Travis D. Richardson
Assistant Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (5)
Arrhythmias originating from the specialised cardiac conduction system and papillary muscles can occur in both structurally normal and diseased hearts. Conduction system associated arrhythmias include bundle branch re-entry, fascicular re-entry, non-re-entrant fascicular ventricular tachycardia and idiopathic ventricular fibrillation. Each type of arrhythmia requires a unique diagnostic and therapeutic approach. The papillary muscles may also be a source of ventricular arrhythmias. Ablation of papillary muscle associated arrhythmias may be difficult due to the complexities of mapping, structural abnormalities and potentially the deep location of arrhythmia foci. Tools, such as intracardiac echocardiography, can be valuable.
Year:
2025
Introduction Catheter‐based radiofrequency (RF) ablation is generally regarded as the standard approach for patients with ventricular tachycardia (VT) refractory to antiarrhythmic drug therapy and may be considered as a first‐line approach when there is a preference to avoid these agents. Patients with a history of cardiac surgery may have VT substrate inaccessible to catheter ablation due to intervening prosthetic materials or scar. Methods and Results This article describes a 55‐year‐old patient with a history of surgically repaired subvalvular aortic stenosis and subsequent valve‐sparing root replacement who presented with sustained VT. After RF ablation failed due to VT substrate “guarded” by graft material, retrograde coronary venous ethanol ablation (RCVEA) was employed to successfully treat the clinical VT. Conclusion RCVEA ablation can be useful for treating VT when conventional ablation is limited by inaccessible substrate due to prior cardiac surgery.
Year:
2024
BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% ( P <0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P =0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P =0.004, and odds ratio, 29.93; P <0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.
Year:
2024
Aims Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. Methods and results Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15 Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. Conclusion Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.
Year:
2024
Year:
2023
Collaborators (4)
Zachary Yoneda
Assistant Professor
Vanderbilt University Medical Center
Jay A. Montgomery
-
Edward M. Powers
-
William G. Stevenson
-
Make your next move.
Prepare your application
Review drafts before you send them.