Daniel Hyer
Has grant
Associate Professor
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Daniel Hyer is an Associate Professor at the University of Iowa, USA. His research interests focus on advanced radiation therapy techniques, medical imaging, and treatment methodologies for cancer, particularly in prostate and melanoma patients. Recent publications include studies on MR-guided radiation therapy and innovative proton therapy approaches. He is dedicated to improving clinical outcomes and prognostication in oncology patients.
Recent Grants
Grant: Close
Optimization and evaluation of new motion monitoring image sequences on the Unity
Open Date: 2022-09-01
Close Date: 2023-08-01
Grant: Close
Usability evaluation and algorithms performance review for the Unity gating solution
Open Date: 2021-05-01
Close Date: 2022-08-01
Grant: Close
Evaluate treatment planning improvements for the Unity System using Research Monaco
Open Date: 2020-11-01
Close Date: 2021-11-01
Grant: Close
Sharpening the edge in pencil-beam proton therapy: an aftermarket collimation system to better spare normal tissue during radiation treatment
Open Date: 2018-09-01
Close Date: 2025-08-01
Grant: Close
Dynamic Collimation System
Open Date: 2014-07-01
Close Date: 2015-11-01
Articles (27)
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
The Elekta Unity magnetic resonance (MR) linac is limited to longitudinal couch motion and a sagittal‐only laser, which restricts the ability to perform patient‐specific quality assurance (PSQA) intensity‐modulated radiotherapy (IMRT) measurements for very lateral targets. This work introduces a simple method to perform PSQA using the Sun Nuclear ArcCheck‐MR phantom at left and right lateral positions without additional equipment or in‐house construction. The proposed setup places the center of the phantom 1.3 cm vertical and 12.9 cm lateral to isocenter in either the left or right direction. Computed tomography (CT) scans are used to simulate the setup and create a QA plan template in the Monaco treatment planning system (TPS). The workflow is demonstrated for four patients, with an average axial distance from the center of the bore to the planning target volume (PTV) of 12.4 cm. Gamma pass rates were above 94% for all plans using global 3%/2 mm gamma criterion with a 10% threshold. Setup uncertainties are slightly larger for the proposed lateral setup compared to the centered setup on the Elekta platform (∼1 mm compared to ∼0.5 mm), but acceptable pass rates are achievable without optimizing shifts in the gamma analysis software. In general, adding the left and right lateral positions increases the axial area in the bore encompassed by the cylindrical measurement array by 147%, substantially increasing the flexibility of measurements for offset targets. Based on this work, we propose using the lateral QA setup if the closest distance to the PTV edge from isocenter is larger than the array radius (10.5 cm) or the percent of the PTV encompassed by the diode array would be increased with the lateral setup compared to the centered setup.
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Collaborators (9)
Jui-Kai Wang
Assistant Professor
University of Texas Southwestern Medical Center
John Buatti
Professor and Chair
The University of Iowa
Wesley Culberson
Associate Professor
University of Wisconsin-Madison
Mohammed Milhem
Oncology Section Chief
University of Iowa Healthcare
Margaret Kozak
Assistant Professor
The University of Iowa
Isabella Grumbach
Iowa State University
Martin Fast
Universitair Medisch Centrum Utrecht
Joel J. St‐Aubin
-
Mona Garvin
Iowa State University
Make your next move.
Prepare your application
Review drafts before you send them.