Zachary Yoneda

Assistant Professor

Vanderbilt University Medical Center
Country flagUnited States
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (4)

Background Genetic testing is now recommended for select patients with early-onset atrial fibrillation (AF). Hemochromatosis is an autosomal recessive syndrome that occurs in patients who carry two pathogenic or likely-pathogenic (P/LP) variants in HFE. HFE is included on some genetic testing panels used for patients with AF. Hemochromatosis causes cardiomyopathy due to iron overload in the ventricle; however, it is unknown whether AF can be an early manifestation that is identified by genetic testing. Methods A total of 347 patients were referred to a dedicated AF precision medicine clinic. The clinical diagnostic evaluation included an H&P, 12-lead ECG, ambulatory ECG monitoring, and cardiac imaging (cardiac MRI and/or TTE). Genetic testing was performed using CLIA-approved laboratories: Labcorp/Invitae, GeneDx, or Vanderbilt University Medical Center. HFE was included on the cardiomyopathy panel used by 2 of the 3 laboratories. Results HFE was tested in 165 participants (median age 46 years [IQR 35-55], 115 [70%] male, 149 [90%] White). Six participants (4%) had two pathogenic variants in HFE. All of them were C282Y/H63D compound heterozygotes. Forty-one participants (25%) were heterozygous carriers of one pathogenic HFE variant. Among the 6 participants with 2 pathogenic HFE variants, the median ferritin level was 346 mcg/L [IQR 262, 496] (normal 11.4 ms; liver iron concentration 3.4 mg/g, normal <2 mg/g). Three out of 6 participants were referred for a hematology evaluation and 2 out of 6 were started on therapeutic phlebotomy. Conclusion Genetic testing can identify patients with early-onset AF who are genetically susceptible to hemochromatosis, have evidence of iron overload, and receive early intervention with therapeutic phlebotomy. These results suggest HFE should be sequenced as part of genetic testing for early-onset AF, but larger sample sizes are needed to confirm these results.

Year:

2026

Idiopathic arrhythmias originating from the mitral and tricuspid annuli are commonly encountered in clinical practice. This review focuses on distinguishing features of ventricular arrhythmias arising from these structures and the importance of distinguishing idiopathic arrhythmias from those associated with structural heart disease. Each region along the mitral and tricuspid annuli (including the cardiac crux and para-Hisian region) is then discussed separately, with a particular emphasis on the ablation strategies and pitfalls for each. Although this review series is centred around idiopathic ventricular arrhythmias, the strategies for ablation techniques in these regions are broadly applicable.

Year:

2024

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% ( P <0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P =0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P =0.004, and odds ratio, 29.93; P <0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.

Year:

2024

Aims Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. Methods and results Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15 Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. Conclusion Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.

Year:

2024

Collaborators (6)

Dan M Roden

Professor

Vanderbilt University Medical Center

UNITED STATES
View details

Travis D. Richardson

Assistant Professor

Vanderbilt University Medical Center

UNITED STATES
View details

Jay A. Montgomery

-

UNITED STATES
View details

M. Benjamin Shoemaker

Assistant Professor

Vanderbilt University Medical Center

UNITED STATES
View details

Edward M. Powers

-

UNITED STATES
View details

William G. Stevenson

-

UNITED STATES
View details