Edward M. Powers

Country flagUnited States

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (5)

Introduction Cardiac implantable electronic device infections often necessitate extraction, which can be complicated by calcified adhesions, leading to increased procedural risk and reduced efficacy. Given these challenges, intravascular lithotripsy (IVL) has been proposed as a tool for lead extraction to aid in overcoming calcification. This report presents the first reported case where shockwave IVL was successfully employed to extract a severely calcified lead system after an initial extraction attempt failed due to extensive calcification. Clinical Background A 58‐year‐old woman with a dual‐chamber pacemaker and recurrent MSSA bacteremia was found to have extensive calcification around her leads. An initial TLE attempt failed due to extensive calcifications. Intervention Three months later, given ongoing bacteremia, IVL was used during a repeat percutaneous extraction attempt. Lithotripsy pulses were applied via balloon catheter to disrupt calcified adhesions, enabling sheath advancement and lead mobilization. Results Both atrial and ventricular leads were successfully extracted without major complications. The use of IVL directly enabled success where prior methods had failed. Conclusion This is the first reported case of successful CIED lead extraction using IVL following a failed initial attempt due to severe calcification. This case illustrates IVL's potential in overcoming specific high‐risk anatomic challenges.

Year:

2025

Background In End-Stage Renal Disease (ESRD) patients, the coexistence of AF significantly elevates the risks of stroke (4.8 - 5.6 per 100 person-years) and mortality (26.9 per 100 person-years). Current AF literature lacks insights into pulmonary vein isolation (PVI) outcomes in this population. We aimed to assess the outcomes of PVI in ESRD patients with AF. Methods and Materials We included all adult patients with a pre-existing diagnosis of ESRD and at least one prior admission for AF from the United States Renal Data System (USRDS) registry and stratified them according to Pulmonary Vein Isolation (PVI). Those with prior transplantation were excluded. Kaplan-Meier curves were used for time-to-evet analysis. Logistic regression analysis was used to assess hazard ratios. Propensity score analysis was used to evaluate the treatment effect after adjusting for covariates. Results The study included 103,982 ESRD patients with AF, of whom 4,314 (4.15%) received ablation, and 99,668 (95.85%) were managed medically. After matching, there was a reduction in mortality (90.2% vs 93.4%, p<0.001) among the ablation group compared to no ablation at 5 years. Increased age (60-69 years and ≥70 years) was associated with 3-fold and 6-fold higher odds of mortality, respectively. A history of congestive heart failure increased the odds of mortality by 36%, while prior stroke, coronary disease, and cancer did not. Conclusion In ESRD patients with AF, despite a high 5-year mortality, those who undergo PVI exhibit a lower mortality rate compared to those managed without PVI.

Year:

2025

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% ( P <0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P =0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P =0.004, and odds ratio, 29.93; P <0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.

Year:

2024

Aims Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. Methods and results Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15 Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. Conclusion Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.

Year:

2024

Year:

2023

Collaborators (5)

Zachary Yoneda

Assistant Professor

Vanderbilt University Medical Center

UNITED STATES
View details

Travis D. Richardson

Assistant Professor

Vanderbilt University Medical Center

UNITED STATES
View details

Jay A. Montgomery

-

UNITED STATES
View details

Paari Dominic

-

UNITED STATES
View details

William G. Stevenson

-

UNITED STATES
View details