

Sean P. Frigo

-

UNITED STATES
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.