Meet ApplyKite Twin, the application assistant that learns with you
Meet your Twin, it learns with you
Your Twin learns with you
Launch week codes:30% off annual Pro20% off monthly Pro
Ends in00h00m00s
Ends in00h00m00s
David Bark
Has grant
Associate Professor
Research Interests
Explore related searches
Recent Grants
Grant: Close
Paper-based high shear hemostatic analytical device
Open Date: 2023-07-01
Close Date: 2026-04-30
Grant: Open
Impact of turbulence on blood in mechanical circulatory support
Open Date: 2022-07-01
Close Date: 2027-06-30
Grant: Close
Biomechanical Thromboinflammatory Microvascular Obstruction in Reperfusion Injury
Open Date: 2018-07-01
Close Date: 2021-06-30
Grant: Close
Cytoskeletal Mechanical Transduction of Force in Platelets Attaching in Flow
Open Date: 2018-05-01
Close Date: 2021-01-31
Grant: Close
Biomechanical Response of Platelets to Superhydrophobic Surface in Mechanical Heart Valves and Other Blood-Contacting Medical Devices
Open Date: 2015-09-10
Close Date: 2016-12-31
Articles (8)
Year:
2026
Year:
2026
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Introduction Although mechanical circulatory support saved many lives during the last decade, clinical observations have shown that the continuous flow pumps are associated with a much higher incidence of gastrointestinal bleeding and kidney problems, among others, compared with the earlier generation pulsatile pumps. However, the presence of several moving mechanical components made pulsatile pumps less durable, bulky, and prone to malfunction, ultimately leading to bias in favor of continuous flow designs. Objective The aim of the current work is to create a prototype tubular pulsatile pump and to test the timing of the pump in a left heart simulator. Methods A left heart simulator to mimic pumping from a failing heart was created. This was used to experimentally test the output of a prototype ventricular assist device relative to a failing heart in the form of flow and pressure. The effect of pulsation timing was quantified. Results A failing heart was simulated with an average flow rate of 1.1 L/min and a systolic pressure of 47 mm Hg. With the pump, the flow rate increases to 4.8 L/min and a systolic pressure of 110 mm Hg, in a copulsation mode, while activating for 300–400 ms. If the activation time is reduced, or increased, the pump becomes less effective. Load on the heart is reduced when the pump operates in a counterpulsation mode. Conclusion A pulsatile pump, like the one proposed, provides adequate output for mechanical circulatory support, while minimizing the number of moving parts that could otherwise lead to tribological wear.
Year:
2022
Collaborators (9)
Kimberly A. Thomas
-
Frederik Denorme
tenure track asst. professor
University of Antwerp
Philip Spinella
Professor of Surgery and Critical Care Medicine
University of Pittsburgh
Éric Boilard
Centre de recherche du CHU de Québec-Université Laval
Laura Heitsch
Associate Professor
Washington University in St. Louis
Edon Rabinowitz
Assistant Professor, Pediatrics, Divisions of Cardiology & Critical Care Medicine
Washington University in St. Louis
Susan Shea
Assistant Professor
University of Pittsburgh
Irina Portier
Washington University in St. Louis
Elizabeth Gardiner
Professor and Head of Department
Australian National University
Make your next move.
Prepare your application
Review drafts before you send them.