Your Twin learns with you

30% off annual Pro20% off monthly Pro

Ends in00h00m00s

David Bark

Has grant

Associate Professor

MONASH UNIVERSITY
Country flagAustralia

Research Interests

Explore related searches

Recent Grants

Grant: Close

Paper-based high shear hemostatic analytical device

Open Date: 2023-07-01

Close Date: 2026-04-30

Grant: Open

Impact of turbulence on blood in mechanical circulatory support

Open Date: 2022-07-01

Close Date: 2027-06-30

Grant: Close

Biomechanical Thromboinflammatory Microvascular Obstruction in Reperfusion Injury

Open Date: 2018-07-01

Close Date: 2021-06-30

Grant: Close

Cytoskeletal Mechanical Transduction of Force in Platelets Attaching in Flow

Open Date: 2018-05-01

Close Date: 2021-01-31

Grant: Close

Biomechanical Response of Platelets to Superhydrophobic Surface in Mechanical Heart Valves and Other Blood-Contacting Medical Devices

Open Date: 2015-09-10

Close Date: 2016-12-31

Articles (8)

Year:

2026

Year:

2026

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Introduction Although mechanical circulatory support saved many lives during the last decade, clinical observations have shown that the continuous flow pumps are associated with a much higher incidence of gastrointestinal bleeding and kidney problems, among others, compared with the earlier generation pulsatile pumps. However, the presence of several moving mechanical components made pulsatile pumps less durable, bulky, and prone to malfunction, ultimately leading to bias in favor of continuous flow designs. Objective The aim of the current work is to create a prototype tubular pulsatile pump and to test the timing of the pump in a left heart simulator. Methods A left heart simulator to mimic pumping from a failing heart was created. This was used to experimentally test the output of a prototype ventricular assist device relative to a failing heart in the form of flow and pressure. The effect of pulsation timing was quantified. Results A failing heart was simulated with an average flow rate of 1.1 L/min and a systolic pressure of 47 mm Hg. With the pump, the flow rate increases to 4.8 L/min and a systolic pressure of 110 mm Hg, in a copulsation mode, while activating for 300–400 ms. If the activation time is reduced, or increased, the pump becomes less effective. Load on the heart is reduced when the pump operates in a counterpulsation mode. Conclusion A pulsatile pump, like the one proposed, provides adequate output for mechanical circulatory support, while minimizing the number of moving parts that could otherwise lead to tribological wear.

Year:

2022

Collaborators (9)

Kimberly A. Thomas

-

UNITED STATES
View details

Frederik Denorme

tenure track asst. professor

University of Antwerp

BELGIUM
View details

Philip Spinella

Professor of Surgery and Critical Care Medicine

University of Pittsburgh

UNITED STATES
View details

Éric Boilard

Centre de recherche du CHU de Québec-Université Laval

CANADA
View details

Laura Heitsch

Associate Professor

Washington University in St. Louis

UNITED STATES
View details

Edon Rabinowitz

Assistant Professor, Pediatrics, Divisions of Cardiology & Critical Care Medicine

Washington University in St. Louis

UNITED STATES
View details

Susan Shea

Assistant Professor

University of Pittsburgh

UNITED STATES
View details

Irina Portier

Washington University in St. Louis

UNITED STATES
View details

Elizabeth Gardiner

Professor and Head of Department

Australian National University

AUSTRALIA
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.